      Transcatheter Aortic Valve Replacement for Sutureless Bioprosthetic Valve Tilting Resulting in Severe Paravalvular Leak

      case-report

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Severe paravalvular leak (PVL) may be complicated by heart failure and haemolysis. PVL management is challenging, especially when the gap is large. We describe a case of PVL due to tilting of a sutureless biological prosthesis successfully treated by transcatheter aortic valve replacement (TAV-in-SAV).

          Graphical abstract

          Related collections

          Most cited references8

          • Record: found
          • Abstract: found
          • Article: not found

          Impact of paravalvular regurgitation on the mid-term outcome after transcatheter and surgical aortic valve replacement

          The aim of this study was to evaluate the incidence and prognostic impact of paravalvular regurgitation (PVR) on the outcome after transcatheter (TAVR) and surgical aortic valve replacement (SAVR) for aortic stenosis. The nationwide FinnValve registry included data on 6463 consecutive patients who underwent TAVR (n = 2130) or SAVR (n = 4333) with a bioprosthesis for the treatment of aortic stenosis during 2008–2017. The impact of PVR at discharge after TAVR and SAVR on 4-year mortality was herein investigated. The rate of mild PVR was 21.7% after TAVR and 5.2% after SAVR. The rate of moderate-to-severe PVR was 3.7% after TAVR and 0.7% after SAVR. After TAVR, 4-year survival was 69.0% in patients with none-to-trace PVR, 54.2% with mild PVR [adjusted hazard ratio (HR) 1.64, 95% confidence interval (CI) 1.35–1.99] and 48.9% with moderate-to-severe PVR (adjusted HR 1.61, 95% CI 1.10–2.35). Freedom from PVR-related reinterventions was 100% for none-to-mild PVR and 95.2% for moderate-to-severe PVR. After SAVR, mild PVR (4-year survival 78.9%; adjusted HR 1.29, 95% CI 0.93–1.78) and moderate-to-severe PVR (4-year survival 67.8%; adjusted HR 1.36, 95% CI 0.72–2.58) were associated with worse 4-year survival compared to none-to-trace PVR (4-year survival 83.7%), but the difference did not reach statistical significance in multivariable analysis. Freedom from PVR-related reinterventions was 99.5% for none-to-trace PVR patients, 97.9% for mild PVR patients and 77.0% for moderate-to-severe PVR patients. This multicentre study showed that both mild and moderate-to-severe PVR were independent predictors of worse survival after TAVR. Mild and moderate-to-severe PVR are not frequent after SAVR, but tend to decrease survival also in these patients. ClinicalTrials.gov Identifier: NCT03385915.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Sutureless aortic valve replacement in patients who have bicuspid aortic valve.

            Bicuspid aortic valve (BAV) is generally considered to be a contraindication to sutureless aortic valve replacement (AVR). The aim of this study was to evaluate the feasibility and perioperative outcomes of this technique in patients with BAV.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Treatment of late paravalvular regurgitation after transcatheter aortic valve implantation: prognostic implications

              Paravalvular regurgitation (PVR) after transcatheter aortic valve implantation (TAVI) is associated with increased morbidity and mortality. The effect of transcatheter interventions to treat PVR after the index TAVI was investigated. A registry of consecutive patients who underwent transcatheter intervention for ≥ moderate PVR after the index TAVI at 22 centers. The principal outcomes were residual aortic regurgitation (AR) and mortality at 1 year after PVR treatment. A total of 201 patients were identified: 87 (43%) underwent redo-TAVI, 79 (39%) plug closure, and 35 (18%) balloon valvuloplasty. Median TAVI-to-re-intervention time was 207 (35; 765) days. The failed valve was self-expanding in 129 (63.9%) patients. The most frequent devices utilized were a Sapien 3 valve for redo-TAVI (55, 64%), an AVP II as plug (33, 42%), and a True balloon for valvuloplasty (20, 56%). At 30 days, AR ≥ moderate persisted in 33 (17.4%) patients: 8 (9.9%) after redo-TAVI, 18 (25.9%) after plug, and 7 (21.9%) after valvuloplasty (P = 0.036). Overall mortality was 10 (5.0%) at 30 days and 29 (14.4%) at 1 year: 0, 8 (10.1%), and 2 (5.7%) at 30 days (P = 0.010) and 11 (12.6%), 14 (17.7%), and 4 (11.4%) at 1 year (P = 0.418), after redo-TAVI, plug, and valvuloplasty, respectively. Regardless of treatment strategy, patients in whom AR was reduced to ≤ mild had lower mortality at 1 year compared with those with AR persisting ≥ moderate [11 (8.0%) vs. 6 (21.4%); P = 0.007]. This study describes the efficacy of transcatheter treatments for PVR after TAVI. Patients in whom PVR was successfully reduced had better prognosis. The selection of patients and the optimal PVR treatment modality require further investigation.
                Bookmark

                Author and article information

                Contributors
                Journal
                JACC Case Rep
                JACC Case Rep
                JACC Case Reports
                Elsevier
                2666-0849
                23 February 2024
                03 April 2024
                23 February 2024
                : 29
                : 7
                : 102270
                Affiliations
                [a ]Institut Cardiovasculaire Paris-Sud, Hôpital Jacques Cartier, Ramsay-Santé, Massy, France
                [b ]Hôpital Privé Parly 2, Ramsay-Santé, Le Chesnay, France
                Author notes
                [] Address for correspondence: Dr Philippe Garot, Institut Cardiovasculaire Paris-Sud (ICPS), Hôpital Jacques Cartier, 6 avenue du Noyer Lambert, 91300 Massy, France. p.garot@ 123456angio-icps.com
                Article
                S2666-0849(24)00051-2 102270
                10.1016/j.jaccas.2024.102270
                11031669
                38645286
                0ecfd9c0-f1eb-491b-8b51-578e9000a55a
                © 2024 The Authors

                This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

                History
                : 21 September 2023
                : 5 January 2024
                : 26 January 2024
                Categories
                Valvular Disease
                Case Report: Clinical Case

                cardiac ct-scan,paravalvular leak,sutureless,transcatheter aortic replacement valve