7
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Virtual, augmented, and mixed reality applications in orthopedic surgery

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references10

          • Record: found
          • Abstract: not found
          • Article: not found

          Effectiveness of Virtual Reality Training in Orthopaedic Surgery

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Testing the Construct Validity of a Virtual Reality Hip Arthroscopy Simulator

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Plan in 2-D, execute in 3-D: an augmented reality solution for cup placement in total hip arthroplasty

              Reproducibly achieving proper implant alignment is a critical step in total hip arthroplasty procedures that has been shown to substantially affect patient outcome. In current practice, correct alignment of the acetabular cup is verified in C-arm x-ray images that are acquired in an anterior-posterior (AP) view. Favorable surgical outcome is, therefore, heavily dependent on the surgeon's experience in understanding the 3-D orientation of a hemispheric implant from 2-D AP projection images. This work proposes an easy to use intraoperative component planning system based on two C-arm x-ray images that are combined with 3-D augmented reality (AR) visualization that simplifies impactor and cup placement according to the planning by providing a real-time RGBD data overlay. We evaluate the feasibility of our system in a user study comprising four orthopedic surgeons at the Johns Hopkins Hospital and report errors in translation, anteversion, and abduction as low as 1.98 mm, 1.10 deg, and 0.53 deg, respectively. The promising performance of this AR solution shows that deploying this system could eliminate the need for excessive radiation, simplify the intervention, and enable reproducibly accurate placement of acetabular implants.
                Bookmark

                Author and article information

                Contributors
                (View ORCID Profile)
                Journal
                The International Journal of Medical Robotics and Computer Assisted Surgery
                Int J Med Robot
                Wiley
                1478-5951
                1478-596X
                April 2020
                April 2020
                : 16
                : 2
                Affiliations
                [1 ]Mayo Clinic Alix School of Medicine Scottsdale Arizona
                [2 ]University of Notre Dame Notre Dame Indiana
                [3 ]Department of Orthopedic SurgeryMayo Clinic Phoenix Arizona
                Article
                10.1002/rcs.2067
                31867864
                232fc555-1d0a-4c4a-b2bf-e536379cb466
                © 2020

                http://onlinelibrary.wiley.com/termsAndConditions#vor

                http://doi.wiley.com/10.1002/tdm_license_1.1

                History

                Comments

                Comment on this article