      Calcium scoring using 64-slice MDCT, dual source CT and EBT: a comparative phantom study

      research-article

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose Assessment of calcium scoring (Ca-scoring) on a 64-slice multi-detector computed tomography (MDCT) scanner, a dual-source computed tomography (DSCT) scanner and an electron beam tomography (EBT) scanner with a moving cardiac phantom as a function of heart rate, slice thickness and calcium density. Methods and materials Three artificial arteries with inserted calcifications of different sizes and densities were scanned at rest (0 beats per minute) and at 50–110 beats per minute (bpm) with an interval of 10 bpm using 64-slice MDCT, DSCT and EBT. Images were reconstructed with a slice thickness of 0.6 and 3.0 mm. Agatston score, volume score and equivalent mass score were determined for each artery. A cardiac motion susceptibility (CMS) index was introduced to assess the susceptibility of Ca-scoring to heart rate. In addition, a difference (Δ) index was introduced to assess the difference of absolute Ca-scoring on MDCT and DSCT with EBT. Results Ca-score is relatively constant up to 60 bpm and starts to decrease or increase above 70 bpm, depending on scoring method, calcification density and slice thickness. EBT showed the least susceptibility to cardiac motion with the smallest average CMS-index (2.5). The average CMS-index of 64-slice MDCT (9.0) is approximately 2.5 times the average CMS-index of DSCT (3.6). The use of a smaller slice thickness decreases the CMS-index for both CT-modalities. The Δ-index for DSCT at 0.6 mm (53.2) is approximately 30% lower than the Δ-index for 64-slice MDCT at 0.6 mm (72.0). The Δ-indexes at 3.0 mm are approximately equal for both modalities (96.9 and 102.0 for 64-slice MDCT and DSCT respectively). Conclusion Ca-scoring is influenced by heart rate, slice thickness and modality used. Ca-scoring on DSCT is approximately 50% less susceptible to cardiac motion as 64-slice MDCT. DSCT offers a better approximation of absolute calcium score on EBT than 64-slice MDCT when using a smaller slice thickness. A smaller slice thickness reduces the susceptibility to cardiac motion and reduces the difference between CT-data and EBT-data. The best approximation of EBT on CT is found for DSCT with a slice thickness of 0.6 mm.

          Related collections

          Most cited references18

          • Record: found
          • Abstract: found
          • Article: not found

          Effect of HMG-CoA reductase inhibitors on coronary artery disease as assessed by electron-beam computed tomography.

          Angiographic studies of the regression of coronary artery disease are invasive and costly, and they permit only limited assessment of changes in the extent of atherosclerotic disease. Electron-beam computed tomography (CT) is noninvasive and inexpensive. The entire coronary-artery tree can be studied during a single imaging session, and the volume of coronary calcification as quantified with this technique correlates closely with the total burden of atherosclerotic plaque. We conducted a retrospective study of 149 patients (61 percent men and 39 percent women; age range, 32 to 75 years) with no history of coronary artery disease who were referred by their primary care physicians for screening electron-beam CT. All patients underwent base-line scanning and follow-up assessment after a minimum of 12 months (range, 12 to 15), and a volumetric calcium score was calculated as an estimate of the total burden of plaque. Treatment with 3-hydroxy-3-methylglutaryl coenzyme A (HMG-CoA) reductase inhibitors was begun at the discretion of the referring physician. Serial measurements of low-density lipoprotein (LDL) cholesterol were obtained, and the change in the calcium-volume score was correlated with average LDL cholesterol levels. One hundred five patients (70 percent) received treatment with HMG-CoA reductase inhibitors, and 44 patients (30 percent) did not. At follow-up, a net reduction in the calcium-volume score was observed only in the 65 treated patients whose final LDL cholesterol levels were less than 120 mg per deciliter (3.10 mmol per liter) (mean [+/-SD] change in the score, -7+/-23 percent; P=0.01). Untreated patients had an average LDL cholesterol level of at least 120 mg per deciliter and at the time of follow-up had a significant net increase in mean calcium-volume score (mean change, +52+/-36 percent; P<0.001). The 40 treated patients who had average LDL cholesterol levels of at least 120 mg per deciliter had a measurable increase in mean calcium-volume score (25+/-22 percent, P<0.001), although it was smaller than the increase in the untreated patients. The extent to which the volume of atherosclerotic plaque decreased, stabilized, or increased was directly related to treatment with HMG-CoA reductase inhibitors and the resulting serum LDL cholesterol levels. These changes can be determined noninvasively by electron-beam CT and quantified with use of a calcium-volume score.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Evidence for lower variability of coronary artery calcium mineral mass measurements by multi-detector computed tomography in a community-based cohort--consequences for progression studies.

            To compare the measurement variability for coronary artery calcium (CAC) measurements using mineral mass compared with a modified Agatston score (AS) or volume score (VS) with multi-detector CT (MDCT) scanning, and to estimate the potential impact of these methods on the design of CAC progression studies. We studied 162 consecutive subjects (83 women, 79 men, mean age 51 +/- 11 years) from a general Caucasian community-based cohort (Framingham Heart Study) with duplicate runs of prospective electrocardiographically-triggered MDCT scanning. Each scan was independently evaluated for the presence of CAC by four experienced observers who determined a "modified" AS, VS and mineral mass. Of the 162 subjects, CAC was detected in both scans in 69 (42%) and no CAC was detected in either scan in 72 (45%). Calcium scores were low in the 21/162 subjects (12%) for whom CAC was present in one but not the other scan (modified AS 0.96). However, the mean interscan variability was significantly different between mineral mass, modified AS, and VS (coefficient of variation 26 +/- 19%, 41 +/- 28% and 34 +/- 25%, respectively; p < 0.04), with significantly smaller mean differences in pair-wise comparisons for mineral mass compared with modified AS (p < 0.002) or with VS (p < 0.03). The amount of CAC but not heart rate was an independent predictor of interscan variability (r = -0.638, -0.614 and -0.577 for AS, VS, and mineral mass, respectively; all p < 0.0001). The decreased interscan variability of mineral mass would allow a sample size reduction of 5.5% compared with modified AS for observational studies of CAC progression and for randomized clinical trials. There is significantly reduced interscan variability of CAC measurements with mineral mass compared with the modified AS or VS. However, the measurement variability of all quantification methods is predicted by the amount of CAC and is inversely correlated to the extent of partial volume artifacts. Moreover, the improvement of measurement reproducibility leads to a modest reduction in sample size for observational epidemiological studies or randomized clinical trials to assess the progression of CAC.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Rates of progression of coronary calcium by electron beam tomography.

              In this study, we sought to determine the rate of progression of atherosclerosis using coronary calcium scores derived from electron beam tomography (EBT). We studied a variety of disease states (hypertension, high cholesterol, tobacco use, diabetes mellitus) followed for 1 to 6.5 years. We evaluated 299 asymptomatic persons (227 men and 72 women) who underwent 2 consecutive EBT scans at least 12 months apart. The average change in the calcium score (Agatston method) for the entire group was 33.2 +/- 9.2%/year. The treated group (receiving statins) demonstrated an average increase in calcium scores of 15 +/- 8%/year compared with 39 +/- 12%/year for untreated patients (p 10 on repeat study. In this study, statin therapy induced a 61% reduction in the rate of coronary calcium progression. This study demonstrates that EBT may be a useful tool in assessing efficacy of different interventions to retard progression of atherosclerosis, noninvasively, over relatively short time periods.
                Bookmark

                Author and article information

                Contributors
                m.j.w.greuter@rad.umcg.nl
                Journal
                Int J Cardiovasc Imaging
                The International Journal of Cardiovascular Imaging
                Springer Netherlands (Dordrecht )
                1569-5794
                1875-8312
                23 November 2007
                June 2008
                : 24
                : 5
                : 547-556
                Affiliations
                [1 ]Department of Radiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
                [2 ]Siemens Medical Solutions, Forchheim, Germany
                [3 ]Department of Cardiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
                Article
                9282
                10.1007/s10554-007-9282-0
                2373860
                18038190
                0f556f9f-85c2-485e-a708-0fcc0c1209e1
                © The Author(s) 2007
                History
                : 11 October 2007
                : 5 November 2007
                Categories
                Original Paper
                Custom metadata
                © Springer Science+Business Media, B.V. 2008

                Cardiovascular Medicine
                heart rate,dual source ct,64-slice mdct,calcium score,electron beam ct
                Cardiovascular Medicine
                heart rate, dual source ct, 64-slice mdct, calcium score, electron beam ct

                Comments

                Comment on this article

                scite_
                0
                0
                0
                0
                Smart Citations
                0
                0
                0
                0
                Citing PublicationsSupportingMentioningContrasting
                View Citations

                See how this article has been cited at scite.ai

                scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

                Similar content574

                Cited by29

                Most referenced authors485