4
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      High-quality nodule analysis in spheroidal graphite cast iron using X-ray micro-computed tomography

      Read this article at

      ScienceOpenPublisherDOAJ
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          This work is a continuation of the studies presented in a recent paper by the authors, where a methodology to obtain different nodule quality categories in spheroidal graphite cast iron, was proposed. In this study, an exhaustive analysis of the highest-quality graphite nodules was performed. The experimental methodology involves X-ray micro-computed tomography analysis and digital image post-processing of the high-quality graphite nodule population. Furthermore, different subpopulations were selected, following a nodular size criterion. The procedure involves the evaluation and comparison of the sphericity and compactness distributions and the distances between neighbouring nodules by using ad-hoc image processing software. The results reveal the complementary nature of the sphericity and compactness parameters, which allow classifying, with great accuracy, different nodular quality categories of spheroidal graphite cast iron. Additionally, new viewpoints about the nodular morphology study and the distribution of quality nodules in the metallic matrix was provided, which could be extended to other heterogeneous materials.

          Related collections

          Author and article information

          Journal
          Frattura ed Integrità Strutturale
          Gruppo Italiano Frattura
          01 September 2022
          : 16
          : 62
          Affiliations
          [1 ] Departamento de Ingeniería Industrial, Universidad Tecnológica Nacional-Facultad Regional Rafaela, Acuña 49, Rafaela, Santa Fe, Argentina.
          [2 ] Departamento de Ingeniería Electromecánica, Universidad Tecnológica Nacional-Facultad Regional Rafaela-CONICET, Acuña 49, Rafaela, Santa Fe, Argentina
          [3 ] Departamento de Validación de Equipos y Componentes, Instituto Nacional de Tecnología Industrial-Centro Litoral, Ruta Nacional N°34 km 227.6, Rafaela, Santa Fe, Argentina
          [4 ] INTEMA, Universidad Nacional de Mar del Plata-CONICET, Av. Colón 10850, Mar del Plata, B7606BVZ, Argentina
          Article
          8ddf04c6d2ca41f3b72aa47900466e90
          10.3221/IGF-ESIS.62.20
          25da2df0-3a4c-4a74-a914-f1b21fe9fbcd

          This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 Unported License. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/

          History
          Categories
          Mechanical engineering and machinery
          TJ1-1570
          Structural engineering (General)
          TA630-695

          Materials technology,Materials properties,Materials characterization,Engineering,Civil engineering,Mechanical engineering
          X-ray micro-tomography,Nondestructive analysis,Sphericity,Spheroidal graphite cast iron,Compactness

          Comments

          Comment on this article