      Radiographic measurement of the distal tibiofibular syndesmosis has limited use.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Radiographs of 20 plastinated human cadaveric lower legs were obtained in 12 positions of rotation to determine the optimal parameter for reliable assessment of syndesmotic and ankle integrity, and to assess the effect of positioning of the ankle on this parameter. Three observers measured eight parameters twice after four repetitions of ankle positioning. Intraclass correlation coefficients and reproducibility were assessed. Some tibiofibular overlap was present in all radiographs in any position of rotation. The medial clear space was smaller than or equal to the superior clear space in all radiographs. Intraclass correlation coefficients of the other parameters were too weak for reliable quantitative measurements, as was shown with a mixed model analysis of variance. This resulted from the inability to reproduce ankle positioning, even under optimal laboratory circumstances. This study shows that no optimal radiographic parameter exists to assess syndesmotic integrity. Tibiofibular overlap and medial and superior clear space are the most useful, because one-sided traumatic absence of tibiofibular overlap may be an indication of syndesmotic injury, and a medial clear space larger than a superior clear space is indicative of deltoid injury. Additional quantitative measurement of all syndesmotic parameters with repeated radiographs of the ankle cannot be done reliably and therefore are of little value.

          Related collections

          Author and article information

          Journal
          Clin Orthop Relat Res
          Clinical orthopaedics and related research
          Ovid Technologies (Wolters Kluwer Health)
          0009-921X
          0009-921X
          Jun 2004
          : 423
          Affiliations
          [1 ] Department of Orthopaedics, Erasmus University Medical Centre, Rotterdam, The Netherlands.
          Article
          00003086-200406000-00037
          10.1097/01.blo.0000129152.81015.ad
          15232454
          0eca7189-6526-4952-ba2a-472a8b604de1
          History

          Comments

          Comment on this article

          scite_
          0
          0
          0
          0
          Smart Citations
          0
          0
          0
          0
          Citing PublicationsSupportingMentioningContrasting
          View Citations

          See how this article has been cited at scite.ai

          scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

          Similar content409

          Cited by56