      Comparação de parâmetros eletrofisiológicos das estimulações cardíacas endocárdicas septal e apical Translated title: Comparison of electrophysiological parameters of septal and apical endocardial cardiac stimulation

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          FUNDAMENTO: A estimulação endocárdica convencional do ventrículo direito (VD) ocasiona alargamento do QRS e dessincronização do miocárdio, comprometendo a função ventricular. Com a necessidade de estimulação menos deletéria, a estimulação septal do VD tem sido mais utilizada. Eventualmente têm sido relatados limiares mais altos e ondas R menores na estimulação septal. OBJETIVO: Comparar os parâmetros das estimulações apical e septal, intrapaciente, para verificar se existem diferenças que possam interferir na escolha do ponto de estimulação. MÉTODOS: Estudo prospectivo controlado. Foram incluídos 25 pacientes, com 67,2 ± 9 anos, 10 (40%) mulheres, com indicações de marca-passo por bradiarritmias. Etiologias foram degenerativa em nove (36%), coronariopatia em oito (32%), doença de Chagas em sete (28%), e valvopatia em um (4%) pacientes. Foram utilizados eletrodos de fixação ativa e avaliados os limiares de comando, impedância e onda R uni e bipolares no implante e após seis meses. RESULTADOS: A média aguda dos limiares de comando, ondas R e impedâncias unipolares/bipolares septais x apicais foram, respectivamente, 0,73x0,74V e 0,73x0,78V; 10x9,9 mV e 12,3x12,4 mV; 579x621 Ω e 611x629 Ω. Comparações entre parâmetros septais e apicais com teste t-pareado bicaudal demonstraram um P > 0,1. Após seis meses, a média dos limiares de comando, ondas R e Impedâncias unipolares/ bipolares septais x apicais foram, respectivamente, 0,5 x 0,72 V e 0,71 x 0,87 V; 11,4x9,5 mV e 12x11,2 mV; 423x426Ω e 578x550Ω, com P > 0,05, exceto comparando-se limiar de estimulação unipolar septal com apical unipolar p de 0,02. CONCLUSÃO: Utilizando comparações intrapaciente, não existem diferenças expressivas entre parâmetros eletrofisiológicos de estimulação septal e apical sendo que não há restrições para a escolha da estimulação septal em ventrículo direito.

          Translated abstract

          BACKGROUND: The conventional right ventricle (RV) endocardial pacing leads QRS widening and desynchronization myocardial compromising ventricular function. With the need for stimulation less deleterious, RV septal pacing has been used more. Eventually have been reported higher thresholds and smaller R waves in the septal stimulation. OBJECTIVE: To compare the parameters of the septal and apical stimulation, intra-patient, if there are any differences that may affect the choice of the point of stimulation. METHODS: A prospective controlled study. We included 25 patients, 67.2±9 years, 10 (40%) women with indications for pacemaker for bradyarrhythmias. Etiologies were degenerative in nine (36%), Coronary disease in eight (32%), Chagas disease in seven (28%), and valve disease in one (4%) patient. Electrodes were active fixation and assessed the thresholds of command, impedance and R wave in uniand bipolar implant and after six months. RESULTS: The average acute threshold command, R wave and impedance unipolar / bipolar septais x apicais were respectively 0.73 x 0.73V and 0,74V x 0,78V; 10 x 9,9mV and 12,3 x 12,4mV; 579 x 621Ω and 611 x 629Ω. Comparisons between parameters with septal and apical two-tailed paired t-test showed a P > 0.1. After six months, the mean control thresholds, R wave impedances and unipolar/bipolar septais x apicais were respectively 0.5V x 0 72V and 0.71V x 0,87V; 11.4 x 9,5mV and 12x11,2mV; 423x426 Ω and 578x550 Ω, with P > 0.05, except compared to unipolar pacing threshold septal apical unipolar P 0.02. CONCLUSION: Using intra-patient comparisons, no significant differences between electrophysiological parameters septal and apical pacing and there are no restrictions for choosing the right ventricular septal pacing.

          Related collections

          Most cited references24

          • Record: found
          • Abstract: not found
          • Article: not found

          Adverse effects of ventricular desynchronization induced by long-term right ventricular pacing.

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Right ventricular apical pacing: the unwanted model of cardiac stimulation?

            Despite having a huge benefit in enabling heart rate control, cardiac pacing by stimulating the right ventricular apex causes an artificial iatrogenic left bundle-branch block-like syndrome. As a result, QRS widening and cardiac wall desynchronization occurs. The problems caused by this undesirable pacemaker side effect have been ignored, as they are counteracted by the great benefit of cardiac rate correction. However, the compelling evidence about its harmful effect presented in this article cannot be disregarded and should start an attitude change toward alternate sites of ventricular pacing and preclusion of the right ventricular apex stimulation.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Estimulação ventricular direita bifocal no tratamento da miocardiopatia dilatada com insuficiência cardíaca

                Bookmark

                Author and article information

                Contributors
                Role: ND
                Role: ND
                Role: ND
                Role: ND
                Role: ND
                Role: ND
                Role: ND
                Role: ND
                Journal
                rbccv
                Brazilian Journal of Cardiovascular Surgery
                Braz. J. Cardiovasc. Surg.
                Sociedade Brasileira de Cirurgia Cardiovascular (São José do Rio Preto )
                1678-9741
                June 2012
                : 27
                : 2
                : 195-202
                Affiliations
                [1 ] Instituto Dante Pazzanese de Cardiologia Brazil
                [2 ] Instituto Dante Pazzanese de Cardiologia Brazil
                Article
                S0102-76382012000200006
                10.5935/1678-9741.20120055
                15590c7b-6792-43c1-bfba-63a531cd37e6

                http://creativecommons.org/licenses/by/4.0/

                History
                Product

                SciELO Brazil

                Self URI (journal page): http://www.scielo.br/scielo.php?script=sci_serial&pid=0102-7638&lng=en
                Categories
                CARDIAC & CARDIOVASCULAR SYSTEMS
                SURGERY

                Surgery,Cardiovascular Medicine
                Pacemaker, artificial,Bradycardia,Cardiac resynchronization therapy,Marca-Passo artificial,Bradicardia,Terapia de ressincronização cardíaca

                Comments

                Comment on this article