1
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      The Detection of Xylazine in Tijuana, Mexico: Triangulating Drug Checking and Clinical Urine Testing Data

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Introduction:

          Xylazine is a veterinary anesthetic increasingly present alongside illicit fentanyl in the United States and Canada, presenting novel health risks. Although xylazine remains less common in the Western US, Mexican border cities serve as key trafficking hubs and may have a higher prevalence of novel substances, but surveillance there has been limited.

          Methods:

          We examined deidentified records from the Prevencasa free clinic in Tijuana, describing urine and paraphernalia testing from patients reporting using illicit opioids within the past 24 hours. Xylazine (Wisebatch and Safelife brands), fentanyl, opiate, methamphetamine, amphetamine, benzodiazepine, and nitazene test strips were used to test urine and paraphernalia samples. Paraphernalia samples were also analyzed with mass spectrometry.

          Results:

          Of n=23 participants providing urine and paraphernalia samples concurrently, 100%, 91.3%, and 69.6% reported using China White/fentanyl, methamphetamine, and tar heroin, respectively. The mean age was 41.7 years, 95.7% were male, 65.2% were unhoused, and 30.4% had skin wounds currently. Xylazine positivity in urine for the 2 strip types used was 82.6% and 65.2%. For paraphernalia testing, the xylazine positivity was 65.2% and 47.8%. Confirmatory testing of paraphernalia samples by mass spectrometry indicated a 52.2% xylazine positivity, as well as fentanyl (73.9%), fluorofentanyl (30.4%), tramadol (30.4%), and lidocaine (30.4%). Mass spectrometry suggested lidocaine triggered n=3 and n=0 false positives among the xylazine test strip types.

          Discussion:

          Xylazine is present on the US-Mexico border, requiring public health intervention. High lidocaine positivity complicates the clinical detection of xylazine via testing strips. Routine urine testing for xylazine in clinical scenarios is likely feasible, yet confirmatory urine studies are needed.

          Related collections

          Most cited references13

          • Record: found
          • Abstract: not found
          • Article: not found

          Xylazine spreads across the US: A growing component of the increasingly synthetic and polysubstance overdose crisis

            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            Rapid detection of fentanyl, fentanyl analogues, and opioids for on-site or laboratory based drug seizure screening using thermal desorption DART-MS and ion mobility spectrometry

            Fentanyl and fentanyl analogues represent a current and emerging threat in the United States as pure illicit narcotics and in mixtures with heroin. Because of their extreme potency, methods to safely and rapidly detect these compounds are of high interest. This work investigates the use of thermal desorption direct analysis in real time mass spectrometry (TD-DART-MS) and ion mobility spectrometry (IMS) as tools for the rapid and sensitive (nanogram to picograms) detection of fentanyl, 16 fentanyl analogues, and five additional opioids. Competitive ionization studies highlight that detection of these compounds in the presence of heroin is readily achievable, down to 0.1% fentanyl by mass with TD-DART-MS. With IMS, detection of nanogram levels of fentanyl in a binary fentanyl and heroin mixture is possible but can be complicated by decreased resolution in certain commercial instrument models. Modifications to the alarm windows can be used to ensure detection of fentanyl in binary mixtures. Additionally, three complex background matrices (fingerprint residue, dirt, and plasticizers) are shown to have a minimal effect of the detection of these compounds. Wipe sampling of the exterior of bags of questioned powders is shown to be a safe alternative method for field screening and identification, removing the need to handle potentially lethal amounts of material.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Management of Xylazine Withdrawal in a Hospitalized Patient: A Case Report

                Bookmark

                Author and article information

                Journal
                Journal of Addiction Medicine
                Ovid Technologies (Wolters Kluwer Health)
                1932-0620
                1935-3227
                March 20 2025
                Article
                10.1097/ADM.0000000000001474
                1ef43cc7-a9d5-4e61-bea1-2ade5a31233a
                © 2025
                History

                Comments

                Comment on this article

                scite_
                0
                0
                0
                0
                Smart Citations
                0
                0
                0
                0
                Citing PublicationsSupportingMentioningContrasting
                View Citations

                See how this article has been cited at scite.ai

                scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

                Similar content398

                Most referenced authors96