6
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Management of short clinical crowns by utilizing horizontal groove retentive technique in crown/tooth or both with different luting cements – An analysis on extracted teeth

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose:

          The aim of the present study was to compare and evaluate the retention of dislodged crowns by addition of one horizontal circumferential groove (HCG) to preparation and/or casting and with two luting cements.

          Materials and Methods:

          A total of 80 recently extracted human maxillary first molar teeth of appropriate sizes were collected and mounted in the resin blocks using surveyor. Standardized full coverage tooth preparations were prepared and impressions were obtained. Dies were prepared for casting and were then subjected to tensile loading using UTM. The data obtained was statistically analyzed.

          Results:

          Obtained values were statistically analyzed using ANOVA, STUDENT “t” TEST and BONFERRONI TEST. The results showed that the mean tensile force (TF) was in the range from 49.05 to 264.87 for group A and 255.06 to 588.60 for group B. The highest TF was recorded for subgroup 3B, whereas the lowest for subgroup 1A.

          Conclusion:

          Within the limitations of the study, it was concluded that by addition of one HCG to tooth preparation or casting and to both showed significant increase in retention, when compared to control groups. The highest retention value was obtained for sample with groove on the internal surface of crown luted with SARC.

          Related collections

          Most cited references20

          • Record: found
          • Abstract: found
          • Article: not found

          The effect of various finish line preparations on the marginal seal and occlusal seat of full crown preparations.

          The influences of the marginal design of a full crown on the occlusal seat and marginal seal of a cemented full crown restoration was examined. Under the conditions of the study, the featheredge and parallel bevel preparations demonstrated the best marginal seal, followed in order by the full shoulder, 45-degree shoulder, and finally the 90-degree shoulders with 30-degree and 45-degree bevels. With regard to seating of the restoration, the 90-degree full shoulder demonstrated the best seat, followed in order by the 45-degree shoulder, 90-degree shoulder with 45-degree bevel, featheredge, 90-degree shoulder with 30-degree bevel, chamfer with parallel bevel, and finally 90-degree shoulder with parallel bevel.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            An in vitro assessment of circumferential grooves on the retention of cement-retained implant-supported crowns.

            Crowns cemented on short implant abutments may have insufficient retention.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Factors influencing the retention of cemented gold castings

                Bookmark

                Author and article information

                Journal
                J Family Med Prim Care
                J Family Med Prim Care
                JFMPC
                Journal of Family Medicine and Primary Care
                Wolters Kluwer - Medknow (India )
                2249-4863
                2278-7135
                March 2020
                26 March 2020
                : 9
                : 3
                : 1640-1646
                Affiliations
                [1 ] Department of Prosthodontics Crown and Bridge, Proddatur, Kadapa, India
                [2 ] Department of Prosthodontics Crown and Bridge and Implantology, C.K.S. Theja Institute of Dental Sciences and Research, Tirupathi, Andhra Pradesh, India
                [3 ] Department of Prosthodontics Crown and Bridge, Army College of Dental Sciences, Secunderabad, Telangana, India
                Author notes
                Address for correspondence: Dr. J. Haritha, Department of Prosthodontics, Private Practitioner, D. No: 24/513, Vasanthapeta, Proddatur, Kadapa (Dst), Andhra Pradesh - 516 360, India. E-mail: jinkaharitha12@ 123456gmail.com
                Article
                JFMPC-9-1640
                10.4103/jfmpc.jfmpc_939_19
                7266182
                32509665
                1f07657d-5af8-40da-9138-aa8681053603
                Copyright: © 2020 Journal of Family Medicine and Primary Care

                This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.

                History
                : 24 October 2019
                : 12 February 2020
                : 20 February 2020
                Categories
                Original Article

                circumferential groove,dislodged crown,self adhesive resin cement (sarc),tensile force,universal testing machine (utm)

                Comments

                Comment on this article