2
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Effect of temperature difference between manikin and wet fabric skin surfaces on clothing evaporative resistance: how much error is there?

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Clothing evaporative resistance is one of the inherent factors that impede heat exchange by sweating evaporation. It is widely used as a basic input in physiological heat strain models. Previous studies showed a large variability in clothing evaporative resistance both at intra-laboratory and inter-laboratory testing. The errors in evaporative resistance may cause severe problems in the determination of heat stress level of the wearers. In this paper, the effect of temperature difference between the manikin nude surface and wet textile skin surface on clothing evaporative resistance was investigated by both theoretical analysis and thermal manikin measurements. It was found that the temperature difference between the skin surface and the manikin nude surface could lead to an error of up to 35.9% in evaporative resistance of the boundary air layer. Similarly, this temperature difference could also introduce an error of up to 23.7% in the real clothing total evaporative resistance (R ( et_real ) < 0.1287 kPa m(2)/W). Finally, it is evident that one major error in the calculation of evaporative resistance comes from the use of the manikin surface temperature instead of the wet textile fabric skin temperature.

          Related collections

          Author and article information

          Journal
          Int J Biometeorol
          International journal of biometeorology
          Springer Nature America, Inc
          1432-1254
          0020-7128
          Jan 2012
          : 56
          : 1
          Affiliations
          [1 ] Thermal Environment Laboratory, Division of Ergonomics and Aerosol Technology, Department of Design Sciences, Faculty of Engineering, Lund University, 221 00, Lund, Sweden. faming.wang@design.lth.se
          Article
          10.1007/s00484-011-0411-z
          21318453
          100b523d-e93e-45f4-af8c-56704c7b3f65
          History

          Comments

          Comment on this article