5
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      On-column deracemization of an atropisomeric biphenyl by quinine-based stationary phase and determination of rotational energy barrier by enantioselective stopped-flow HPLC and CEC.

      1 , , ,
      Chirality
      Wiley

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The reversible enantiomerization of axially chiral 2'-dodecyloxy-6-nitrobiphenyl-2-carboxylic acid was studied in the presence of a brush type chiral stationary phase based on O-(tert-butylcarbamoyl) quinine as chiral selector unit by stopped-flow high-performance liquid chromatography (sfHPLC) and capillary electrochromatography (sfCEC). After initial separation of the enantiomers in the first section of the column, the flow was stopped and the resolved species allowed to enantiomerize on-column. From this conversion, which could be determined from the enantiomeric ratios at different enantiomerization times, kinetic rate constants were calculated. By sfHPLC at a constant temperature of 15 degrees C, kinetic rate constants in the presence of the CSP were found to be 4.1 x 10(-5) s(-1) and 2.2 x 10(-5) s(-1) for the (-) and (+)-enantiomers, respectively, corresponding to half-lives of 279 and 530 min. Thus, apparent activation energies of enantiomerization were calculated to be 93.0 and 94.6 kJ mol(-1) for the (-) and (+)-enantiomers. On the macroscopic level, the apparent difference of rotational energy barriers and kinetic rate constants for both enantiomers is reflected as deracemization. For example, starting from a racemic mixture, an enantiomeric excess (ee) of 14% was seen in the stopped-flow HPLC experiment described after an enantiomerization time of 220 min at 15 degrees C, and a maximal ee of 17% can be approximated after infinite enantiomerization time. There is good agreement between HPLC and CEC results as well as their experimental errors, confirming that the new sfCEC technique may be a valuable and convenient tool to study interconversion processes.

          Related collections

          Author and article information

          Journal
          Chirality
          Chirality
          Wiley
          0899-0042
          0899-0042
          2001
          : 13
          : 10
          Affiliations
          [1 ] Institute of Analytical Chemistry, University of Vienna, Vienna, Austria.
          Article
          10.1002/chir.10015
          10.1002/chir.10015
          11746796
          0b49a75a-4229-44c3-87b7-899f3cc66404
          History

          Comments

          Comment on this article