8
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Simultaneous determination of plasma creatinine, uric acid, kynurenine and tryptophan by high-performance liquid chromatography: method validation and in application to the assessment of renal function.

      1
      Biomedical chromatography : BMC
      Wiley
      creatinine, high-performance liquid chromatography, kynurenine, plasma, tryptophan, uric acid

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A high-performance liquid chromatography with ultraviolet detection method has been developed for the simultaneous determination of a set of reliable markers of renal function, including creatinine, uric acid, kynurenine and tryptophan in plasma. Separation was achieved by an Agilent HC-C18 (2) analytical column. Gradient elution and programmed wavelength detection allowed the method to be used to analyze these compounds by just one injection. The total run time was 25 min with all peaks of interest being eluted within 13 min. Good linear responses were found with correlation coefficient >0.999 for all analytes within the concentration range of the relevant levels. The recovery was: creatinine, 101 ± 1%; uric acid, 94.9 ± 3.7%; kynurenine, 100 ± 2%; and tryptophan, 92.6 ± 2.9%. Coefficients of variation within-run and between-run of all analytes were ≤2.4%. The limit of detection of the method was: creatinine, 0.1 µmol/L; uric acid, 0.05 µmol/L; kynurenine, 0.02 µmol/L; and tryptophan, 1 µmol/L. The developed method could be employed as a useful tool for the detection of chronic kidney disease, even at an early stage.

          Related collections

          Author and article information

          Journal
          Biomed Chromatogr
          Biomedical chromatography : BMC
          Wiley
          1099-0801
          0269-3879
          Mar 2015
          : 29
          : 3
          Affiliations
          [1 ] Ruijin Hospital, Shanghai Jiao Tong University School of Medicine and Shanghai Institute of Hypertension, 197 Ruijin 2nd Road, Shanghai, 200025, China.
          Article
          10.1002/bmc.3291
          25042392
          1a8d5217-c993-4145-9194-d66ab6800ae1
          Copyright © 2014 John Wiley & Sons, Ltd.
          History

          creatinine,high-performance liquid chromatography,kynurenine,plasma,tryptophan,uric acid

          Comments

          Comment on this article