55
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Force to Rebalance Control of HRG and Suppression of Its Errors on the Basis of FPGA

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A novel design of force to rebalance control for a hemispherical resonator gyro (HRG) based on FPGA is demonstrated in this paper. The proposed design takes advantage of the automatic gain control loop and phase lock loop configuration in the drive mode while making full use of the quadrature control loop and rebalance control loop in controlling the oscillating dynamics in the sense mode. First, the math model of HRG with inhomogeneous damping and frequency split is theoretically analyzed. In addition, the major drift mechanisms in the HRG are described and the methods that can suppress the gyro drift are mentioned. Based on the math model and drift mechanisms suppression method, four control loops are employed to realize the manipulation of the HRG by using a FPGA circuit. The reference-phase loop and amplitude control loop are used to maintain the vibration of primary mode at its natural frequency with constant amplitude. The frequency split is readily eliminated by the quadrature loop with a DC voltage feedback from the quadrature component of the node. The secondary mode response to the angle rate input is nullified by the rebalance control loop. In order to validate the effect of the digital control of HRG, experiments are carried out with a turntable. The experimental results show that the design is suitable for the control of HRG which has good linearity scale factor and bias stability.

          Related collections

          Most cited references23

          • Record: found
          • Abstract: not found
          • Conference Proceedings: not found

          Vibratory gyro analysis by the method of averaging

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            The hemispherical resonator gyro: from wineglass to the planets

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              THE INFLUENCE OF CONTROL SYSTEM DESIGN ON THE PERFORMANCE OF VIBRATORY GYROSCOPES

                Bookmark

                Author and article information

                Journal
                Sensors (Basel)
                Sensors (Basel, Switzerland)
                Molecular Diversity Preservation International (MDPI)
                1424-8220
                2011
                16 December 2011
                : 11
                : 12
                : 11761-11773
                Affiliations
                [1 ] College of Mechanical Engineering and Automation, National University of Defense Technology, Changsha 410073, Hunan, China; E-Mails: wenqiwu_lit@ 123456hotmail.com (W.W.); ruobing@ 123456nudt.edu.cn (B.L.); ly20090801@ 123456163.com (Y.L.); jqa1987@ 123456163.com (Q.J.)
                [2 ] Institution of Piezoelectric and Acousto-Optic Technology, Chongqing 400060, China; E-Mail: hrg@ 123456sipat.com
                Author notes
                [* ] Author to whom correspondence should be addressed; E-Mail: wangxu-lit@ 123456163.com ; Tel.: +86-731-8457-6463; Fax: +86-731-8457-6463.
                Article
                sensors-11-11761
                10.3390/s111211761
                3252009
                22247692
                0d1af6a8-890f-4411-ab3e-dfd40b32ab74
                © 2011 by the authors; licensee MDPI, Basel, Switzerland.

                This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license ( http://creativecommons.org/licenses/by/3.0/).

                History
                : 8 November 2011
                : 8 December 2011
                : 15 December 2011
                Categories
                Article

                Biomedical engineering
                hemispherical resonator gyro (hrg),fpga,quadrature error,rate sensor,force-to-rebalance control

                Comments

                Comment on this article