          Abstract

          This study aimed to introduce a three-dimensional (3D) images fusion method for preoperative simulation of aneurysm clipping. Consecutive unruptured aneurysm cases treated with surgical clipping from March 2021 to October 2023 were included. In all cases, preoperative images of plain computed tomography (CT), CT angiography, magnetic resonance imaging (MRI) 3D fluid-attenuated inversion recovery, 3D heavily T2-weighted images, and 3D rotational angiography were acquired and transported into a commercial software (Ziostation2 Plus, Ziosoft, Inc. Tokyo, Japan). The software provided 3D images of skull, arteries including aneurysms, veins, and brain tissue that were freely rotated, magnified, trimmed, and superimposed. Using the 3D images fusion method, two operators predicted clips to be used in the following surgery. The predicted clips and actually used ones were compared to give agreement scores for the following factors: (1) type of clips (simple or fenestrated), (2) shape of clips (straight, curved, angled, or bayonet), and (3) clipping strategy (single or multiple). The agreement score ranged from 0 to 3 because a score of 1 or 0 was given for agreement or disagreement on each factor. Interoperator reproducibility was also evaluated. During the study period, 44 aneurysms from 37 patients were clipped. All procedures were successfully completed, thanks to the precisely reproduced surgical corridors with the 3D images fusion method. Agreement in clip prediction was good with mean agreement score of 2.4. Interobserver reproducibility was also high with the kappa value of 0.79. The 3D images fusion method was useful for preoperative simulation of aneurysm clipping.

          Related collections

          Most cited references22

          • Record: found
          • Abstract: found
          • Article: not found

          Development of three-dimensional hollow elastic model for cerebral aneurysm clipping simulation enabling rapid and low cost prototyping.

          We developed a method for fabricating a three-dimensional hollow and elastic aneurysm model useful for surgical simulation and surgical training. In this article, we explain the hollow elastic model prototyping method and report on the effects of applying it to presurgical simulation and surgical training.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Virtual reality cerebral aneurysm clipping simulation with real-time haptic feedback.

            With the decrease in the number of cerebral aneurysms treated surgically and the increase of complexity of those treated surgically, there is a need for simulation-based tools to teach future neurosurgeons the operative techniques of aneurysm clipping.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Simulation of and training for cerebral aneurysm clipping with 3-dimensional models.

              With improvements in endovascular techniques, fewer aneurysms are treated by surgical clipping, and those aneurysms targeted for open surgery are often complex and difficult to treat. We devised a hollow, 3-dimensional (3D) model of individual cerebral aneurysms for preoperative simulation and surgical training. The methods and initial experience with this model system are presented. The 3D hollow aneurysm models of 3 retrospective and 8 prospective cases were made with a prototyping technique according to data from 3D computed tomographic angiograms of each patient. Commercially available titanium clips used in our routine surgery were applied, and the internal lumen was observed with an endoscope to confirm the patency of parent vessels. The actual surgery was performed later. In the 8 prospective cases, the clips were applied during surgery in the same direction and configuration as in the preoperative simulation. Fine adjustments were necessary in each case, and 2 patients needed additional clips to occlude the atherosclerotic aneurysmal wall. With these 3D models, it was easy for neurosurgical trainees to grasp the vascular configuration and the concept of neck occlusion. Practicing surgery with these models also improved their handling of the instruments used during aneurysm surgery, such as clips and appliers. Using the hollow 3D models to simulate clipping preoperatively, we could treat the aneurysms confidently during live surgery. These models allow easy and concrete recognition of the 3D configuration of aneurysms and parent vessels.
                Bookmark

                Author and article information

                Journal
                Neurol Med Chir (Tokyo)
                Neurol Med Chir (Tokyo)
                Neurologia medico-chirurgica
                The Japan Neurosurgical Society
                0470-8105
                1349-8029
                4 April 2024
                May 2024
                : 64
                : 5
                : 175-183
                Affiliations
                [1 ]Department of Neurosurgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan
                [2 ]Department of Radiology, Mie University Hospital, Tsu, Mie, Japan
                Author notes

                Corresponding author: Ryuta Yasuda, M.D., Ph.D.

                Department of Neurosurgery, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu, Mie 514-8507, Japan.

                e-mail: yasudar1@ 123456gmail.com

                Article
                10.2176/jns-nmc.2023-0182
                11153840
                38569917
                0febde78-546d-45ed-8a7c-a9c4434d90fd
                © 2024 The Japan Neurosurgical Society

                This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives International License.

                History
                : 9 August 2023
                : 18 December 2023
                Categories
                Original Article

                aneurysm clipping,image fusion,preoperative simulation,three-dimensional images

                Comments

                Comment on this article