      Peak flux performance and microbial removal by selected membrane bioreactor systems

      , , ,
      Water Research
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A pilot study was conducted over a period of 18 months at the Point Loma Wastewater Treatment Plant (PLWWTP) in San Diego, CA to evaluate the operational and water quality performance of six selected membrane bioreactor (MBR) systems at average and peak flux operation. Each of these systems was operated at peak flux for 4 h a day for six consecutive days to assess peak flux performance. Virus seeding studies were also conducted during peak flux operation to assess the capability of these systems to reject MS-2 coliphage. When operating at steady state, these MBR systems achieved an effluent BOD concentration of <2 mg/L and a turbidity of <0.1 NTU. Peak flux for the MBR systems ranged from 56 to 76 L/m2/h (liters per square meter per hour) with peaking factors in the range of 1.5-3.2. When switching from average to peak flux operation, a reversible drop of 22-32% in temperature-corrected permeability was observed for all submerged MBR systems. The percent drop in permeability increased as MLSS concentration in the membrane tank increased from 11,100 mg/L to 15,300 mg/L and was observed to be highest for the system operating at highest MLSS concentration. Such trends were not observed with an external MBR system. Each MBR system was able to sustain a 4-h-a-day peak flow for six consecutive days with only moderate membrane fouling. The membrane fouling was quantified by measuring the drop in temperature-corrected permeability. This drop ranged from 13 to 33% over six days for different submerged MBR systems. The MBR systems achieved microbial removal in the range of 5.8-6.9 logs for total coliform bacteria, >5.5 to >6.0 logs for fecal coliform bacteria and 2.6 to >3.4 logs for indigenous MS-2 coliphages. When operating at peak flux, seeded MS-2 coliphage removal ranged from 1.0 to 4.4 logs, respectively. The higher log removal values (LRVs) for indigenous MS-2 coliphage among different MBR systems were probably the result of particle association of indigenous coliphage. Differences in membrane pore size (0.04-0.2 microm) amongst the MBR systems evaluated did not have a substantial impact on indigenous MS-2 coliphage removal, but seeded MS-2 coliphage removal varied among the different MBR systems.

          Related collections

          Author and article information

          Journal
          Water Research
          Water Research
          Elsevier BV
          00431354
          April 2010
          April 2010
          : 44
          : 8
          : 2431-2440
          Article
          10.1016/j.watres.2010.01.003
          20144839
          09cb0517-465e-4143-b426-43292fe47407
          © 2010

          https://www.elsevier.com/tdm/userlicense/1.0/

          History

          Comments

          Comment on this article