Section 1: Introduction During the past three decades, catheter and surgical ablation of atrial fibrillation (AF) have evolved from investigational procedures to their current role as effective treatment options for patients with AF. Surgical ablation of AF, using either standard, minimally invasive, or hybrid techniques, is available in most major hospitals throughout the world. Catheter ablation of AF is even more widely available, and is now the most commonly performed catheter ablation procedure. In 2007, an initial Consensus Statement on Catheter and Surgical AF Ablation was developed as a joint effort of the Heart Rhythm Society (HRS), the European Heart Rhythm Association (EHRA), and the European Cardiac Arrhythmia Society (ECAS). 1 The 2007 document was also developed in collaboration with the Society of Thoracic Surgeons (STS) and the American College of Cardiology (ACC). This Consensus Statement on Catheter and Surgical AF Ablation was rewritten in 2012 to reflect the many advances in AF ablation that had occurred in the interim. 2 The rate of advancement in the tools, techniques, and outcomes of AF ablation continue to increase as enormous research efforts are focused on the mechanisms, outcomes, and treatment of AF. For this reason, the HRS initiated an effort to rewrite and update this Consensus Statement. Reflecting both the worldwide importance of AF, as well as the worldwide performance of AF ablation, this document is the result of a joint partnership between the HRS, EHRA, ECAS, the Asia Pacific Heart Rhythm Society (APHRS), and the Latin American Society of Cardiac Stimulation and Electrophysiology (Sociedad Latinoamericana de Estimulación Cardíaca y Electrofisiología [SOLAECE]). The purpose of this 2017 Consensus Statement is to provide a state-of-the-art review of the field of catheter and surgical ablation of AF and to report the findings of a writing group, convened by these five international societies. The writing group is charged with defining the indications, techniques, and outcomes of AF ablation procedures. Included within this document are recommendations pertinent to the design of clinical trials in the field of AF ablation and the reporting of outcomes, including definitions relevant to this topic. The writing group is composed of 60 experts representing 11 organizations: HRS, EHRA, ECAS, APHRS, SOLAECE, STS, ACC, American Heart Association (AHA), Canadian Heart Rhythm Society (CHRS), Japanese Heart Rhythm Society (JHRS), and Brazilian Society of Cardiac Arrhythmias (Sociedade Brasileira de Arritmias Cardíacas [SOBRAC]). All the members of the writing group, as well as peer reviewers of the document, have provided disclosure statements for all relationships that might be perceived as real or potential conflicts of interest. All author and peer reviewer disclosure information is provided in Appendix A and Appendix B. In writing a consensus document, it is recognized that consensus does not mean that there was complete agreement among all the writing group members. Surveys of the entire writing group were used to identify areas of consensus concerning performance of AF ablation procedures and to develop recommendations concerning the indications for catheter and surgical AF ablation. These recommendations were systematically balloted by the 60 writing group members and were approved by a minimum of 80% of these members. The recommendations were also subject to a 1-month public comment period. Each partnering and collaborating organization then officially reviewed, commented on, edited, and endorsed the final document and recommendations. The grading system for indication of class of evidence level was adapted based on that used by the ACC and the AHA. 3,4 It is important to state, however, that this document is not a guideline. The indications for catheter and surgical ablation of AF, as well as recommendations for procedure performance, are presented with a Class and Level of Evidence (LOE) to be consistent with what the reader is familiar with seeing in guideline statements. A Class I recommendation means that the benefits of the AF ablation procedure markedly exceed the risks, and that AF ablation should be performed; a Class IIa recommendation means that the benefits of an AF ablation procedure exceed the risks, and that it is reasonable to perform AF ablation; a Class IIb recommendation means that the benefit of AF ablation is greater or equal to the risks, and that AF ablation may be considered; and a Class III recommendation means that AF ablation is of no proven benefit and is not recommended. The writing group reviewed and ranked evidence supporting current recommendations with the weight of evidence ranked as Level A if the data were derived from high-quality evidence from more than one randomized clinical trial, meta-analyses of high-quality randomized clinical trials, or one or more randomized clinical trials corroborated by high-quality registry studies. The writing group ranked available evidence as Level B-R when there was moderate-quality evidence from one or more randomized clinical trials, or meta-analyses of moderate-quality randomized clinical trials. Level B-NR was used to denote moderate-quality evidence from one or more well-designed, well-executed nonrandomized studies, observational studies, or registry studies. This designation was also used to denote moderate-quality evidence from meta-analyses of such studies. Evidence was ranked as Level C-LD when the primary source of the recommendation was randomized or nonrandomized observational or registry studies with limitations of design or execution, meta-analyses of such studies, or physiological or mechanistic studies of human subjects. Level C-EO was defined as expert opinion based on the clinical experience of the writing group. Despite a large number of authors, the participation of several societies and professional organizations, and the attempts of the group to reflect the current knowledge in the field adequately, this document is not intended as a guideline. Rather, the group would like to refer to the current guidelines on AF management for the purpose of guiding overall AF management strategies. 5,6 This consensus document is specifically focused on catheter and surgical ablation of AF, and summarizes the opinion of the writing group members based on an extensive literature review as well as their own experience. It is directed to all health care professionals who are involved in the care of patients with AF, particularly those who are caring for patients who are undergoing, or are being considered for, catheter or surgical ablation procedures for AF, and those involved in research in the field of AF ablation. This statement is not intended to recommend or promote catheter or surgical ablation of AF. Rather, the ultimate judgment regarding care of a particular patient must be made by the health care provider and the patient in light of all the circumstances presented by that patient. The main objective of this document is to improve patient care by providing a foundation of knowledge for those involved with catheter ablation of AF. A second major objective is to provide recommendations for designing clinical trials and reporting outcomes of clinical trials of AF ablation. It is recognized that this field continues to evolve rapidly. As this document was being prepared, further clinical trials of catheter and surgical ablation of AF were under way. Section 2: Definitions, Mechanisms, and Rationale for AF Ablation Definition AF is a common supraventricular arrhythmia that is characterized by rapid and irregular activation in the atria without discrete P waves on the surface electrocardiogram (ECG). AF can be diagnosed with a surface ECG, an intracardiac atrial electrogram, or both. An arrhythmia that has the ECG characteristics of AF and lasts sufficiently long for a 12-lead ECG to be recorded, or is otherwise documented to last for at least 30 seconds, should be considered to be an AF episode. The 30-second duration was selected based on previous published consensus statements and is used as the minimal duration to define recurrence of AF after catheter ablation. 1,7 This duration of AF has not been linked to a specific outcome of AF. In addition to the duration requirements listed above, the diagnosis of AF requires an ECG or rhythm strip demonstrating: (1) “absolutely” irregular R-R intervals (in the absence of complete atrioventricular [AV] block); (2) no distinct P waves on the surface ECG; and (3) an atrial cycle length (when visible) that is usually less than 200 ms. 2,7 Although there are several classification systems for AF, for this consensus document, we have adopted in large part the classification system that was presented in the 2014 AHA/ACC/HRS Guideline for the Management of Patients with Atrial Fibrillation. 5 We recommend that this classification system be used for future studies of catheter and surgical ablation of AF. Paroxysmal AF (PAF) is defined as AF that terminates spontaneously or with intervention within 7 days of onset (Table 1); persistent AF is defined as continuous AF that is sustained beyond 7 days; and long-standing persistent AF is defined as continuous AF of greater than 12 months’ duration. Early persistent AF is a new term we have defined as continuous AF of more than 7 days’ duration but less than 3 months’ duration. Within the context of AF ablation and clinical trials of AF ablation, early persistent AF defines a population of patients in whom better outcomes of AF ablation are anticipated as compared with persistent AF of more than 3 months’ duration. The term permanent AF is defined as AF in which the presence of the AF is accepted by the patient and physician, and no further attempts will be made to either restore or maintain sinus rhythm. It is important, therefore, to recognize that the term permanent AF represents a therapeutic attitude on the part of a patient and their physician rather than on any inherent pathophysiological attribute of the AF. Such decisions can change as symptoms, the efficacy of therapeutic interventions, and patient and physician preferences evolve. If a rhythm control strategy is recommended after reevaluation, the AF should be redesignated as paroxysmal, persistent, or long-standing persistent AF. Within the context of any rhythm control strategy, including catheter and surgical AF ablation, the term permanent AF is not meaningful and should not be used. Silent AF is defined as asymptomatic AF diagnosed by an opportune ECG or rhythm strip. Paroxysmal, persistent, and long-standing persistent AF can be silent. We recognize that a particular patient might have AF episodes that fall into one or more of these categories; therefore, we recommended that patients be categorized by their most frequent pattern of AF during the 6 months prior to performance of an ablation procedure. Lone AF is a descriptor that has been applied to younger patients without clinical or echocardiographic evidence of cardiac disease. Because the definitions are variable, the term lone AF is potentially confusing, and should not be used to describe populations of patients with AF nor to guide therapeutic decisions. 5 The term chronic AF also has variable definitions and should not be used to describe populations of patients with AF. The writing group recognizes that these definitions of AF are very broad, and that additional details should be provided when describing a population of patients undergoing AF ablation. With the increased use of implantable loop recorders (ILRs), pacemakers, and implantable cardioverter-defibrillators for rhythm diagnosis, we urge the investigators to specify the duration of time patients have spent in continuous AF prior to an ablation procedure, including the 24-hour AF burden, when data are available. The investigators should also specify whether patients undergoing AF ablation have previously failed pharmacological therapy, electrical cardioversion, catheter and/or surgical ablation. Shown in Table 1 are a series of definitions of AF types that can be used for future trials of AF ablation and in the literature to help standardize reporting of patient populations and outcomes. Demographic Profile of Patients with AF and Risk Factors for Development of AF AF is an exceedingly common age-related arrhythmia. Among people of European descent, the lifetime risk of developing AF after age 40 is 26% for men and 23% for women. 8 There are multiple risk factors for development of AF. 5,7 Some of these risk factors are modifiable, including hypertension, obesity, endurance exercise, obstructive sleep apnea (OSA), thyroid disease, and alcohol consumption, whereas many others are not. 5,7,9,10,11 Nonmodifiable risk factors include age, sex, family history, race, tall stature, and other types of heart and valvular disease. 5,7 Among the many risk factors for development of AF, age is perhaps the most powerful. 8,9 The relative risks (RRs) of AF development associated with a number of risk factors are provided in a recent systematic review. 12 It is rare to develop AF prior to age 50; and by age 80, approximately 10% of individuals are diagnosed with AF. The precise pathophysiological basis of this link between AF and age is not completely understood; however, age-related fibrosis likely plays a key role. 9 AF risk factors have also been shown to be of value in predicting progression of paroxysmal to persistent AF. 13 It is notable that many of the risk factors that have been associated with development of AF also contribute to AF progression, recurrences of AF following ablation, and complications associated with AF (e.g., stroke). Natural History of AF The concept of “AF begets AF” remains a cornerstone in the understanding of the natural history of AF progression. 14 Increasing AF burden is associated with progressive atrial remodeling and the development of atrial fibrosis, which can contribute to the long-term persistence of AF. 15 A wealth of experimental data exist regarding structural and functional atrial changes that contribute to the development, maintenance, and progression of AF. In contrast, considerably less data exist regarding the natural history of AF. 16,17 This is in large part related to the difficulty in accurately assessing the underlying burden of AF in individuals and large populations. Thus, estimates of the prevalence of clinical AF subtypes and their progression have evolved with the changes in population characteristics, associated comorbidities, and development of modern arrhythmia monitoring technology. For example, the rate of progression appears to be very low in individuals with an initial diagnosis of AF who are younger than 60 years of age and who have no concomitant heart disease. Among 97 individuals followed over three decades, 21% had an isolated AF event without further recurrence, 58% had recurrent AF, and 22% developed persistent AF. 18 Other longitudinal studies have demonstrated a much higher rate of AF progression. One recent study examined the rate of progression to persistent AF among 1219 paroxysmal patients with AF. 13 Progression to persistent AF was observed in 15% of the patients over 12 months of follow-up. Predictors of progression included age, hypertension, prior transient ischemic attack (TIA) or stroke, and chronic obstructive pulmonary disease. Similar results were reported in another recent study that examined AF progression while waiting for an AF ablation procedure. 19 Among 564 patients with PAF, 11% progressed to persistent AF during a 10-month follow-up period. In this study, heart failure (HF) and a left atrial (LA) diameter >45 mm were predictive of progression. These findings raise the possibility that the clinical progression of AF could be driven by the development of associated comorbidities as opposed to the arrhythmia itself. Moreover, recent studies using pacemaker-documented AF burden have demonstrated a more complex natural history of the arrhythmia, with persistent AF reverting to paroxysmal forms, without intervention. 20 This highlights our incomplete understanding of the natural history of clinical AF and the need for larger studies focusing on the accurate assessment of AF progression and regression. Genetic Contribution to AF It is now well recognized that AF is heritable. 21,22,23 Individuals having a first-degree relative with AF have approximately a 40% increased risk for development of AF after accounting for established clinical AF risk factors. 23 In the last decade, great progress has been made in identifying the genetic determinants of AF. Although studies of families with AF have led to the identification of mutations in a series of ion channels and molecules, these mutations are typically family-specific, rare, and do not explain a significant portion of the heritability of AF. 24 Therefore, population-based or genome-wide studies have been used to identify many AF risk loci. 25,26,27,28,29,30 The genes at these loci encode transcription factors and ion channels, and many are without a clear relation to AF at the present time. There is interest in trying to use genetics to predict the onset of AF, to stratify the risk of AF outcomes such as stroke and HF, and to identify the response to treatments including antiarrhythmic medications or catheter ablation procedures. Interestingly, a genetic risk score consisting of the top 12 loci for AF can be used to identify as much as a 5-fold gradient in the risk of AF or those at greatest risk for a stroke. 31,32 However, similar to other common diseases, the genetic risk for AF provides minimal additional predictive value after considering basic clinical risk factors such as age and sex. 33,34 Future studies will be directed at using a comprehensive panel of genetic variants to identify those at greatest risk for AF, and also to predict stroke risk and outcomes to AF therapy, including AF ablation. 35 Whether genetic testing will ultimately prove to be an important clinical marker of AF risk will become clear over time. An alternative and/or complementary strategy, which might be easier for clinicians to employ, will be the use of a clinical risk score. Genetic Determinants of Ablation Outcome Because many genetic determinants of AF have been identified, a logical question would be to ask whether genetics can help predict the outcome of an ablation procedure. 35 At the present time, however, whether genetics will help predict outcomes remains an unanswered question. Although there have been a number of studies exploring the relation between a genetic variant or single nucleotide polymorphism (SNP) and AF ablation outcome, these studies have been challenged by small sample sizes, testing of a limited number of SNPs, and variable endpoints. One recent study pooled ablation data from three different sites consisting of 991 individuals of European ancestry. 36 They tested representative SNPs at the top three loci (PITX2, ZFHX3, and KCNN3) identified for AF in genome-wide association studies and related these SNPs to ablation outcome. The primary finding was that an SNP, rs2200733, at the chromosome 4q25 or the PITX2 locus for AF was associated with a 1.4-fold increased risk of late AF recurrence. In contrast, another recent study found differing results in a large Korean population of 1068 individuals undergoing catheter ablation for AF. 37 This second study tested a similar set of SNPs, representing the PITX2, ZFHX3, and KCNN3 loci, yet they did not observe any long-term difference in AF recurrence after an ablation. It is possible that the different outcomes noted in these two studies are due to a racial difference in the genetic influence on ablation outcome, although future studies will be necessary to resolve this issue. Larger, prospective, multiethnic studies that test a comprehensive number of SNPs will be necessary before genetic data can be considered clinically useful when considering AF ablation procedures. Significance of AF AF is an important arrhythmia for many reasons. First, it is common: current estimates reveal that more than 33 million individuals worldwide have AF. 38 In the United States alone, it is estimated that between 3 and 5 million people have AF, and that by 2050 this number will exceed 8 million. 39 Second, AF increases risk of stroke by an average of 5-fold. 40 AF-related strokes are more severe than those not related to AF. 41 Third, AF increases mortality, and has been linked to an increased risk of sudden death. 42,43 Consistent with these prior studies, a recent Framingham study reported that those with recurrent or sustained AF had a higher multivariable-adjusted mortality compared with those with an isolated AF episode. 44 Fourth, AF increases the risk of HF. 45 Fifth, recent studies have linked AF with the development of dementia. 46 Finally, AF causes a wide variety of symptoms, including fatigue and reduced exercise tolerance, and significantly impairs quality of life (QOL). 47 It is notable that asymptomatic status is associated with similar (or worse) prognosis compared with symptomatic status. 48 AF is also important when considered in terms of use of health care resources and cost. In the United States, AF accounts for more than 450,000 hospitalizations yearly and has contributed to more than 99,000 deaths. 49,50 AF has been reported to increase annual health care costs by $8700 per patient, resulting in a $26 billion annual increase in U.S. health care costs. Although studies have not been performed to address the question of whether AF control with catheter ablation impacts the morbidity and mortality associated with AF, it is notable that emerging data have revealed that persistent forms of AF are associated with a significant increase in thromboembolism and death compared with PAF. 51 The morbidity and mortality associated with AF provide a rationale to maintain sinus rhythm. Given the anticipated enormous public health impact of AF, proven interventions to reduce the risk of stroke, HF, cognitive impairment, and mortality are direly needed. Large, prospective, multicenter, randomized clinical trials will help address whether sinus rhythm achieved with ablation techniques lowers morbidity and mortality compared with rate control alone or treatment with antiarrhythmic therapy. These studies will also best define the patient population that will derive the most benefit. Until the results of these types of clinical trials are available, it must be recognized that the only proven benefit of AF ablation remains the reduction of symptoms and an improvement in QOL. Relationship Between Presence and Type of AF and Symptoms During the past 15 years, multiple studies have investigated the impact of rate vs rhythm control on stroke risk and mortality. 52,53,54,55 These studies have demonstrated no difference in these endpoints. When interpreting the results of these studies, it is important to keep in mind the population of patients who were enrolled, the approach used for rhythm control, and the duration of follow-up. These studies enrolled predominantly elderly, minimally symptomatic patients with AF in whom either a rate or rhythm control strategy would be acceptable; the mean duration of follow-up was less than 4 years. The primary indication for catheter ablation is to reduce patient symptoms and improve QOL. Therefore, prior to undergoing catheter ablation, it is important to confirm that the patient’s symptoms (palpitations, fatigue, or effort intolerance) result from AF and to assess their severity. In some patients with PAF, arrhythmia-monitoring tools (e.g., transtelephonic monitoring, Holter) are useful to establish the correlation between symptoms and rhythm. In patients with persistent AF who initially appear to be asymptomatic, a reassessment of symptoms after restoration of sinus rhythm with cardioversion often reveals that the patient does in fact feel better when in sinus rhythm. Because of this observation, many experienced clinicians routinely recommend cardioversion with a reassessment of symptoms in apparently asymptomatic patients with persistent AF. If the patient is ultimately demonstrated to be symptomatic, a rhythm control strategy becomes an attractive therapeutic approach. Conversely, if there is no change in symptoms postrestoration of sinus rhythm, a rate control strategy could be preferable. Several AF ablation studies evaluated the relationship between patient characteristics and the presence of AF symptoms. 56,57,58 It is well recognized that patients’ perception of AF varies widely. One of the first studies to examine AF symptoms prior to and following ablation found that among 114 patients who underwent 7-day Holters prior to and following ablation, 38% of the patients had only symptomatic AF episodes, 57% had both symptomatic and asymptomatic episodes, and 5% of the patients had only asymptomatic episodes. Following the ablation, the percentage of patients with only asymptomatic episodes of AF increased to 37%. 56 Asymptomatic AF is more frequent in men than in women. 48,59,60 In two prospective registries and in one recent retrospective study, older age was associated with asymptomatic AF. 48,60,61 Inconsistent results have been reported for the association between asymptomatic AF and cardiac and noncardiac comorbidities. 48,59,60 Although any type of AF can be asymptomatic, asymptomatic AF is more common in patients with continuous persistent AF. 48 In approximately half of the patients with highly symptomatic AF referred for catheter ablation, asymptomatic episodes are also present. 45,50,57,62 Arrhythmia episodes are more likely to be asymptomatic following, as compared with prior to, AF ablation. Therefore, assessment of freedom from AF postablation cannot be based on freedom from symptoms alone. 63 Anatomic and Electrophysiological Features of the Atria, Coronary Sinus, and Pulmonary Veins In recent decades, the development of catheter ablation of AF and other atrial arrhythmias has made it necessary to have a sound understanding of cardiac anatomy (Figure 1). Figure 1 shows the cardiac anatomy relevant for AF ablation when viewed from the anterior (Figure 1A), right lateral (Figure 1B), left lateral (Figure 1C), and posterior projections (Figure 1D, 1E). 64 Viewed from the front, the right atrium (RA) is right and anterior, while the LA is situated to the left and mainly posteriorly, with the right pulmonary veins (PVs) adjacent to the intercaval area of the RA. 65,66 Consequently, the plane of the atrial septum lies at an angle to the sagittal plane of the body. The front of the LA and the medial wall of the RA lie just behind the aortic root, separated only by the transverse pericardial sinus. The posterior wall of the LA is just in front of the tracheal bifurcation and the esophagus, with the fibrous pericardium separating the heart from these structures. PV anatomy is highly variable between patients (Figure 2). Four distinct PV ostia are present in approximately 60% of patients, whereas variant anatomy is observed in 40% of patients undergoing ablation. 67 In approximately 80% of cases, the anterior part of the ostium of the left PVs is common, separated from the appendage by a ridge. 68,69 The most frequent type of variant anatomy is a left common PV, and the second most frequent variant anatomy is a right middle PV. Anomalous PVs can also be observed arising from the roof of the atrium. The orifices of the left PVs are located more superior than those of the right PVs. The right superior (RS) PV and the left superior (LS) PV project forward and upward, whereas the right inferior (RI) PV and the left inferior (LI) PV project backward and downward. The RSPV lies just behind the superior vena cava (SVC) or RA, and the left PVs are positioned between the left atrial appendage (LAA) and the descending aorta. Nathan and Eliakim first drew attention to the presence of sleeves of cardiac tissue that extend onto the PVs (Figure 1E). 70 Myocardial muscle fibers extend from the LA into all the PVs for 1–3 cm; the thickness of the muscular sleeve is highest at the proximal ends (1–1.5 mm), and then gradually decreases distally. 16,64,71 The orientation of the major atrial muscular bundles (e.g., Bachmann’s bundle or Crista terminalis) has been recognized from anatomical dissections, with mostly circular bundles around the ostia of the PVs, AV valves, and LAA. 72 Studies have described how premature firing from the PVs can initiate AF by interacting with tissue mechanisms, using diffusion tensor imaging (at present, in vitro). 73,74 These findings have been reproduced by cardiac magnetic resonance imaging (MRI), highlighting the very variable individual pattern of fiber orientation. 75 Future in vivo implementation (in addition to identification of fibrosis), combined with simultaneous mapping techniques, could allow individual tailoring of interruption of potential reentrant “pathways.” 76,77 The greater coronary venous system drains approximately 85% of the venous flow into the RA, with the most proximal part being called the coronary sinus (CS). The great cardiac vein ascends into the left AV groove, where it passes close to the circumflex artery and under the cover of the LAA. The juncture between the great cardiac vein and the CS is marked by the entrance of the vein of Marshall (which is typically obliterated in adults and is referred to as the ligament of Marshall), which descends along the epicardium between the LAA and the LSPV and can contain sympathetic nerves and ganglia. 78 Especially around the CS itself, muscular bundles are present that interconnect to the LA, thereby serving as additional interatrial electrical “conductors.” 79,80 PV focal firing can trigger AF or act as a rapid driver to maintain the arrhythmia. During embryological development of the heart, the location of the precursors of the conduction system is defined by the looping process of the heart tube. 81,82 Cell markers common to precursors of specialized conduction tissue derived from the heart tube have been found within myocardial sleeves. 83 The presence of P cells, transitional cells, and Purkinje cells has been demonstrated in human PVs. 84,85 PV-sleeve cardiomyocytes have discrete ion channel and action potential properties that predispose them to arrhythmogenesis. 84,85 They have small background IK1, which could favor spontaneous automaticity, 84 as could their reduced coupling to atrial tissue, a property common to pacemaking structures. 86 Other studies show susceptibility to Ca2+-dependent arrhythmia mechanisms, 87 possibly due to cells of melanocyte origin. 88 Some, but not all, studies have reported that isolated cardiomyocytes from rabbit and canine PVs show abnormal automaticity and triggered activity during manipulations that enhance Ca2+ loading. 87,88,89 These properties might explain the electrical activity within the PVs that is commonly observed after electrical disconnection of the PVs from the atrium. 90 Other studies have provided evidence to suggest that the PVs and the posterior LA are also preferred sites for reentrant arrhythmias. 90,91 One important factor could be the shorter action potential duration (APD) of the PVs vs the atrium 84 due to larger delayed-rectifier K+ currents and smaller inward Ca2+ currents in the PV. 89,92,93 In addition, PVs demonstrate conduction abnormalities that promote reentry due to abrupt changes in fiber orientation as well as Na+ channel inactivation by reduced resting potentials due to small IK1. 84 Yet another study examined the impact of increasing atrial pressure on PV activation, finding that as LA pressure was increased above 10 cm H2O, the PV–LA junction became the source of dominant rotors. 94 These observations help explain the clinical link between AF and increased atrial pressure. Several clinical studies have reported shorter refractory periods (RPs) inside PVs compared to the LA, decremental conduction inside PVs, and easy induction of PV reentry with premature stimulation from the PVs. Accordingly, rapid reentrant activity with entrainment phenomena have been described inside PVs after successful PV isolation (PVI). 95,96 Electrophysiological evaluation of the PVs using multielectrode basket catheters has revealed effective refractory period (ERP) heterogeneity and anisotropic conduction properties within the PV and at the PV–LA junction, which can provide a substrate for reentry. 97 The response of PV activity to adenosine administration in patients with PAF is more consistent with a reentrant than a focal-ectopic type of mechanism. 98,99 In addition, dominant frequency analysis points to an evolution of mechanisms in patients with AF, with PV sources becoming less predominant as AF becomes more persistent and atrial remodeling progresses. 95 Autonomic Nervous System and How It Relates to AF and AF Ablation The cardiac autonomic nervous system (ANS) can be divided into the extrinsic and intrinsic ANS. 100 The extrinsic cardiac ANS consists of sympathetic and parasympathetic components, 101,102 and includes neurons in the brain and spinal cord and nerves directed to the heart. The intrinsic ANS primarily includes thousands of autonomic neurons and nerves located in ganglionated plexi (GP), which are transitioned to the epicardial fat pads outside the heart and along the great vessels in the thorax. 100,103,104 There are 7 major GP, including 4 located in the LA around the PVs. 103,105 The ligament of Marshall, which also contains GP, plays a coordination role between the extrinsic and intrinsic ANS. 106 The GP predominantly contain parasympathetic neurons, but also sympathetic neurons. In humans, numerous autonomic nerves are located at the PV–LA junction. The nerve densities are much more pronounced within 5 mm of the PV–LA junction and are higher in the epicardial surface than in the endocardium. 107,108 These data reveal that the areas of LA endocardial surface most suitable for ANS modification are located in the immediate vicinity of the PV–LA junction. Due to close relationship of the sympathetic and parasympathetic ANS components, it is difficult to perform selective radiofrequency (RF) ablation of a particular part of the ANS, 109 and ablation of these sites can destroy both adrenergic and cholinergic nerves. In an animal model of PAF, injection of parasympathomimetics into the fat pad adjacent to the PV-atrial junctions resulted in spontaneous or easily induced sustained AF, suggesting that a hyperactive ANS can play an important role in patients with focal AF arising from the PV. 110,111 Stimulation of GP by pacing at the base of the PV can also provide a substrate of AF initiation from PV firing. 112,113 Studies have shown that the intrinsic ANS has a potential impact on acute atrial electrical remodeling induced by rapid atrial pacing. 113 Other studies have shown that synergic actions of both the sympathetic and parasympathetic neurotransmitters promote rapid PV firing in an experimental system. 114 Another study demonstrated that stimulation of the right anterior GP converts isolated premature depolarization from the RSPV into AF-inducing premature depolarizations, 115 indicating a link between GP activity and AF inducibility. The authors proposed a model of a highly integrated atrial neural network in which a GP hyperactive state could release a gradient of locally excessive concentrations of neurotransmitters that initiate AF, whereas activation of the axons can “retrogradely” excite the GP at a distance to cause the release of neurotransmitters to induce AF. Several studies have identified a link between the intrinsic cardiac nervous system and complex fractionated atrial electrograms (CFAEs) and AF triggers. 113,116 The effectiveness of catheter ablation of GP in patients with AF remains controversial. One of the major challenges has been the lack of a sensitive and specific means to localize the GP in patients. 117,118,119,120 Whereas several small studies have reported improved outcomes using an anatomically based approach to localize autonomic ganglia, these findings have not been replicated by other investigators. 121,122 A recent prospective randomized surgical AF ablation study reported no improvement of outcomes by ablation of autonomic ganglia. 123 The most commonly used approach to localize the major atrial GP is to apply high-frequency stimulation (HFS) to the presumed GP areas to elicit AV block. This method has low specificity and sensitivity because endocardial GP can be embedded in epicardial fat pads. 106,124 Some investigators have suggested that HFS mainly reveals the afferent link of the ANS, suggesting that sites eliciting vagal responses do not coincide with sites where GP clusters and efferent autonomic nerves are located. 125 Another issue is reinnervation of the ANS during follow-up. 108,114 Whether reinnervation causes recurrent AF postablation remains uncertain. One study has reported that reinnervation of the ANS in patients after RF ablation is not directly related to AF recurrence. 126 In summary, there is considerable evidence that the ANS contributes to the initiation and maintenance of AF. Whether ablation of the ANS impacts the outcomes of AF ablation remains uncertain. In the future, novel approaches for ANS modulation could increase the efficacy of AF ablation treatment. 127,128,129 Cardiac Fibrosis: Etiology and How It Relates to AF Atrial fibrosis is a common finding in patients with AF. The question of whether atrial fibrosis stems from AF itself, from AF-related risk factors, or from a specific fibrotic atrial cardiomyopathy (FACM) is under debate. 130,131,132,133,134 Recently, a subgroup of patients with recent onset persistent AF have been described with a diffuse abnormal substrate and with poor outcome after ablation. 135 There is great variability in the amount of fibrosis in patients with AF, in which some patients with PAF have massive fibrosis and some patients with persistent AF show mild fibrosis. 134,136 Some morphological studies have shown that fibrosis in humans is related to the underlying disease rather than being caused by AF. 73,137,138 The specific role of age and AF risk factors in atrial fibrosis was questioned by an autopsy study, in which only small amounts of fibrofatty tissue were described in atrial specimens from patients with a high mean CHA2DS2-VASc score of 4.3 but no AF. 139 In addition, a low correlation between risk factors and the fibrotic substrate as estimated from electroanatomic voltage mapping in patients with non-PAF has been described. 140 Similarly, cardiovascular risk factors were found to be equally distributed in various classes of LA fibrosis as described by MRI studies, and structural atrial remodeling was the same in patients with and without cardiovascular risk factors. 130 On the other hand, there is extensive evidence that many AF risk factors do substantially increase atrial fibrosis content, and that AF itself might have a profibrotic effect. 141,142,143 One study reported that elevated serum markers of collagen synthesis were associated with postsurgical AF, compared with those who stayed in sinus rhythm. 144 It is possible that the fibrotic atrial substrate could be a result of a specific FACM. 131,133,140 FACM has been described as a specific disease with various expressions, from mild, to moderate, to severe atrial fibrosis, and with a potentially progressive disease process. Consequently, AF—and other arrhythmias such as reentrant atrial tachycardia (AT) and sinus node disease—can be understood as a manifestation of the preexisting FACM. 131,133,145,146 Atrial Electrical and Structural Remodeling The pathophysiology of AF is complex, involving interaction among multiple factors, including triggers, which are responsible for AF initiation; substrate, which is necessary for AF maintenance; and perpetuators, which underlie the progression of the arrhythmia from paroxysmal to the persistent forms. 146,147 The recently published EHRA/HRS/APHRS/SOLAECE expert consensus document on atrial cardiomyopathies provides a detailed review of the important topic of atrial cardiomyopathies and their interrelationship with AF. 148 It is generally believed that some degree of structural remodeling must predate electrical remodeling. The trigger mechanisms can include focal enhanced automaticity or triggered activity. Initiation of AF can be favored by both parasympathetic and sympathetic activation, which also appear to play a role in maintaining AF. 149 However, the central mechanisms governing AF initiation and perpetuation are poorly understood, which explains in part why treatment of patients with all forms of AF, and particularly long-standing persistent AF, remains suboptimal. Although AF usually starts with paroxysmal episodes, it can evolve to a persistent form in a significant number of patients. 150 A few clinical factors have been associated with transition from paroxysmal to persistent AF. 20,151,152 The transition likely reflects progressive structural and electrophysiological remodeling in both atria, making the sources of the arrhythmia more stable by fundamental mechanisms that have been incompletely explored. 153,154,155,156 AF-Related Extracellular Matrix Remodeling Persistent AF itself leads to electrical remodeling and fibrosis of the atria. 157,158 Experimental and clinical data point to a complex pathophysiology involving diverse factors, including oxidative stress, calcium overload, atrial dilatation, microRNAs, inflammation, and myofibroblast activation. 141,159,160,161,162 In a recent study of transcriptional changes associated with AF, susceptibility to the arrhythmia was associated with decreased expression of targets of several transcription factors related to inflammation, oxidation, and cellular stress responses. 163 However, it is unknown to what extent and at which time points such alterations influence the remodeling process that perpetuates AF. Moreover, rapid atrial rates activate fibroblasts to increase collagen-gene activity, and AF in isolation might promote cardiac fibrosis. 131,133,134 Cardiac fibrosis is part of the maladaptive cardiac remodeling in response to cardiac injury 164,165 and has been implicated in initiation and maintenance of AF. 166 The mechanisms that are responsible for fibrosis and its consequences comprise many phenomena occurring at various scales, including molecular, organelle, cellular, and tissue scales. 167 At the molecular scale are dynamics changes in the genome, the transcriptome, and the signaling pathways underlying the generation of profibrotic molecules 168 ; cellular changes involve interactions among the various cardiac cells, including myocytes, fibroblasts or myofibroblasts, and inflammatory cells such as macrophages and neutrophils 169 ; and tissue changes relate to the dynamics of scar, angiogenesis, electrical conduction, and contractility. 153 Fibrosis can certainly act as an electrically insulating obstacle. Profibrotic stimuli promote differentiation of fibroblasts into activated myofibroblasts, which electronically couple to myocytes in vitro 20,150,151,152 ; whether this occurs to a significant extent in AF atria in vivo remains uncertain. Fibrosis affects electrical propagation through slow, discontinuous conduction with “zigzag” propagation, 170,171 reduced regional coupling, 172 abrupt changes in fibrotic bundle size, 173 interruption of bundle continuity, and micro-anatomical reentry. 174 Another potentially important factor in AF-related atrial remodeling is fatty infiltration, which is known to increase in a number of myocardial pathophysiological conditions and is regarded as arrhythmogenic. 175,176,177 Obesity is a known AF risk factor, and the increasing incidence of AF could be related to increasing rates of obesity. 177,178 Obesity frequently coexists with other AF risk factors that improve in response to weight loss, emphasizing the importance of weight loss in AF risk factor management. 179 Epicardial fatty infiltration occurs with obesity 180 and has been associated with AF. 177 Biofactors released from fat might promote fibrosis and myocardial remodeling. Atrial Amyloidosis Over the past decade, a number of studies have called attention to a link between atrial amyloidosis and AF. 74,181,182 Amyloidosis is characterized by the presence of extracellular proteinaceous deposits showing characteristic structural and tinctorial properties. The various types of amyloidosis are distinguished based on the fibril protein deposited and the clinical presentation. Amyloidosis can affect the heart as part of a systemic process, as in immunoglobulin-derived light-chain amyloidosis. Amyloid can also be deposited in the heart as a manifestation of aging (senile amyloidosis), with amyloid observed in cardiac vessels, in the ventricular interstitium, and in the atria. The heart can also be affected by an organ-limited variant called isolated atrial amyloidosis. The incidence of isolated atrial amyloidosis exceeds 90% in the ninth decade. Studies have shown that isolated atrial amyloidosis affects atrial conduction and increases the risk of AF. Notably, there is an inverse correlation between isolated atrial amyloidosis and atrial fibrosis. Role of Intracellular Ca2+ Dysregulation Spontaneous Ca2+ release promoting triggered activity is likely to be an important mechanism of AF initiation. 183 During AF, the exceedingly high frequency of atrial excitation is expected to lead to RyR2 refractoriness 184 and downregulation of Ca2+ handling proteins, 158 acting to prevent triggered activity in the presence of persistent AF. RyR2 leakiness is therefore unlikely to contribute to persistent AF. 185 However, such considerations do not apply in PAF, in which ectopic activity likely related to Ca2+-dependent ectopy could play an important role. There is evidence that Ca2+ released from the leaky RyR2 receptors in the sarcoplasmic reticulum (SR) is exchanged by the Na+-Ca2+ exchanger (NCX), which produces an arrhythmogenic depolarizing current that induces atrial ectopic activity. 186,187 In a mouse model characterized by progressive AF, SR Ca2+ leak is enhanced in association with Ca2+/calmodulin-dependent protein kinase II (CaMKII)-dependent hyperphosphorylation of the ryanodine receptor. 188 Genetic inhibition of the Ca2+ leak reduced structural remodeling and prevented the development of persistent AF. 188 However, in isolated remodeled rabbit and human atrial myocytes, Ca2+ signaling was silenced through a variety of mechanisms. 185 The authors suggested that Ca2+ silencing might be a protective mechanism against the Ca2+ overload that occurs during chronic AF, and challenged the notion that aberrant Ca2+ release contributes to the pathophysiology of persistent AF. However, during AF, the exceedingly high frequency of atrial excitation is expected to lead to RyR2 refractoriness and downregulation of Ca2+-handling proteins, acting to prevent triggered activity. Therefore, whether RyR2 leakiness contributes to persistent AF is now being disputed. 158,184,185 A popular concept that had been promoted by some investigators over the last several years was that both initiation and maintenance of AF could be related to increased activity of protein kinase A (PKA) and/or Ca2+/CaMKII, with subsequent uncontrolled diastolic Ca2+ release from the SR. 186 The idea is that Ca2+ released from the “leaky” RyR2 receptors in the SR would overactivate the NCX to extrude Ca2+ and produce an arrhythmogenic depolarizing current, thereby explaining both the contractile dysfunction and the high recurrence rate of the arrhythmia. 186,187 In a recent study in mice with a mutation causing progressive AF, SR Ca2+ leak was reported to be enhanced in association with Ca2+/CaMKII–dependent hyperphosphorylation of the ryanodine receptor. 188 Genetic inhibition of Ca2+/CaMKII-mediated RyR2-S2814 suppressed the Ca2+ leak, reduced structural remodeling, and prevented the development of persistent AF. 188 However, recent studies in large animals and in humans have challenged the idea that Ca2+ dysfunction underlies AF maintenance and perpetuation. In isolated rabbit atrial myocytes, remodeling in response to sustained tachycardia for up to 5 days was shown to silence Ca2+ signaling through a failure of subcellular propagated Ca2+ release. 185 The authors suggested that Ca2+ silencing might be a protective mechanism against the massive Ca2+ overload that occurs during chronic AF. In another study in human atrial myocytes, although CaMKII appeared to facilitate catecholamine-evoked arrhythmias in the atrial myocardium of patients with sinus rhythm, the same agonists failed to elicit arrhythmias in the atrial myocardium of patients with chronic AF, likely related to atrial remodeling, which included decreases in CaMKII-mediated processes. 189 The above results in patients are consistent with data derived from western blot analyses in sheep, designed to test whether remodeling was related to altered intracellular calcium dysfunction. 158 Although the Na+-Ca2+ exchange was increased in the LAA of animals with persistent AF, both total RyR2 and phosphorylated RyR2 proteins were decreased, and the ratio of phosphorylated RyR2 to total RyR2 phosphorylation was unaffected. Thus, the transition from paroxysmal to persistent AF in the sheep model of atrial tachypacing did not appear to depend on Ca2+ leak or delayed afterdepolarizations (DADs). Ion Channels and Electrical Remodeling Electrical remodeling, manifested as shortening of atrial refractoriness, develops within the first few days of AF. 13,153,154,190 A number of ion channel modifications underlying such electrical changes have been described in animal models and humans. 17,190,191,192 A recent study 158 used a clinically relevant ovine model of intermittent RA tachypacing and demonstrated that, after the first AF episode, the dominant excitation frequency (DF) increased gradually during a 2-week period in both LA and RA until it stabilized at a time that coincided with the onset of persistent AF. The DF changes were associated with down-regulation of ICaL and INa and upregulation of IK1, along with corresponding mRNA or protein changes, as described in extensive previous studies of atrial remodeling. 17 Interstitial fibrosis developed at 6–12 months and coincided with persistent AF. This study highlighted progressive forms of atrial remodeling in the increasing tendency of AF to persist over time. Consistent with these findings, another study recently demonstrated that AF persistence was associated with numerous transcriptional changes in ion channel expression. 163 Such changes included upregulation of KCNJ2 and KCNJ4 (encoding Kir2.1 and Kir2.3 subunits, respectively, which contribute to IK1) and downregulation of CACNA1C (encoding the ICaL α-subunit) and CACNAB2 (an ICaL β-subunit). 163,193 Therefore, the progressive DF increase during PAF is also consistent with the fact that AF frequency is usually higher in patients with persistent than with PAF, 98 a difference that is now clearly due to sustained AF-related electrical remodeling. Sustained AF shortens APD and the ERP, decreasing the wavelength and facilitating the acceleration and stabilization of sustained reentry. The primary determinants of APD shortening are the decrease in ICaL and increase in IK1. 158 Mechanisms of AF: Multiple Wavelet Hypothesis, Reentry, Spiral Waves, Rotational Activity, and Focal Triggers from the Pulmonary Veins and Other Sites For many years, three concepts competed to explain the mechanism of AF: multiple reentrant wavelets (Figure 3A), rapidly discharging automatic foci (Figure 3B), and a single reentrant circuit with fibrillatory conduction (Figure 3C). 194, 195,196 Considerable progress has been made in defining the mechanisms underlying initiation, perpetuation, and progression of AF (Figures 3, 4). 16,17 A key breakthrough was the recognition that in some patients, AF is triggered and/or maintained by rapidly firing foci and can be “cured” by local catheter ablation. 197 This crucial observation focused attention on the PV cardiomyocyte sleeves. Subsequent work confirmed the key role of the PVs in AF, particularly paroxysmal forms, and showed that the PVs have features that make them favored zones to harbor both focal automatic and microreentrant activity. 157 The multiple wavelet concept was initially proposed by Garrey (Figure 3A), was later refined by Moe, and for at least 50 years became the dominant mechanistic framework for AF. Engelmann had earlier suggested that AF was maintained by rapidly discharging atrial ectopic foci, 198,199,200 a notion that was subsequently rejected only to periodically resurface. 201 Finally, Thomas Lewis suggested that a single rapidly rotating primary reentrant circuit (a “mother wave”) was the most likely mechanism underlying AF. 202 For AF due to a single ectopic focus or a rapidly rotating single circuit, fibrillatory conduction is required to account for the irregular activation typical of AF. 203 All three of these classical mechanisms were proposed in the early 20th century and continue to underlie much of the contemporary thinking about AF mechanisms. 195 As mentioned above, the observations of early investigators who recognized the importance of the PVs in AF were critical. Their initial observations pointed to a critical role for very rapidly discharging PV foci in maintaining AF. Subsequent experimental studies indicated that the PVs could indeed represent sites of very rapid automatic activity, which is enhanced by the rapid activation caused by AF. 204 Subsequent detailed studies of PV cardiomyocyte ion-current function 84 and structure 91 indicated that the PVs also have properties favoring local microreentry, which likely contribute to their participation in AF. Recent studies have implicated abnormal Ca2+ handling and DAD related to spontaneous ectopic activity of patients with paroxysmal or long-standing persistent AF. 186,205 However, more recent studies strongly suggest that during long-term sustained AF, one should not expect an increase in the spontaneous release of Ca2+ from the SR, nor that DADs or triggered activity is involved in AF maintenance or in the progression to stable forms of the arrhythmia. 158,206,207 Subsequent to recognition of the importance of the PVs, a variety of sites other than the PVs have been shown to potentially harbor AF-maintaining sources, 208 but the critical importance of the PVs has withstood the test of time. Allessie et al induced and mapped electrically induced tachycardia in isolated rabbit atria and documented the circular movement reentry in that model. 209 Using a limited number of electrodes, the authors detected an activation sequence that suggested centripetal direction of wavelet propagation. The authors proposed that these centripetal wavelets activated tissue at the center of the circuit, resulting in double responses (double potentials) of subnormal amplitude. Because the centripetal wavelets were unable to propagate beyond the center, they prevented the impulse from shortcutting the circuit, resulting in the maintenance of reentry. This mechanism of reentry was named leading circle reentry by Allessie et al. 209 Building on ideas put forward initially by Mines and later quantified by Wiener and Rosenblueth, Allessie et al suggested that functional reentry naturally establishes itself in the shortest circuit that can maintain reentry, defined by the distance a cardiac impulse travels during the RP. 210,211,212 This distance determines the length of the shortest reentrant cardiac excitation wave (wavelength, WL) and is equal to the product of conduction velocity (CV) and RP (e.g., WL = CV × RP). If AF is maintained by multiple simultaneous reentrant waves, the likelihood of spontaneous termination is greatest when the atria are only large enough to maintain one reentrant wave; if the wavelength is shortened so that multiple waves can be maintained simultaneously, the chances of spontaneous termination will be greatly reduced and AF is likely to be sustained. Evidence to support this notion was obtained in a dog model by varying autonomic tone and administering antiarrhythmic drugs (AADs). 211 However, some clinical observations were incompatible with the leading circle mechanism, notably the effectiveness of Na+ channel blockers in AF. According to the leading circle notion, Na+ channel blockers should decrease the wavelength by reducing CV and thereby promote, rather than terminate, AF. Furthermore, for many years, multiple numerical studies and high-density mapping studies in cardiac tissues have failed to confirm the idea of the leading circle or the presence of centripetal wavelets in the maintenance of reentrant excitation. Computer simulations and experiments in multiple mammalian species suggest that functional reentry is better explained by rotors or spiral waves (Figure 3D). This idea was first conceptualized by Russian scientists in the 1960s, and later popularized by Arthur Winfree to explain the reentry in all excitable media. 213,214,215 The rotor is the organizing center of the reentrant excitation 215 ; it spins at exceedingly high frequencies, radiating spiral wavefronts with outwardly decreasing curvature, forming an Archimedean spiral, and resulting in wave fragmentation in its periphery. 216,217 Because CV decreases as the wavefront curvature becomes steeper toward the center tip, it follows that at that site (sometimes called the phase singularity [PS]) the curvature reaches a critical value, the velocity becomes zero, and the PS follows a circular trajectory. 215,218 At each point the direction of propagation is perpendicular to the wavefront and the velocity increases toward the periphery. The PS is a unique point where the wavefront and the wavetail converge and velocity is zero, preventing the impulse from extending toward the center of the rotation. Instead, the PS becomes the rotor, circling around a small center of unexcited but excitable tissue. 218 The concept of rotor can also be applicable to anatomical reentry in the atria; a pectinate muscle or the orifice of a PV can stabilize a reentrant rotor. 156,219 Unlike leading-circle reentry, spiral-wave reentry is not determined by the wavelength, but rather by the source-sink relationship between the activation wavefront and the tissue that must be excited in front of it to maintain activity. The rotor concept has been applied to AF, and subsequent studies have confirmed its ability to account for the AF-suppressing actions of Na+ channel blockers. 119 Recent advances in electrophysiological recording and analysis have led to important advances in appreciating AF-maintaining mechanisms in patients. Interestingly, they have also led to new controversies. The application of advanced computing technology to the definition of detailed intracardiac electrical activity based on highly sophisticated body surface mapping (BSM), a technique called electrocardiographic imaging (ECGI), has led to the noninvasive analysis of underlying mechanisms in patients with AF. 220,221 Both focal and reentrant rotor sources were visualized and tended to become more numerous as AF was maintained for longer periods. 221 Detailed analysis of patients undergoing AF ablation indicates that rotors are localized to specific atrial regions and tend to be short-lasting, with rotor cores tending to occur at the interface between fibrotic tissue and more normal atria. 222 Investigators have also applied intra-atrial basket catheters and complex mathematical analysis to define AF mechanisms and target them in the electrophysiology laboratory with a technique called focal impulse and rotor modulation (FIRM). 77 FIRM procedures have identified rotational activity in patients with AF. A number of studies have shown the superiority of FIRM-based ablation over conventional ablation strategies. 223 However, the success of targeted rotational activity ablation, as well as the meaning of rotors detected by FIRM technology, have been disputed in recent clinical studies. A prospective randomized clinical trial is now underway. It is notable that conventional mapping techniques using isochronal mapping have not been able to identify continuous rotational activation. 224,225 It is also notable that detailed human atrial mapping studies have not observed discrete rotors, but rather suggest that AF is maintained by dissociation between epicardial and endocardial layers, with mutual interaction producing multiplying activity that maintains the arrhythmia (Figure 3E). 226,227,228,229 Investigators have recorded more than 500 epicardial electrograms from both atria during cardiac surgery in patients with persistent AF and were unable to identify reentrant activity. 229 They interpreted their results as suggesting predominance of focal activity and breakthroughs. Potential unifying findings were recently presented by investigators, who performed high-resolution endocardial and epicardial optical mapping in explanted diseased human hearts. 227 They noted that AF was driven by stable transmural reentrant sources anchored to anatomical complexities and fibrotic regions. One limitation of their studies was a need for an action potential abbreviating drug (pinacidil) to observe AF, limiting the applicability of their findings to spontaneous AF. In summary, although the presently available data leave a number of questions open, they do indicate that both ectopic activity and reentry play important roles in AF. The specific mechanisms and determinants remain to be elucidated, along with their implications for therapy. Mechanisms of Atrial Tachycardia and Atrial Flutter Atrial arrhythmias can be broadly classified as focal, small circuit, or macroreentry (Figure 5A–5F). Focal ATs can originate from anywhere within the atria or venous structures but do have a classical anatomic distribution (Figures 4, 5C). In the absence of a prior LA catheter or surgical ablation procedure, approximately two-thirds of focal tachycardias have an RA origin and one-third occur from the LA. In the RA, the most common anatomic locations are the crista terminalis, tricuspid annulus, CS ostium, and perinodal regions. In the LA, the pulmonary venous ostia and mitral annulus are most common. Focal tachycardias also can arise from the LA and RA appendages, but these sites of origin are rare. Macroreentry is a broad term that encompasses what have been considered to be typical and atypical atrial flutters (AFLs). The hallmark of macroreentry is that two sites ≥2 cm apart demonstrate entrainment with a postpacing interval–tachycardia cycle length of ≤20 ms (i.e., within the circuit). The most common forms of atrial macroreentry are variants of classical common and reverse common cavotricuspid isthmus-dependent flutter (Figure 5A, 5B). These include both counterclockwise (common) and clockwise (reverse common) variants, with the circuit originally described as a broad active wavefront rotating around the tricuspid annulus. However, it is now recognized that many variants exist, such as lower loop reentry and forms in which the active wavefront crosses immediately anterior or posterior to the inferior vena cava. Rarely, intraisthmus reentry can occur. Classical AFL almost invariably coexists with AF. Studies of AFL onset and termination have demonstrated that both invariably require transitional AF, indicating that flutter is largely a downstream arrhythmia. Attempts to modify the natural history of AF by ablation of AFL have thus far largely been unsuccessful. Nevertheless, cavotricuspid isthmus ablation is a simple procedure with high efficacy and low risk that can provide good arrhythmia palliation in the appropriately selected patient. However, long-term follow-up studies following flutter ablation have demonstrated increasing prevalence of AF during long-term follow-up. 230 Atypical forms of macroreentry can occur in both the LA and RA and are most common in the setting of prior atrial surgery or prior ablation for AF. They can also occur spontaneously. In the RA, these can occur in the free wall, where a surgical or spontaneous scar creates the central obstacle; or in the form of upper loop reentry in which the SVC is the central obstacle, often with some anchoring scar. Circuits have also been described around segments of the crista terminalis, which acts as a central barrier and creates regions of slow conduction. Reentrant circuits on the right septum, even in the context of surgical scars or prosthetic material, are uncommon. In the LA, macroreentry is most common in the context of prior ablation. The type of circuit varies according to the nature of prior ablation and to the underlying structural heart disease. Patients with more advanced atrial remodeling, such as those with persistent AF, will be more likely to have regions of slow conduction. Linear ablation particularly induces macroreentry due to the propensity for gaps in lines to develop. At the gap site, conduction can also be slowed due to the presence of damaged tissue. Common reentrant circuits are perimitral- or mitral isthmus-dependent or, alternately, roof-dependent circuits (Figure 5E, 5F), which occur around either the left- or right-sided PVs. Ablation of these circuits can be accomplished by creation of a linear ablation lesion in the form of a mitral or an anterior line for perimitral flutter or a roof line for roof-dependent flutters. Microreentrant AFL can be ablated with a focal lesion (Figure 5D). When flutter occurs through a gap in a preexisting line, focal ablation at that gap can often be sufficient to create complete conduction block. With the diminished use of linear ablation for persistent AF treatment, the prevalence of these circuits is expected to diminish. Whenever linear ablation is required for ablation of a macroreentrant circuit it is important to check for bidirectional conduction block. Macroreentrant circuits can also occur in the LA around large regions of scar. These can either occur spontaneously, particularly in the setting of structural heart disease and atrial enlargement, or be due to prior ablation. Simultaneous dual-loop reentry can also be observed in this situation. Left septal flutter has been described, but is an uncommon arrhythmia. When patients present with macroreentrant arrhythmias following AF ablation, it is important to also identify and ablate the trigger causing onset. Common sources of triggers include the PVs, reflecting PV reconnection, or non-PV triggers. Small circuit reentry has been described more recently, and most classically occurs in the context of a prior catheter or surgical ablation procedure due to islands of scar that form a central obstacle and regions of slow conduction (Figure 5D). The definition of a small circuit as being less than 2 cm in diameter creates a rather arbitrary distinction from macroreentry, but it does have clinical relevance. In the majority of small circuits, a single focal isthmus of slow conduction can be found in which focal ablation eliminates the circuit. Potential Benefits and Rationale for Eliminating AF with Ablation As described earlier in this document, AF is associated with many adverse outcomes, including stroke, dementia, HF, impaired QOL, increased medical costs, and mortality. Understanding the effect of catheter ablation of AF on these outcomes is important in the overall assessment of the role of ablation in the long-term management of patients with AF. There have been a number of studies that have examined long-term outcomes with AF ablation. To date, however, none have prospectively randomized patients to ablation vs medical management and followed them longitudinally for more than 1 to 2 years. There are some long-term prospective registries of patients who have undergone AF ablation, with patients matched to those treated medically. Despite rigorous propensity matching, there could still be unrecognized differences in the populations treated with ablation compared with those receiving medical management. Thus, most of the evidence we have, while suggestive of benefit from ablation, cannot be taken as definitive with respect to major health outcomes. This lack is the rationale behind the Catheter Ablation vs Anti-arrhythmic Drug Therapy for Atrial Fibrillation Trial (CABANA) (ClinicalTrials.gov identifier NCT00911508), which is a prospective, randomized trial of ablation vs medical management of AF. The trial has completed enrollment, but it will be some time before the results are known. It is widely recognized that AF ablation is effective in controlling AF and its associated symptoms. Multiple studies have demonstrated that AF ablation improves QOL in a patient with symptomatic AF, including those with HF. 231,232 Many patients with AF have HF with reduced ejection fraction (EF). Multiple studies have examined the effect of ablation on EF. 63,76,233,234,235,236 In a meta-analysis of nine studies of AF ablation in patients with HF, mean EF improved 11% (95% confidence interval [CI] 6.9–15.3, P 70 mm Hg and increase the bolus vasoconstrictor throughout infusion to maintain adequate perfusion. This is particularly important under general anesthesia. Careful titration of a vasoconstrictor allows for higher doses of isoproterenol infusion. Graded infusion of isoproterenol using up to 20–30 μg per minute for at least 10 minutes is recommended. Most members of the non-PV trigger writing group felt that lower-dose isoproterenol infusion was frequently ineffective. If no effect with isoproterenol infusion, burst pacing into AF and then cardioversion during low-dose isoproterenol infusion (2–6 μg per minute) may be considered. Use of adenosine bolus or burst atrial pacing during lower-dose isoproterenol infusion to attempt to identify repetitive triggers after the drive train is an adjunctive technique employed by a subset of the non-PV trigger writing group. Localization of non-PV AF triggers can be challenging, particularly when only the first triggering beat is being targeted, and typically involves recognition of specific intra-atrial activation patterns on multipolar catheters placed in the RA and CS, together with information from the surface ECG to help regionalize an area of interest. 458,534,535 Moving the circular mapping or ablation catheters around the LA and reinitiating AF can be useful to localize AF triggers, taking care to minimize ectopy with catheter manipulation. Placement of a multipolar catheter inside the SVC is important for identifying SVC triggers. The majority of the writing committee members perform SVC isolation if an SVC trigger is identified. To isolate the SVC, a circular mapping catheter is placed inside the SVC to identify SVC potentials. Ablation is performed proximally at the SVC/RA junction. While isolating the SVC, high-voltage pacing (at least 20 mA) is used before each RF application to check for phrenic nerve (PN) stimulation. Ablation is avoided in areas of PN capture, even if incomplete isolation is the result. SVC isolation should ideally be performed in sinus rhythm after isoproterenol infusion has worn off to avoid sinus node injury. RF application is ceased if sinus node acceleration or pauses are observed. The endpoint of SVC isolation is entry and exit block into the SVC, as is typically seen with PVI. Dissociated firing of the SVC can also be observed. In contrast to wide-area PVI and because of phrenic capture or risk of sinus node injury, a segmental approach targeting the earliest breakthrough on the circular mapping catheter is most commonly employed. While ablating AF triggers on the LA posterior wall, the RF power is typically decreased to ≤30 W. An esophageal temperature probe is frequently used. The writing group also recommends that it is reasonable to use an esophageal temperature probe during RF ablation procedures to monitor esophageal temperature and to help guide energy delivery (Class IIa, LOE C-EO, Table 3). Some committee members isolate the entire posterior wall if numerous or multifocal posterior wall triggers are identified. This can be accomplished using a “box” lesion set, including a roof line (RSPV to LSPV) and floor line (RIPV to LIPV) after PVI. If triggers are observed to be originating from the CS or the LAA, some writing committee members perform isolation of these structures, while most prefer focal ablation. LAA triggers can be identified by observing far field LAA activity on a circular mapping catheter placed in the LSPV; placing the ablation catheter into the LAA should be avoided to minimize risk of perforation or catheter-induced ectopy. Isolation of the LAA should be performed only after prior discussion with the patient and consideration of the long-term need for thromboembolic prophylaxis, with consideration given to LAA closure by one of the available methods. For other non-PV triggers, such as AT, AV nodal reentry tachycardia or AV reentrant tachycardia, focal ablation is performed. Inability to provoke the trigger with repeat isoproterenol infusion is considered as the endpoint. Observational studies have shown improved arrhythmia-free survival when non-PV triggers are targeted for ablation and effectively eliminated at the time of PVI. 537,538 In some redo ablation cases, if non-PV triggers cannot be provoked, empiric ablation of non-PV trigger sites may be attempted. The empiric targeting of frequently defined non-PV trigger sites can have more value in persistent forms of AF when triggers are not observed with provocative maneuvers. 539 The most common empiric non-PV trigger ablation is SVC isolation. Other common sites for empiric non-PV trigger ablation include the mitral annulus, limbus of the crista terminalis, mid to inferior crista terminalis, and eustachian ridge. 539 Some investigators also advocate empiric LAA and CS isolation. Despite the suggested improved outcome with elimination of non-PV triggers, the minority of operators according to a recent European survey routinely perform non-PV trigger initiation and ablation. 540 Ablation of non-PV triggers might be more important for patients with persistent forms of AF and for those patients who undergo repeat ablation procedures in whom all PVs are found to be isolated. Additional investigation is needed on the optimum method for initiating and mapping infrequent non-PV triggers. Furthermore, the value of routine non-PV trigger identification and ablation with the initial ablation procedure and at the time of repeat procedure following recurrence warrants further study. A survey of the writing group members shows that when ablating PAF with the CB system, 18% also search for non-PV triggers. Among those who use RF energy for AF ablation in patients with PAF, 41% routinely employ a strategy including administration of high-dose isoproterenol to screen for and then ablate non-PV triggers. When performing a repeat procedure in a patient with PAF, 57% of the writing group members search for non-PV triggers. When ablating persistent and long-standing persistent AF with RF energy, the percentage of the writing group members who use a non-PV trigger protocol are 35%, and 46% for first-time and redo AF ablation procedures, respectively. Based on this information and a review of the literature, the writing groups recommends that administration of high-dose isoproterenol to screen for and then ablate non-PV triggers may be considered during initial or repeat AF ablation procedures in patients with paroxysmal, persistent, or long-standing persistent AF (Class IIb, LOE C-LD). LAA Focal Ablation, Isolation, and Ligation or Resection A relatively new non-PV-based strategy for ablation of AF involves targeting non-PV triggers and reentrant tachycardias that arise from the LAA. 541 Over the past 5 years, new information has been published showing promising outcomes using a variety of non-PV-based ablation strategies that target the LAA. These strategies include focal ablation of non-PV triggers arising in the appendage, 541 electrical isolation of the LAA, 541,542,543,544 and most recently, ligation of the LAA, although this approach is an off-label use of LA tissue ligation. 532,533,535,536 LAA isolation has been described using a technique similar to that of PVI: with the circular mapping catheter positioned at the level of the LAA ostium, addressing the earliest LAA activation site (preferably during sinus rhythm). Care should be taken not to ablate inside the LAA (risk of perforation and PN injury). After LAA isolation, patients should be kept on long-term OAC or considered for LAA occlusion. This reflects the results of a recent study that has reported an increased stroke risk following LAA electrical isolation. 544 The recently published BELIEF trial randomized 173 patients to start AF ablation or to start standard AF ablation with empirical electrical isolation of the LAA. After an average of 1.3 procedures, the cumulative success at 24 months’ follow-up was 76% in the combined group vs 56% with standard AF ablation. 528,529 One approach to address this potential issue is to combine LAA electrical isolation with placement of a Watchman Device. 542,543 Recent animal and human studies have also reported the feasibility of this combined strategy. 542,543 Currently, a prospective randomized clinical trial is being performed to determine if LAA ligation with the LARIAT device will improve the efficacy of PVI in patients with persistent AF. The outcome of this trial will be required to provide a clear indication for this approach. A survey of the writing group members shows LAA focal ablation, isolation, or ligation as an initial ablation strategy in patients with PAF is used by 2% of the writing group members, and 4% use the above for repeat AF ablation procedures in patients with PAF. For patients with persistent and long-standing persistent AF, LAA focal ablation, isolation, or ligation was used by 9% of the writing group members as an initial ablation strategy in patients with PAF, and was used by 11% of the writing group members for repeat AF ablation procedures in patients with persistent and long-standing persistent AF. There is need for additional well-performed, prospective, multicenter randomized trials in order to determine the safety and efficacy of this approach. Complex Fractionated Atrial Electrogram Ablation More than a decade ago, CFAEs were reported to potentially represent AF substrate sites and became target sites for AF. 516,545 CFAEs are electrograms with highly fractionated potentials or with a very short cycle length ( 0.5 mV as healthy. 554 This differs from the experience of another investigator, in whose studies 0.5 to 1.5 mV presented an intermediate zone that did not denote substantial fibrosis but that also did not provide clear evidence for a normal atrial myocardium. 140,553 The fragmented electrogram appearance of voltages in the range of 0.5 and 1.5 mV frequently argue in favor of mild fibrosis. Certainly, there is no “yes or no” with respect to atrial fibrosis, but various grades can be observed. In summary, atrial scar is proposed for sites with no discrete electrograms (apart from potential far-field electrograms) and no local capture during pacing, dense fibrosis for sites with voltages ≤0.5 mV, an intermediate zone of mild fibrosis for sites with voltages >0.5 to 1.5 mV, and normal for sites with voltages >1.5 mV. However, with some exceptions, mild fibrosis is even assumed at sites with voltages between 1.5 and 2.5 mV. Furthermore, criteria need to be developed when other diagnostic catheters are used for EAVM, e.g., the circular mapping catheter or the Pentaray catheter. Overall, these initial single-center observational studies on ablation or isolation of fibrotic areas need to be confirmed and extended in multicenter randomized studies. Recently, the utility of delayed enhancement (DE) MRI has been introduced for detecting, quantifying, and localizing atrial fibrosis, including the definition of four categories of structural changes (Utah stages I–IV). 130,560,561 The tissue characterization of the LA wall on DE MRI correlated with EAVM and with histology from surgical biopsy specimens. 560,561 The association of atrial tissue fibrosis and AF catheter ablation outcomes, with more extensive fibrosis associated with lower efficacy, was confirmed in the multicenter Delayed Enhancement MRI and Atrial Fibrillation Catheter Ablation (DECAAF) study. 365 On the other hand, these MRI findings at this point in time require extensive MRI experience, including specification of image contrast and continuity, required to set boundaries for the various degrees of fibrosis. The reproducibility of this approach is still under investigation. A major limitation of this approach is that the degree of scar identified depends strongly on the above thresholds used to define scar. At the present time, no uniform standard has been developed. This limitation hinders the reader-to-reader and day-to-day reproducibility of MRI-determined measurements of atrial scar. Once established, however, the DE MRI quantification and localization of atrial fibrosis might be used effectively to guide individually tailored substrate elimination comparable to EAVM-guided substrate modification. Finally, tissue visualization before and also during and directly after RF catheter ablation is the target for introducing real-time MRI into the clinical electrophysiological laboratory. Currently, the DECAAF-2 trial has been launched to test the hypothesis that ablation of scar detected on MRI improves ablation outcomes for persistent AF compared with PVI alone. A survey of the writing group members shows that for patients undergoing an initial AF ablation for PAF, 7% of the writing group members employ an ablation strategy based in part on MRI or voltage mapping-detected scar, and 9% of the writing group members employ this strategy for repeat AF ablation procedures in patients with PAF. For an initial ablation procedure in patients with persistent and longstanding persistent AF, 15% of the writing group members employ an ablation strategy based in part on MRI or voltage mapping-detected scar. The proportion increases to 22% for repeat ablation in patients with persistent or long-standing persistent AF. Based on this information and a review of the literature, the writing group recognizes that the usefulness of mapping and ablation of areas of abnormal myocardial tissue identified with voltage mapping or MRI as an initial or repeat ablation strategy for persistent and long-standing persistent AF is not well established (Class IIb, LOE B-R, Table 3). Mapping and Ablation of Rotational Activity Several approaches have been developed to identify areas of rotational activity in the atria. The first identification and targeted ablation of rotational activity with fibrillatory activities was reported in 2005, using the noncontact mapping technique by Lin et al. 562 The next system that was developed for clinical use employed two 64-pole basket catheters to obtain simultaneous unipolar endocardial electrograms from 128 locations in both atria of patients undergoing AF ablation. 563 A computational mapping system (Rhythm-View, Topera, Inc.) was used to process the electrograms and generate activation movies of the atrial electrical activity. After considerable processing and interpolation, evidence was found for rotational activity in patients with paroxysmal, persistent, and long-standing persistent AF. 564 MAPs established the minimum repolarization interval and provided physiologically feasible sequential activation paths. Movies of activation patterns and isochronal maps from individual cycles showed circulating activity around a center of rotation that was identified as rotational activity. 564 Focal (centrifugal) activations were also identified. Both were considered drivers only if they sustained for ≥50 rotations or focal discharges. 563 This approach has recently been validated by linking FIRM simultaneously with optically mapped rotational activity in the same human hearts. 76 Although early reports documented findings showing that this approach to mapping and ablating rotational activity improved outcomes of AF ablation, 223,226,563,565,566,567 more recent studies have failed to confirm these early findings. 568 Issues associated with the FIRM-guided protocol that have contributed to uncertainty regarding its clinical value include difficulties with basket catheter placement and appropriate electrode contact, and the inability to identify atrial electrogram characteristics expected from rotational activity that differ quantitatively from surrounding tissue. At the time this document is being written, the approach of FIRM-guided ablation has not been universally adopted. Considerable debate continues concerning the efficacy of this ablation strategy. Further research is clearly needed. 223,564,566,569 At the present time, several prospective, randomized clinical trials are underway to evaluate the long-term safety and efficacy of this approach. Several other approaches have recently been developed to identify rotational activity as a potential target for ablation. One of these systems involves the use of high-density multipolar recordings with nonlinear analysis of the similarity index and phase mapping of rotational activity. This approach has resulted in improved ablation outcome for patients with persistent AF. 224,225 Another system that has been developed to noninvasively map rotational activity is the ECGI mapping system. 221,570,571,572 This system utilizes a multielectrode vest that records 224 body surface ECGs; electrical potentials, electrograms, and isochrones are then reconstructed on the heart’s surface using geometrical information from computed tomography (CT). A mathematical algorithm combines the body surface potentials recorded by the electrodes and the geometric information provided by CT and solves the electrocardiographic inverse problem in order to noninvasively obtain estimated epicardial electrograms. 221, 570 An advantage of this approach is that it is noninvasive, and thus can be used to provide detailed follow-up information on AF recurrence. Disadvantages of the system are that it is limited to providing virtual electrograms of the atrial epicardium; activity on the interatrial septum, the PV-LAA ridge, etc., is not recorded. Another limitation has to do with workflow and the fact that CT imaging is required to obtain the torso geometry. An additional limitation of this system is that it requires the assumption that the torso has uniform electrical properties when, clearly, thoracic tissue conducts electricity nonuniformly. A clinical trial used ECGI combined with phase mapping to identify the drivers of persistent AF in 103 patients undergoing AF ablation. They observed continuously changing wavefronts and a wide variety of rotational activity behaviors. 222 Reentrant drivers were unsustained and meandered substantially, but recurred repetitively within the same region. Computation of aggregated driver-density maps over a cumulative registering period allowed identification of a median of four driver domains per patient and helped to guide the ablation procedure. Of note, the longer the duration of sustained AF, the larger the number of driver regions. Ablation of driver domains alone terminated AF in 75% of patients with persistent AF and in 15% of patients with long-standing persistent AF. The onset or extinction of drivers during ablation was not assessed; thus, there is room for improving the ablation results if real-time data are used. 222 At the 12-month follow-up, 83% of the patients with PAF and 75% of the patients with persistent or long-lasting AF were free from AF. 222 At the present time, this system is not widely available, and few members of the writing group have clinical experience with this system. Other investigators have also reported the ability of body surface potential mapping to detect rotational activity and stable propagation patterns during AF. 573 Phase maps computed from the TQ intervals in 64 surface potentials showed complex patterns in which rotational activity could be identified, but they were unstable and lasted for a very short time. Noninvasive BSM methodology has recently started to gain momentum for the analysis of activation patterns during AF. 574,575 These investigators used a custom-made 67-electrode vest that covered the whole torso of the patient; intracardiac signals at several locations were simultaneously recorded. 574 They selected either segments without ventricular activity after adenosine infusion, or applied complex subtraction of QRST if such intervals were not found. After computing and performing comparisons between intracardiac and surface DF maps, the investigators demonstrated that high-frequency sources could be reflected on a small area of the body surface close to the atrium harboring the highest DF. 574 More recently, investigators have used phase mapping to filter the unipolar signals with a narrow 2-Hz band-pass around the highest DF (HDF filtering) to significantly improve the detection of stable rotational activity. 575 Prior to HDF band-pass filtering, phase maps displayed unstable reentries, likely as a result of superposition of the disorganized electrical activity coming from the rest of the atrial tissue. HDF filtering accentuated the organized activity of scroll waves, after which rotational activity was the main pattern of activation during AF (median of 2.8 rotations, present 73% of the time). Also, computer simulations showed that epicardial propagation is spatially smoothened when projected on the torso. For example, nearby epicardial rotational activity with opposing chirality might not be detected on the torso. This fact and the possibility of temporal intervals in which AF activity can be affected by ectopic foci, could explain the lack of detected rotational activity during the remaining 27% of the time. 575 Improved understanding of underlying mechanisms improves therapy. High-frequency reentrant sources are an important mechanism of AF maintenance in humans, even if other mechanisms might also be involved in AF initiation and maintenance. 17 Experimental data and ablation outcomes are making it increasingly clear that multielectrode approaches that provide simultaneous acquisition of tens or hundreds of recording sites from the fibrillating atria provide substantial improvement for the identification and eventual termination of AF sources. Although there is still substantial room for improvement, mapping technology is evolving at an accelerating pace, which gives hope that novel breakthroughs will enable panoramic assessment of the underlying mechanisms that underlie electrical turbulence in AF. Simultaneous high-resolution panoramic assessment of wave propagation from the body surface and the endocardium could help in tracking drifting or more stationary rotational activity trajectories over wide areas of the atria with better accuracy, and hopefully should advance ablation therapy. An important issue with these mapping forms is that they are critically dependent on electrogram acquisition, electrogram integration, and a variety of signal manipulations with mathematical techniques, including inverse solution, Hilbert, and phase transformations that produce an additional level of complexity in attempting to simplify mapping. Registration of the maps to anatomic structures, or CT or MRI and subsequent navigation, likewise add complexity to the process and underscore the need for additional translational and clinical studies to validate and clarify their utility. A survey of the writing group shows that none of the members routinely employ ablation of rotational activity during initial or repeat ablation procedures in patients with PAF; 7% do so during initial ablation of persistent and longstanding persistent AF, and 9% do so during repeat ablation of persistent and long-standing persistent AF. Based on this information and a review of the literature, the writing group recognizes that the usefulness of ablation of rotational activity as an initial or repeat ablation strategy for persistent and long-standing persistent AF is not well established (Class IIb, LOE B-NR, Table 3). Localization and Ablation of Left Atrial Ganglionated Plexi Recent experimental and clinical studies have shown that the intrinsic cardiac ANS, which is formed by interconnected clusters of autonomic ganglia, known as GP, plays an important role in the initiation and maintenance of AF. 103,105,114,116,124,355,576,577,578,579,580,581,582 Because the GP are consistently located within areas of highly fractionated atrial potentials (FAPs), also referred to as CFAEs, 103,105,114,116,124,355,576,577,578,579,580,581,582,583,584 it is useful to begin with a fractionation map of the LA and PVs during AF. The LA FAPs are usually located in four areas: (1) LAA ridge FAP area (between LAA and left PVs); (2) superior left FAP area; (3) inferoposterior FAP area; and (4) anterior right FAP area (Figure 4). GP can be localized using HFS to identify sites exhibiting transient AV block during AF. In one approach, 124,582 endocardial HFS (cycle length 50 ms, 12–15 V, 10 ms pulse width) is delivered through the distal pair of the electrodes on a mapping or ablation catheter to sites within FAPs in the LA. Sites exhibiting a positive HFS response (transient AV block, increase in mean R-R interval >50% during AF) identify the 5 major GP (Marshall tract GP, superior left GP, anterior right GP, inferior left GP, and inferior right GP) (Figure 4). HFS of a GP generally increases the degree of fractionation in the adjacent PV and frequently in distant PVs. For endocardial catheter ablation of the GP, RF energy is applied to each site exhibiting a positive HFS response (usually 25–35 W for 30–60 seconds, but the RF power and/or time is reduced when close to the esophagus). 105,124,582 HFS is repeated after each RF application. If the positive HFS response is still present, RF energy is reapplied until the response is eliminated (generally only one or two RF applications are required). Ablation of each of the five GP areas usually requires 2–12 (median 6) RF applications. 124,582 A positive HFS response might not identify the entire GP area. HFS-induced transient AV block is driven by activation of the inferior right ganglionated plexi (IRGP). Therefore, activating the Marshall tract GP, superior left GP, inferior left GP, or anterior right GP by HFS is followed by activation of other GP, including the inferior right GP, which innervates the AV node. The positive response to HFS (transient AV block) might not occur, due to ablation of one of the intermediate GP along the line to the IRGP. To minimize the loss of a positive HFS response, ablation of the GP should be performed in the following order: Marshall Tract GP, superior left GP, anterior right GP, inferior left GP, and finally inferior right GP. Other signs of GP activation (such as the onset of PV firing other than the PV adjacent to the stimulated GP) are occasionally observed during HFS, which does not produce an AV block response, suggesting lower sensitivity of HFS in identifying GP. Some reports targeted GP without HFS, delivering RF applications to the presumed anatomical locations of the GP. 245,576,583,584 The GP (identified by HFS) are consistently located within an area of FAPs, which is much larger than the GP area, suggesting that although GP ablation consistently produces CFAE (or FAP) ablation, CFAE ablation is not equivalent to GP ablation. In patients with either paroxysmal or persistent AF, GP ablation (before PVI) significantly reduced the inducibility of sustained AF. If AF remains inducible after GP ablation, GP ablation often eliminates the majority of CFAEs, despite ablating a much smaller area than the overall CFAE area. 124,582 One clinical study randomized a total of 242 patients with PAF to conventional PVI, PVI plus GP ablation, and GP ablation alone. 122 Freedom from ATAs (followed for at least 2 years) was achieved in a similar number of patients in the conventional PVI and GP ablation alone groups (56% and 48%, respectively), and in a significantly greater number of patients in the PVI plus GP ablation group (74%; P = .004). In another randomized study including 264 patients with persistent or long-standing persistent AF, GP ablation as an adjunct to PVI resulted in higher rates of sinus rhythm maintenance at 3 years (49%) compared with PVI plus LA linear lesions (34%). 585,586 In addition, LA tachycardias were less common with PVI plus GP ablation than with PVI plus linear lesions. GP ablation alone was also tested in patients with drug-refractory long-standing persistent AF, resulting in a lower success rate (38% sinus rhythm maintenance at 2 years). 583,584 A recent, prospective, randomized, surgical AF ablation study reported no improvement of outcomes by ablation of the autonomic ganglia. 123 Again, anchoring the focal ablation of a GP to other nonconducting tissue produced by PVI or anatomic structures remains critical to prevent subsequent ATs. A survey of the writing group showed that 7% of the writing group members routinely employ ablation of autonomic ganglia during initial or repeat ablation procedures in patients with PAF, and 7% do so during initial or repeat ablation of persistent and long-standing persistent AF. Based on this information and a review of the literature, the writing group recognizes that usefulness of ablation of autonomic ganglia as an initial or repeat ablation strategy for paroxysmal, persistent, and long-standing persistent AF is not well established (Class IIb, LOE B-NR, Table 3). Dominant Frequency Mapping An emergent property of the complex spatiotemporal dynamics is that during AF, the local cycle length (atrial fibrillation cycle length [AFCL]) varies depending on electrode location, with the shortest AFCLs usually localized in the LA. 587,588 The combined use of phase mapping 589 and DF mapping demonstrated that the highest DF corresponded with the location of rotational activity that was driving the arrhythmia. 590,591 A subsequent study in patients with paroxysmal or persistent AF showed that ablation of PVs harboring high DF sites resulted in an increase in the AFCL (≥5 ms) within the CS in 89% of cases. 98 Arrhythmia termination occurred during ablation in 15 of 17 patients (88%) with PAF, but in none with permanent AF. In 87% of patients with PAF, ablation at a high DF site terminated the arrhythmia. Subsequent studies supported the notion that the high DF (DFmax) sites play a role in the maintenance of AF in a significant number of patients. 592,593 Based on these mechanistic studies, a small trial of 50 patients with paroxysmal and persistent AF was performed, combining PVI with ablation of DFmax sites. At a mean of 9.3 ± 5.4 months, freedom from AF after one or more ablation procedures was achieved in 88% and 56% of paroxysmal and persistent AF patients, respectively. 593 A more recent prospective randomized clinical trial of 232 patients with paroxysmal and persistent AF reported no improvement in ablation outcomes with a DF-based approach compared with PVI alone. 594 None of the writing group members incorporate DF mapping as a routine AF ablation strategy in initial or repeat ablation of PAF. One writing group member (2%) incorporates a DF-based approach during initial and repeat ablation of persistent and long-standing persistent AF. Based on this information and a review of the literature, the writing group recognizes that a DF-based ablation strategy is of unknown usefulness for AF ablation (Class IIb, LOE C-LD, Table 3). Renal Denervation Arterial hypertension (AH) is the most frequent comorbidity in patients with AF, and this condition is also an important risk factor for the triggering and maintenance of AF. The potential antiarrhythmic role of renal denervation was demonstrated in animal studies suggesting a beneficial effect on AF inducibility, maintenance, and progression. 307,595,596,597 The positive impact of renal denervation on AF recurrence was demonstrated in a first-in human study, including 27 patients with paroxysmal or persistent AF and refractory hypertension. At 12-month follow up, the group of patients who underwent PVI plus renal denervation had a significantly higher success rate in terms of freedom from AF compared with PVI alone (69% vs 29%, respectively). Also, the reduction in BP was much more significant in the PVI-plus-renal-denervation group. 331 Recently, data were reported from a combined analysis of two randomized studies with a large and diverse group of 80 patients with AF and hypertension. For the entire cohort, renal artery denervation significantly reduced the rate of AF recurrences; however, this result was more pronounced in patients with persistent AF and refractory hypertension. 331 A case report using renal denervation instead of PVI in a patient with drug-refractory persistent AF was recently published, with no AF recurrence at 6-month follow-up. Moreover, the renal denervation resulted in a reduction of LA size. 598 The mechanism by which renal denervation, when combined with PVI, can impact outcomes of AF ablation has not been well defined. One potential mechanism is through improved control of hypertension. An alternate mechanism is through a decrease of central sympathetic activity by renal denervation. 599 The current body of evidence supporting a role of renal denervation in improving outcomes of AF ablation is extremely limited. This is an area in need of further investigation. At the present time, we do not advise renal denervation as a technique to improve outcomes of AF ablation outside of a clinical trial. This sentiment reflects not only the limited body of literature supporting this approach, but also the recent large prospective randomized SIMPLICITY HTN-3 trial that showed that renal artery denervation was safe, but was not effective in lowering hypertension. 600 Epicardial Ablation of AF More data concerning thoracoscopic epicardial ablation and combined epicardial-endocardial ablation procedures have been published since the last AF ablation consensus statement. In addition to a potentially more durable lesion set, other advantages of an epicardial approach include access to epicardial structures such as the ligament of Marshall and GP, management of the LAA, and avoidance of damaging collateral structures, such as the PN and esophagus. To date, three randomized prospective trials have compared a video-assisted thoracoscopic surgical (VATS) approach to percutaneous endocardial catheter ablation for the treatment of patients with paroxysmal and non-PAF, most of whom had failed an initial catheter ablation. 585,586,601,602 A meta-analysis of these and other observational studies demonstrated a significant improvement of arrhythmia-free survival for the VATS procedure (78.4 vs 53%; RR 1.54; 95% CI 1.50–2.14; I 2 = 0%; P 50% of the tachycardia cycle-length. 628 The main strength of activation mapping is that it is unlikely that the tachycardia will terminate. The disadvantage is that these activation maps can be extremely difficult to interpret and might not translate to identifying successful ablation sites. When performing ablation of atypical AFL with a conventional 3D mapping system, especially when a stable reentrant circuit is present that allows entrainment, most operators find that entrainment mapping from multiple sites is a better and more accurate approach to localize the reentrant circuit and target ablation lesions. It is for this reason that entrainment mapping is the gold standard for mapping reentrant tachycardias and is the preferred mapping strategy employed by most writing group members at the present time. For atypical flutter, because fusion of the F wave can be difficult to interpret, the primary goal is to identify regions with a postpacing interval within 20 ms of the tachycardia cycle length. Care should be taken to pace at or near threshold, given high-output pacing can capture adjacent tissue that leads to an erroneous postpacing interval. High-output pacing can also lead to electrode polarization that obscures the return electrogram. Once the reentry circuit is delineated, an ablation strategy can be designed to connect anatomic obstacles and interrupt the tachycardia. Despite this current preference, new high-density automated mapping systems have been developed, as noted above, which allow development of successful ablation strategies based on high-density activation mapping alone, without the risk of entrainment pacing resulting in termination of the flutter under study or its degeneration into a different flutter or fibrillation. Prospective randomized clinical trials will need to be performed to determine the true clinical value of these new automated high-density mapping systems. 627,632 For PV tachycardias, 2 gaps in the PVI line are typically present and reisolation of the PVs suffices to eliminate the tachycardia. 447 For macroreentrant tachycardias, ablation that connects anatomic obstacles is required. The classic post-PVI macroreentrant tachycardia is mitral annular flutter; ablation between the mitral annulus and left lower PV (mitral isthmus) is typically performed (Figure 5), although an anterior line between the mitral annulus and the LSPV, the RSPV, or the roof line can also be performed. For mitral isthmus ablation, epicardial ablation within the CS is required approximately 80% of the time. The endpoint of linear ablation should be proof of bidirectional block using pacing maneuvers rather than simply tachycardia termination. Interruption of the clinical tachycardia should be performed first, because burst pacing might induce multiple tachycardias of unclear significance. After termination of the clinical tachycardia, reisolation of any reconnected PVs should always be performed. Anesthesia During AF Ablation The type of anesthesia used for AF ablation depends in part on the availability of anesthesia support for ablation procedures. Given the need to minimize patient movement to improve catheter and mapping system stability, deep sedation or general anesthesia is generally preferred. One prospective randomized clinical trial randomized patients with general anesthesia or conscious sedation. This study reported that use of general anesthesia increased the single procedure success rate, lowered the prevalence of PV reconnection among those who needed a redo procedure, and shortened fluoroscopy time and procedure time. 633 Another nonrandomized clinical trial reported improved efficacy of AF ablation with use of jet ventilation. 634 A survey of the writing group members performing AF ablations found that 73% use general anesthesia, 13% use deep sedation with an anesthesiologist, and 14% use moderate conscious sedation with an electrophysiology nurse. Jet ventilation was used by only 8%. The major reason cited for not using general anesthesia was lack of anesthesiologist availability. Some proponents of not employing general anesthesia believe that the risk of an atrial esophageal fistula (AEF) could be higher in patients in whom general anesthesia is employed. 635,636,637,638,639 Recurrent AF with or without PV Reconnection Some degree of PV reconnection is observed in more than 80% of patients who are returned to the electrophysiology laboratory for a clinically indicated electrophysiology procedure. PV reconnection is also observed in patients doing well post-PVI. The Gap-AF trial reported PV reconnection at 3 months in 70% of patients randomized to complete PVI and in 89% of patients in whom a PV “gap” was left intentionally. AF recurred during the first 3 months postablation in 62% of the patients with complete PVI vs 79% of the patients in whom a gap was left intentionally. 456 When reconnection of the PVs is observed, it is recommended that the PVs be reisolated. This can be accomplished by a limited approach, which involves only targeting those PVs that demonstrate reconnection, and only targeting the segment of the PV circumference in which the PV reconnection is detected. Among the writing group members, 73% employ this strategy. An alternate approach is to be more liberal with ablation, with creation of a new circumferential lesion set around each of the PVs, which demonstrates reconnection. This approach is employed by 20% of the writing group members. An even more liberal approach is to repeat the entire WACA lesion set that was delivered the first time; this approach is employed by the remaining 7% of the writing group members. In the small proportion of patients in whom no PV reconnection is observed, there is agreement that a number of non-PV-based strategies should be considered, including searching for non-PV triggers, delivery of one or more linear lesions, isolation of the CS, isolation of the LAA, ablation of autonomic ganglia, CFAE ablation, and rotational activity ablation. A recent report suggested that the best outcomes following ablation of non-PV triggers are achieved in patients with a well-defined provocable target. 640 Each of these strategies has been described in detail in the rest of this document. Endpoints for Ablation of Paroxysmal, Persistent, and Long-Standing Persistent AF PVI is the cornerstone of AF ablation. Among the writing group members, 95% employ this endpoint during all AF ablation procedures. PVI is demonstrated by entrance block alone by 35%, and both entrance and exit block by 65%. Beyond PVI, other endpoints, particularly during ablation for persistent AF, are unclear. It has been suggested that regardless of other non-PV targets ablated, the endpoint for ablation of persistent AF should be the termination of AF either to a regular ATA, or to a sinus rhythm. Although termination of AF has been shown by some to be predictive of longer-term outcome, other studies have not confirmed this finding. 399,400,401,515,621,641,642 It is unclear whether acute, intraprocedural termination is a true indication of procedural success, or simply might indicate patients with less persistent AF who are destined to do better regardless of the approach used. A substudy of the STAR AF II trial has suggested this latter point. 643 Slowing of AF cycle length as measured from the CS or the LA or RA appendage has also been used as a surrogate for acute procedural success. However, AF cycle length prolongation can be difficult to measure reliably in AF, and prolongation is often used as a harbinger of acute termination. Again, longer baseline AF cycle length can be an indication of AF that is more likely to terminate or respond to ablation rather than indicating a procedural endpoint in and of itself. 643 Thus, AF termination of cycle length prolongation might not be useful as a sole procedural endpoint. Other non-PV targets have been suggested for ablation, particularly for persistent AF. CFAEs have been put forward as an important target, although many recent randomized studies and meta-analyses have not concluded that there is any benefit. 644 Ablation of non-PV focal triggers identified via isoproterenol challenge, ablation of atrial scarred regions, or ablation of localized rotational activations (so-called rotational activity) have also been reported to have benefit over PVI alone. 140,534,538,645 It appears that regardless of which target is chosen, complete local elimination of the target should be the goal, so as not to leave behind partially ablated tissue that could serve as a site for future AT recurrence. The best method of ablating a localized rotational activation is as yet unclear. Early descriptions suggested ablating the center of activation with several lesions and then remapping to confirm that the rotation is terminated. 563 Others have suggested that central ablation should be combined with creation of a short line to an anatomical or ablated boundary that crosses and interrupts the rotational pathway. The choice at this point is unclear. Similarly, for scar-based ablation, the best methods of defining scar are not yet confirmed (late gadolinium enhancement vs voltage mapping), and even for voltage mapping, the appropriate voltage cutoffs have not yet been validated. Furthermore, it is unclear whether such scar regions should be surrounded by lesions to isolate them from the rest of the atrium; whether ablation within the scar to eliminate all residual electrograms (so-called homogenization) should be employed; or whether these regions should also be tied to anatomical boundaries by short linear ablations. It follows from earlier comments that these scar ablations should be anchored to other nonconducting anatomical structures. There will need to be much further research into the best ablative endpoint for these ancillary targets. Empiric linear ablation likely does not add much to ablation of persistent AF. 646,647 However, if linear ablation along the roof or mitral annulus is added to target roof or mitral-dependent flutters, then bidirectional block is a prerequisite endpoint. Block across a line must be assessed in sinus rhythm and with differential pacing maneuvers, and these are described in detail in the following section. Section 6: Technology and Tools In this section, we provide an update on many of the technologies and tools that are employed for AF ablation procedures. It is important to recognize that this is not a comprehensive listing and that new technologies, tools, and approaches are being developed. It is also important to recognize that RF energy is the dominant energy source available for ablation of typical and atypical AFL. Although cryoablation is a commonly employed tool for AF ablation, it is not well suited for ablation of typical or atypical AFL. Other energy sources and tools are available in some parts of the world and/or are in various stages of development and/or clinical investigation. Shown in Figure 9 are schematic drawings of AF ablation using point-by-point RF energy (Figure 9A) and AF ablation using the CB system (Figure 9B). Radiofrequency Energy Biophysics and Irrigation The presumed basis of successful AF ablation is production of myocardial lesions that block the propagation of rapidly firing PV triggers or modification of the arrhythmogenic substrate responsible for reentry. Successful ablation depends on achieving lesions that are reliably transmural. 648,649 The conventional approach employed by cardiac electrophysiologists to reach the goal of AF ablation is RF energy delivery by way of a transvenous electrode catheter. RF energy achieves myocardial ablation by causing resistive heating of the tissue with subsequent heat conduction to deeper tissue layers. Most RF energy is delivered in a unipolar fashion between the tip of the ablation catheter and a large surface-area dispersive electrode applied to the patient’s thorax or thigh. The position of the dispersive electrode does not greatly affect lesion size or geometry. If a high-power system is used, two dispersive electrodes should be employed to avoid skin burns. With bipolar RF delivery, there is no dispersive electrode, and both electrodes are active. One commercial system delivers RF energy simultaneously through multiple electrodes in a unipolar, blended, or bipolar fashion, using either continuous unipolar delivery with an offset of the phase of the RF wave between electrodes (phased RF delivery), or field sequential unipolar and bipolar delivery between contiguous electrodes in a pre-specified ratio. 650 Although bipolar ablation can be effective in heating tissue between contiguous electrodes, the lesions are not as deep as those using unipolar ablation. Factors that will determine the size and depth of RF energy ablative lesions are power, impedance, temperature, duration, and CF. 651,652,653 High-power delivery and good electrode–tissue contact promote the formation of larger lesions and improve procedure efficacy. However, if the temperature of the electrode–tissue interface exceeds 100°C, then blood will boil and the blood proteins will form char and coagulum. As coagulum adheres to the electrode, less surface area is available for electrical conduction and the current density rises, resulting in more tissue and blood heating in a positive feedback spiral leading to a rapid rise in electrical impedance. Higher power delivery can be achieved with saline-irrigated tip catheters that cool the endocardial surface and prevent char and impedance rise. Increased convective cooling can also be achieved passively by using electrode material with high thermal conductivity, such as gold. 653 The higher power delivery achieved with tip irrigation results in greater depth of resistive heating, with significant increase in lesion size. If intramural temperatures exceed 100°C, steam expansion can suddenly vent through the endocardium or epicardium (pop lesion) and potentially cause a perforation. 654 Because of more reliable creation of transmural lesions, and reduced risk of formation of endocardial thrombus and char, AF ablation with RF catheters is most commonly performed with tip irrigation. Optimal catheter–tissue contact is achieved by a combination of steerable catheter selection, guide sheath manipulation, operator skill, and monitoring catheter–tissue CF. 655 significant complications can occur during AF ablation if high RF power is administered in an uncontrolled fashion. The increased risk of AF ablation compared with ablation of other arrhythmias can be attributable to the great surface area of tissue ablated, the large cumulative energy delivery, the risk of systemic thromboembolism, and the close location of structures susceptible to collateral injury, such as the PN, PVs, and esophagus. Thrombus and char can be minimized by limiting power and/or target temperature by monitoring the production of steam microbubbles at the catheter tip with ICE, and by cooling the electrode–tissue interface with saline-irrigated tips. 656,657,658,659 Intramural steam pops can be reduced by limiting both power and the electrode–tissue contact pressure. Duration of energy delivery affects the tissue temperature profile. The half-time of lesion growth is approximately 5–15 seconds, depending on the power used; thus, maximum lesion size is usually achieved within 1 minute. A long ablation duration will allow the heat generated in the region of resistive heating to conduct to deeper tissue layers, with maximum lesion size being achieved when the system has reached steady state. A short duration will yield maximal heating close to the source, with a steep drop in temperature in deeper layers, and might be preferred when ablating thinner regions such as the posterior LA when heating of contiguous structures (esophagus) needs to be avoided. Immediately postablation, lesions show typical coagulation necrosis, hemorrhage, and edema. Subacute lesions examined 2–7 days later show infiltration of inflammatory cells, and early chronic lesions show replacement of myocardium with granulation tissue at 4 weeks. 660 Myocardium exposed to temperatures of 50°C or higher for more than several seconds will show irreversible coagulation necrosis and evolve into nonconducting myocardial scar. 652 The mechanism of acute injury to myocardium is attributed to thermal injury to the sarcolemmal membrane with resultant depolarization and intracellular calcium overload. 661,662 In the border zone region of lesion formation, myocytes can become inactive or dormant, but then subsequently reestablish a normal resting membrane potential and normal electrical conduction. These dormant zones can be reactivated by the hyperpolarizing effects of adenosine. 465 Conversely, the inflammatory response to the acute injury and damage to the microvasculature can lead to lesion progression. Various techniques have been proposed to minimize collateral injury. Temperature sensors at the electrode catheter tip can provide gross feedback of surface temperature, but because of passive convective cooling from circulating blood flow or active cooling in a cooled tip catheter, temperatures measured at the catheter tip significantly underestimate peak tissue temperatures. Limiting power and shortening duration of energy delivery will limit collateral injury, but at the expense of reliably creating transmural lesions. ICE has been used to monitor lesion formation. If the tissue shows evidence of increased echogenicity, or if small gas bubbles are observed, then power should be reduced or terminated. 663,664 Contact Force-Sensing Catheters and Systems Contact Force During RF catheter ablation, electrode–tissue CF is one of the primary determinants of lesion size. 636,665,666,667 No effective lesion is formed without adequate CF, and excessive CF is associated with excessive deep tissue heating and an increased risk of deep steam pop (and perforation) and injury outside the heart, such as esophageal, pulmonary, and PN injury. Ablation catheters using two different technologies have been developed recently to measure real-time catheter–tissue CF during mapping and RF ablation. One catheter uses three optical fibers to measure the microdeformation of a deformable body in the catheter tip (TactiCath, St. Jude Medical, Inc.), which correlates with tip force. 668,669,670 The second catheter uses a small spring between the ablation tip electrode and the catheter shaft, with a tiny magnetic transmitter in the tip and magnetic sensors proximal to the tip to measure microdeflection of the spring (ThermoCool SmartTouch, Biosense Webster, Inc.), corresponding to tip force. 671,672,673 Both systems have high resolution ( 80% of the time, outcomes were 4.25 times more likely to be successful. 673 The most recent study to evaluate the efficacy of CF catheters randomized 117 patients with PAF to AF ablation with the Smart-Touch Catheter. Patients were randomized to having the CF information available or not available to the operator. The availability of CF information resulted in a lower incidence of acute reconnection (22% vs 32%); however, there was no difference in long-term efficacy, fluoroscopy times, or complications. 685 The efficacy of the TactiCath CFS catheter for AF ablation has been evaluated in a number of clinical trials, one of which resulted in FDA approval of this device. The TOCCATA study enrolled 35 patients with PAF and demonstrated that CF predicted freedom from AF postablation. 676 All the patients in whom the average ablation CF was less than 10 grams (n = 5) had recurrent AF by 1-year follow-up; whereas, 80% of the patients (n = 8 of 10) were free from AF at 1 year when the average CF was greater than 20 grams. The EFFICAS I study enrolled 46 patients with PAF and correlated CF with incidence of gaps in PVI lines 3 months after the initial PVI procedure. 453 The number of ablation lesions, minimum CF, and minimum force time integral 1200 grams. Segments with FTI 5 grams by 28%, >10 grams by 62%, >15 grams by 8%, and >20 grams by 3%. A CF upper limit of ≤30 grams is employed by 48% of the writing group members, less than 40 grams by 36%, and 30%), mainly located on the left side and right middle or right top PV. 69,776 Knowledge of the presence of additional veins prevents placing ablation lesions over their ostia, which could result in PV occlusion, whereas knowledge of the bifurcation pattern is essential during CB PVI, in which wiring of various branches might be needed to ensure optimal occlusion. 779 LA imaging facilitates ablation by providing detailed anatomical description of the PVs, antrum, and the remainder of the LA, enabling selection of the most suitable ablation technique prior to the procedure. 772,780 During the procedure, integration of LA images obtained by CT or MRI reduces procedural time because it enables a more accurate reconstruction of the anatomy. 41 However, this requires accurate registration. Prior to RF ablation, imaging of LA anatomy with either MRI or CT imaging is performed routinely by 59% of the writing group members. Prior to CB, AF ablation imaging of the LA anatomy with either MRI or CT imaging is performed routinely by 56% of the writing group members. Another method of intraprocedural 3D imaging of the LA is rotational angiography. After contrast medium injection in the right heart chambers, the fluoroscopy c-arm is rapidly rotated around the patient, and images are acquired throughout the rotation to generate 3D volumetric anatomical rendering of the LA. These images can then be integrated into an EAM system or superimposed on the fluoroscopic projections of the heart. 781,782 A survey of the writing group members shows that rotational angiography is routinely performed prior to AF ablation by 0% of the writing group members. After the procedure, LA imaging is valuable in detection of postprocedural complications such as PV stenosis or AEF. 783 MRI of Atrial Fibrosis and Ablation Lesions and MRI-Guided AF Ablation AF is associated with various degrees of structural remodeling of the atrial myocardium. 134,136,139,161,784 In the ventricular myocardium, MRI is an established modality to visualize myocardial inflammation and fibrous tissue by using LGE. 134,560,561,785,786 However, high-resolution imaging of atrial fibrosis remains technically challenging, with limited reproducibility of accuracy of MRI measures of fibrosis by different centers. 787 In a recent study, MRI data of 17% of patients were excluded due to poor quality. 365 MRI may be performed before catheter ablation of AF to identify atrial fibrosis, or after ablation to visualize RF lesions. 134,784,788,789 Several studies have demonstrated that the extent of atrial fibrosis evaluated by LGE prior to ablation can predict the outcomes of catheter ablation of AF. 789 Other studies have reported contradictory results. 790 In the multicenter prospective DECAAF trial, the extent of atrial fibrosis found on preablation MRI was categorized as stage 1 ( 30%). AF recurrence 325 days after ablation was independently associated with the extent of atrial fibrosis (15% for stage 1, 33% for stage 2, 46% for stage 3, and 51% for stage 4). 365 These preliminary results suggest that the extent of fibrosis can be useful to predict arrhythmia recurrences and to guide the decision to perform catheter ablation in selected patients with AF. Studies evaluating whether LGE can visualize scar lesions induced by catheter ablation with RF cryoablation or laser ablation in atrial tissue, or identify PV reconnection sites have reported conflicting results. 784,791 Overall, despite the promise of MRI techniques to improve the outcomes of AF ablation, further investigation is needed before advocating the systematic use to assist catheter ablation of AF. The DECAAF-2 study has just been launched for this purpose. This randomized, prospective, multicenter clinical trial is designed to test the hypothesis that PVI plus consolidation of fibrotic areas with RF ablation is superior to PVI alone. 791 A survey of the writing group members shows that MRI for detection of scar is routinely performed prior to AF ablation by 8% of the writing group members. During the past decade, a number of centers have developed the technology to allow real-time MR-guided electrophysiology intervention. Advantages of this approach include the absence of ionizing radiation and the ability to monitor lesion development in real time. Although these systems are still under development and are not available with routine clinical use at this time, this is an area of considerable interest that could emerge as an important ablation monitoring and guidance strategy in the future. 792,793,794,795 Section 7: Technical Aspects of Ablation to Maximize Safety and Anticoagulation Prevention of Thromboembolism During and Following AF Ablation Patients with AF are at increased risk of thromboembolism during, immediately following, and for several days to months after their ablation. 796,797,798,799 ACE lesions have also been observed after AF ablation. 800 The prothrombotic state associated with AF ablation results in a higher, but transient, thromboembolism risk in patients with AF who were identified as low-risk before ablation. Careful attention to anticoagulation of patients before, during, and after ablation for AF is critical to avoid the occurrence of a thromboembolism event. Consensus recommendations for anticoagulation prior to, during, and following ablation are summarized in Table 4. The ablation procedure leaves patients with substantial areas of damaged LA endothelium that can become a nidus for thrombus formation. Transseptal sheath placement and insertion of electrode catheters can precipitate thrombus formation on the catheter or on or within the sheath during the procedure. 768,801,802,803,804 The atrial tissue can be stunned for weeks or months postprocedure, leading to impairment of normal contraction. 805 Anticoagulation, in turn, contributes to some of the most common complications of the procedure, including hemopericardium, pericardial tamponade, and vascular complications. 806,807,808 Therefore, attention must be paid to achieving the optimal safe level of anticoagulation throughout the process. Screening for LAA Thrombi Prior to Ablation Transesophageal Echocardiography Thromboembolic stroke after AF ablation is a devastating consequence of an invasive procedure. One of the mechanisms could be dislodgement of a pre-existing clot that could be identified by a screening TEE. The risk of a thromboembolic event at the time of an AF ablation procedure varies, depending on a number of factors, including (1) the type of AF; (2) the presence, absence, and duration of AF as the presenting rhythm on the day of ablation; and (3) the patient’s stroke risk profile, including LA size and CHA2DS2-VASc score. With careful, multiplanar inspection of the LAA and the number of LAA lobes, the TEE can also provide additional information to help guide the procedure, such as identification of a pre-existing pericardial effusion, globally impaired cardiac function, presence of an atrial septal defect (ASD) or persistent foramen ovale, or fibrosis of the interatrial septum after previous ablation. 809,810,811 In addition, LA anatomical features, such as a thickened ridge toward the left PVs, PV stenosis or occlusion, or cor triatriatum, can be identified. Because many centers perform their procedures on uninterrupted OAC, one could argue that TEE is unnecessary; however, studies evaluating the incidence of LA thrombus on TEE among patients undergoing AF ablation who have been therapeutically anticoagulated have consistently demonstrated that 1.6% to 2.1% of patients will have a thrombus or “sludge” in the LAA. 796,812,813 The probability of identifying a thrombus was related to the CHA2DS2-VASc score in some but not in every case. Other risk factors for thrombus were LA size and a history of persistent AF. Among patients with a CHA2DS2-VASc score of zero, a thrombus was identified in 5% of patients with a CHA2DS2-VASc score of ≥2. The practice of routine vs selective TEE surveillance for LAA or intracavitary thrombus prior to PVI varies widely, given evidence to guide this decision is limited in terms of important clinical outcomes. 796,809,810,811,812,813,814 A survey of the writing group members shows that 51% perform a TEE in all patients presenting for AF ablation regardless of presenting rhythm and anticoagulation status. This survey also revealed that 71% of the writing group members perform a TEE in patients presenting AF who have been therapeutically anticoagulated for 3 or more weeks prior to ablation. Among patients who present for AF ablation in sinus rhythm who have not been previously anticoagulated, 78% of the writing group members routinely perform a TEE. Among patients presenting for AF ablation who are chronically anticoagulated with warfarin, 87% of the writing group members perform AF ablation on uninterrupted warfarin. Among patients undergoing AF ablation who are chronically maintained on a NOAC, 38% of the writing group members perform AF ablation on a patient receiving uninterrupted NOAC without withholding a dose. For patients not anticoagulated prior to ablation or in whom NOAC therapy is interrupted prior to ablation, 16% of the writing group members reinitiate the NOAC at 2 hours, 12% at 3 hours, 37% at 4 hours, and 35% at 4 or more hours after initially achieving hemostasis. It is important to recognize that this is a rapidly evolving area in AF ablation. The results of the above survey were obtained prior to publication of the results of the Randomized Evaluation of Dabigatran Etexilate Compared to Warfarin in Pulmonary Vein Ablation: Assessment of an Uninterrupted Periprocedural Anticoagulation Strategy (RE-CIRCUIT) trial, which demonstrated that performance of AF ablation on patients receiving uninterrupted dabigatran results in a lower rate of major bleeds compared with the uninterrupted warfarin strategy. 815,841 Shown in Table 4 are the writing group recommendations concerning anticoagulation strategies prior to ablation. As with the anticoagulation guidelines for cardioversion of AF, if a thrombus is identified in the LAA prior to catheter ablation of AF, the AF ablation procedure should not be performed. Computer Tomographic Angiography Data are emerging to suggest that CT imaging can be valuable in detecting thrombi prior to an AF ablation procedure. Several studies have investigated whether CT imaging can be used to screen for LA thrombi, with the hope of obviating the need for a screening TEE in at-risk patients. Compared with TEE as a gold standard, several studies and one meta-analysis have reported a high diagnostic accuracy of CT to detect LAA thrombi. 780,816,817 Other studies have reported lower diagnostic accuracy and high inter-reader variability in detecting LA thrombi with CT imaging. 818,819 In a meta-analysis of studies using delayed imaging protocols, the diagnostic accuracy for detection of LAA thrombi was reported to be 99%. 817 These findings suggest that cardiac CT (with an acceptable radiation dose) could be of value in detecting LA thrombi. It is important to note that in many centers the CT is obtained days to weeks prior to ablation, rendering this imaging modality of no value because of this time delay. The writing group members believe that the data are currently insufficient to recommend widespread use of CT imaging as an alternative to TEE for preablation screening for LA thrombi. This sentiment reflects in large part a great variability in CT detector imaging equipment and protocols. Further large-scale studies will be required before CT imaging can be considered an alternative for TEE screening prior to AF ablation. A survey of the writing group members shows 49% of the members employ CT imaging on a routine basis prior to AF ablation. Among those who obtain CT imaging, 32% use the CT image to identify LAA thrombi. Intracardiac Echocardiography Data are also emerging to suggest that ICE can be valuable in detecting LAA thrombi prior to an AF ablation procedure. Imaging from the pulmonary artery is preferred. Whereas the ICE-CHIP study demonstrated that ICE imaging from the RA had reduced sensitivity in the detection of LA thrombi compared with standard TEE, other studies showed that ICE imaging from the pulmonary artery can be used safely and effectively (compared with TEE) for the evaluation of the LAA in patients undergoing ablation. 768,820,821,822,823 Of interest, ICE has been shown to have complementary value in rescreening the LA and the LAA for thrombus after a recent negative or equivocal TEE. 824 These findings suggest that ICE could be of value in detecting LA thrombi. However, the writing group members believe that the data are currently insufficient to recommend widespread use of ICE imaging as an alternative to TEE for preablation screening for LA thrombi. This sentiment reflects in large part a great variability in the skills needed to both perform and interpret the results of ICE imaging for thrombi detection. Further large-scale studies will be required before ICE imaging can be considered to be a standard and proven alternative for TEE screening prior to AF ablation. A survey of the writing group members shows that 53% of the members routinely employ ICE imaging during AF ablation. Our survey revealed that ICE was being used routinely by 87% of the writing group members in the United States and Canada compared with 13% of the writing group members from other countries. Among those who employ ICE imaging, 37% use ICE to screen for LA thrombi prior to performing the transseptal stick. Based on this information and a review of the literature, the writing group recommends that use of ICE to screen for atrial thrombi in patients who cannot undergo TEE imaging may be considered (Class IIb, LOE C-EO, Table 4). Anticoagulation Systemic Anticoagulation Prior to AF Ablation Many patients who are undergoing AF ablation have an elevated risk of stroke as assessed using the CHA2DS2-VASc score and are therefore systemically anticoagulated with warfarin or with a direct thrombin or factor Xa inhibitor. 825,826,827,828 Most operators initiate therapeutic anticoagulation for at least 3 weeks prior to ablation in patients with a CHA2DS2-VASc risk score of 2 or greater, especially if they are likely to present for the procedure in AF. Because of the slow offset and onset of warfarin, these patients were historically transitioned or “bridged” with heparin or low molecular weight heparin before and after the ablation procedure. An increased recognition of bleeding complications associated with this practice, especially at the site of vascular access, has led to the use of uninterrupted warfarin, which has been shown to have a better safety profile, provided the international normalized ratio (INR) is within the target range. 399,400,401,532,533,829, 830,831,832,833,834 Dabigatran and the factor Xa inhibitors (apixaban, rivaroxaban, edoxaban) have a more rapid onset of action, a shorter half-life, and a more predictable dose response compared with warfarin. Accumulating evidence and several meta-analyses have demonstrated similar efficacy and safety of dabigatran and the factor Xa inhibitors compared with warfarin in the setting of catheter ablation. 835,836,837,838,839, 840,841,842,843 These data provide reassurance; however, several methodological considerations warrant mention. In most of these studies, one or two doses of the NOACs were held prior to AF ablation. Nearly all of the included studies were observational in design, and are therefore subject to confounding and selection bias. The sample sizes of the individual treatment arms were small, and study heterogeneity precludes statistically robust comparisons. In addition, the study populations were predominantly male, largely characterized by normal renal function, and the mean patient age was 61 years, a decade younger than the stroke prevention trial populations. The results of the RE-CIRCUIT study were recently published, which was a head-to-head comparison of performing AF ablation on patients receiving uninterrupted dabigatran vs uninterrupted warfarin. 841 This study randomized 704 patients across 104 sites to these two anticoagulation strategies. The incidence of major bleeding events during and up to 8 weeks postablation among the 635 patients who underwent AF ablation was significantly lower with dabigatran than with warfarin (5 patients [1.6%] vs 22 patients [6.9%]); absolute risk difference [RD] 25.3%, RR reduction 77%. There were six patients with cardiac tamponade in the warfarin arm vs one in the dabigatran arm. No strokes or other thromboembolic events occurred in the dabigatran arm compared with one TIA in the warfarin arm. No patients in the dabigatran arm required the specific reversal agent idarucizumab. There has been one other smaller head-to-head comparison published of uninterrupted rivaroxaban vs uninterrupted warfarin (Venture-AF, N = 248). 842 This study reported one major bleeding event, one ischemic stroke, and one vascular death, each of which occurred in the warfarin arm of the study. A third trial of apixaban vs coumadin is also underway (NCT02227550). Based on these clinical trials, it is now apparent that a strategy of performing AF ablation on patients receiving uninterrupted anticoagulation can be performed safely and minimizes the risk of thromboembolic events. specific recommendations for pre- and intraprocedure anticoagulation are shown in Table 4. Although further studies are needed to further define the efficacy and safety of performing AF ablation on uninterrupted Factor XA inhibitors or direct thrombin inhibitors, the writing committee believes that the data and worldwide experience are now sufficient to provide a Class I recommendation for performing AF ablation with uninterrupted dabigatran (Class I, LOE A) or rivaroxaban (Class I, LOE B-R), and a 2A recommendation for the other XA inhibitors for which specific clinical studies have not been performed at this time. Further studies are needed to determine if a TEE can be omitted in patients with a high stroke risk profile who present for ablation in AF and are undergoing ablation on uninterrupted anticoagulation. Data will also be needed on outcomes and use of specific reversal agents in this setting, particularly for management of serious procedural bleeding complications. 844,845 Table 4 summarizes the recommendations for anticoagulation pre-, during, and post-AF ablation, both for warfarin and for the NOACs. Intraprocedural Anticoagulation Optimal anticoagulation using heparin with close attention to maintaining therapeutic dosing during the procedure is important. It is recommended that heparin be administered prior to or immediately following transseptal puncture during AF ablation procedures and adjusted to achieve and maintain a target activated clotting time (ACT) of 300 seconds or greater (Class I, LOE B-NR, Table 4). It has been observed that thrombi can form on the transseptal sheath and/or the electrode catheter almost immediately after crossing the septum and that early heparinization substantially decreases this risk. 768,802,803,804,846,847,848 A recent meta-analysis of more than 7000 patients supports this recommendation, showing that performing ablation of AF with a target ACT >300 seconds decreases the risk of thromboembolic complications without increasing the risk of bleeding. 849 Seventy-seven percent of the writing group members administer heparin prior to the transseptal puncture. A heparin loading dose should be administered initially, followed by a standard heparin infusion. The ACT level should be checked at 10–15 minute intervals until therapeutic anticoagulation is achieved, and then at 15–30 minute intervals for the duration of the procedure. Patients receiving a vitamin K antagonist (VKA) require less heparin and reach the target ACT faster compared with NOACs; thus, when using anticoagulation strategies with the latter, more frequent ACT monitoring and higher heparin doses should be used. 840,849 This recent report from a large-volume medication center employs an initial heparin bolus of 50 units per kg in patients who are therapeutically anticoagulated with warfarin, 75 units per kg in patients who are not anticoagulated prior to ablation, and 120 units per kg for patients who are anticoagulated on a NOAC and have held one to two doses. A survey of the writing group showed great variability in loading protocols for heparin prior to an ablation procedure. The heparin dose should be adjusted to maintain an ACT of at least 300–350 seconds throughout the procedure. One-third of the writing group members routinely employ a target ACT of >350 seconds. 820,830,846 Heparinized saline should be infused continuously through each transseptal sheath to further reduce the risk of thrombi. 802 The risk of systemic embolization of thrombus formed on a sheath can be reduced by withdrawing the sheath to the RA once a catheter is positioned in the LA. Heparin infusion can be discontinued once all catheters are removed from the LA, and the sheaths removed from the groin when the ACT is less than 200–250 seconds. Sheaths can be removed during full anticoagulation by employing a figure-of-eight suture. 850 Alternatively, the heparin effect can be reversed with protamine (Class IIa, LOE B-NR, Table 4). 851 This approach is used by 70% of the writing group members. In the event of persistent bleeding or cardiac tamponade, protamine should be administered to reverse heparin. If bleeding resolves, then reversal of the oral anticoagulant is not recommended, because this continues to offer protection from thromboembolic complications postprocedure. However, if pericardial or other bleeding persists with the above measures, fresh frozen plasma can be administered for reversal of warfarin. Dabigatran can be reversed with idarucizumab. 844 Development of a reversal agent for Factor Xa inhibitors is underway but is not yet available on a clinical basis. 845 Until these agents are available, it is recommended that prothrombin complex concentrates (PCC: Factors II, VII, IX, and X) or recombinant activated factor VII (rFVIIa) be administered. 852 The increasing availability of specific reversal agents for factor IIa and Xa inhibitors will certainly encourage the adoption of continuous anticoagulation with the newer oral anticoagulants during AF ablation. Early Postprocedural Anticoagulation There is a prothrombotic milieu following RF ablation for AF due to reduced contraction of the atria, endothelial damage from ablation lesions, and a thrombogenic state. Therefore, it is the consensus recommendation of the writing group members that patients should be anticoagulated for at least 2 months postablation, regardless of their CHA2DS2-VASc score or rhythm status (Class I, LOE C-EO, Table 4). In patients treated with warfarin who have a subtherapeutic INR the day of the procedure, there are two options. First, a direct thrombin or Factor Xa inhibitor can be administered several hours following ablation. 826,827,853,854 Second, low molecular weight heparin (enoxaparin 0.5–1.0 mg per kg twice daily) or intravenous heparin can be used as a bridge to resumption of INR 2.0–3.0. For most patients, other than those with prosthetic valves who will need to remain indefinitely on warfarin, initiation of a NOAC postablation is a preferred strategy to use instead of heparin or low molecular weight heparin due to the increased bleeding risk with these agents. It is expected that patients will have their sheaths removed immediately after ablation, either with or without the use of protamine to reverse the intravenous heparin used during the procedure. Hemostasis can be achieved by either direct pressure or the use of a figure-of-8 suture. Evidence for the safety of uninterrupted NOAC therapy has increased with the recent publication of Venture AF and RE-CIRCUIT. 841,842 Despite these new data, some centers have the patient withhold one to two doses of NOACs in the days prior to their ablation procedure. For these patients, reinitiation of the NOAC should take place as soon as the clinician is satisfied that there is no significant pericardial effusion or vascular bleeding following the ablation. Similarly, for the small subset of low-risk patients who were not being treated with anticoagulation before the procedure, a NOAC can be administered immediately following ablation. The writing group members advise that readministration of a NOAC be given 3 to 5 hours after completion of the procedure and removal of the vascular sheaths, provided there is no evidence of ongoing bleeding, or a significant pericardial effusion or cardiac tamponade is reasonable (Class IIa, LOE C-EO, Table 4). Anticoagulation Considerations Two or More Months Postablation Whether elimination of AF or reduction of AF burden by catheter ablation results in a significant reduction in stroke risk is an important, and as yet unanswered, question. Until this important question is addressed by an adequately designed clinical trial, adherence to the AF anticoagulation guidelines is recommended for patients who have undergone AF ablation procedures, regardless of the apparent success or failure of the procedure (Class I, LOE C-EO, Table 4). The writing group advises that decisions regarding continuation of systemic anticoagulation more than 2 months postablation should be based on a patient’s stroke risk profile and not on the apparent success or failure of the ablation procedure (Class I, LOE C-EO, Table 4). And finally, the writing group recommends that for patients in whom discontinuation of anticoagulation is being considered based on the patient’s values and preferences, they should consider undergoing continuous or frequent ECG monitoring to screen for AF recurrence (Class IIb, LOE C-EO, Table 4). This recommendation is based on the following: (1) recurrences of AF are common both early and late following AF ablation; (2) asymptomatic AF is common, and is more common following AF ablation than prior to AF ablation; (3) AF ablation destroys a portion of the atria and the impact of this on stroke risk is uncertain; (4) there have been no large, randomized prospective trials that have assessed the safety of discontinuing anticoagulation in this patient population; (5) studies have shown that strokes in patients with AF might not be temporaneously related to an AF event 855 ; and (6) the use of direct thrombin inhibitors or Factor Xa inhibitors, such as dabigatran, rivaroxaban, edoxaban and apixaban, is more convenient than warfarin. 825,826,827,828 The small subset of writing group members who support the discontinuation of systemic anticoagulation in patients with an increased stroke risk profile make the argument that (1) continuing anticoagulation exposes patients to the risks for hemorrhage and the unfavorable effects of anticoagulation on long-term QOL; (2) several large outcome studies have reported a lower-than-expected stroke risk in patients who undergo AF ablation compared with control populations 239 ; and (3) one center has reported a low stroke risk in patients postablation who screen for AF recurrence by pulse assessment or ECG monitoring. 238,407,409,545,856,857,858,859,860 In considering these consensus recommendations, it is worth commenting that some patients who have multiple stroke risk factors are highly motivated to discontinue systemic anticoagulation and are willing to accept a possible increased risk of stroke. It is for these patients that we recommend that some type of continuous monitoring be performed to screen for silent AF at regular intervals as long as they remain untreated with systemic anticoagulation. A survey of the writing group members shows that 77% continue anticoagulation indefinitely in patients who have undergone AF ablation and who have a CHA2DS2-VASc score of 2 or greater. It is possible that the outcomes of the CABANA and Early Treatment of Atrial Fibrillation for Stroke Prevention Trial (EAST) (NCT01288352) will help clarify this issue. In selected patients with ECG, evidence of AF control, and diligent follow-up for AF recurrences, 23% of the writing group members indicated that they would consider discontinuing anticoagulation after a conversation with the patients in which risks and benefits were discussed. This survey also shows that only 1 writing committee member (2%) routinely discontinues anticoagulation in all patients following AF ablation who are AF-free. It is important to recognize that the above discussion has focused on patients at high risk of stroke (i.e., CHA2DS2- VASc score ≥2). There is far greater flexibility as to how anticoagulation is managed in patients at a low or moderate risk of stroke because current guidelines do not mandate systemic anticoagulation. Another important consideration is that patient preference plays a large role in this decision. It is our belief that patients should be made aware of the available data and consensus recommendations, and then should be encouraged to consider the risks and benefits of continuing vs discontinuing systemic anticoagulation. Some patients who are at increased risk of stroke are highly motivated to discontinue systemic anticoagulation and are willing to accept an increased risk of stroke. For these patients, we recommend diligent pulse assessment at least twice daily and strong considerations that some type of continuous monitoring be performed to screen for silent AF at regular intervals as long as they remain free from systemic anticoagulation. A final comment worth mentioning is that the mechanisms of stroke are not limited to cardioembolism due to AF; thus, other sources of emboli should also be considered, such as paradoxical embolism and atheromas from the aortic arch. In the remainder of this section, we will briefly review some of the available data. In multiple randomized trials, AF ablation was superior to AADs in reducing AF recurrence in drug-refractory patients. 861 However, stroke prevention among these strategies has been largely similar. One investigator recently undertook a meta-analysis to evaluate whether AF ablation reduces the long-term risk of stroke compared with AAD therapy. 857 Thirteen RCTs were analyzed, with 1097 patients treated by catheter ablation and 855 patients receiving AAD therapy. Overall, seven patients (0.64%) in the catheter ablation group had ischemic stroke or TIAs vs two patients (0.23%) in the drug therapy group. No difference was shown in the rate of stroke or TIA between ablation and drug therapy. To date, however, no AF ablation trial has evaluated whether successful ablation obviates the need for long-term OAC, but there are reports from large administrative registries and observational studies addressing this issue. One study evaluated the long-term results of OAC cessation after successful catheter ablation of AF.857 OAC and AADs were discontinued irrespective of AF type or baseline CHA2DS2-VASc risk score in 327 patients with drug-refractory AF after catheter ablation. Patients with a CHA2DS2-VASc score of 2 (45.4%) and 3 (23.2%) accounted for 68.8% of this cohort. In the patients with a high risk of recurrence or prior thromboembolic complications, OAC was continued for up to 6 to 12 months postablation, and antiplatelet therapy was administered to all patients who maintained sinus rhythm upon OAC interruption. After a follow-up of 46 months, 82% remained AF-free (free from AADs). No symptomatic ischemic cerebrovascular events were detected during follow-up, despite interruption of OAC in 298 (91%) patients and AADs in 293 (89%) patients. Another study reported the patterns of anticoagulation use and cardioembolic risk after catheter ablation for AF.862 They found an increased use of NOACs after ablation from 0% in 2005 to 69.8% in 2014. OAC discontinuation was high, with only 60.5% and 31.3% of patients remaining on OAC at 3 and 12 months, respectively. The rate of discontinuation was higher in low-risk patients (82% vs 62.5% at 12 months for CHA2DS2-VASc 0–1 vs ≥2, respectively; P 1 hour, and three patients reinitiated OAC due to other reasons. No stroke, TIA, or other thromboembolic event was observed during follow-up. These are important data for those patients who decide not to receive chronic OAC, and we suggest consideration of an anticoagulation strategy based on AF burden measured by monitoring. Another single-center report described outcomes in 635 patients with one or more risk factors for stroke during a mean follow-up of 836 ± 6605 days after an AF procedure. 545 Anticoagulation was discontinued in 434 of 517 patients who remained in sinus rhythm, and aspirin and/or clopidogrel was prescribed. There were three ischemic strokes and two TIAs in the anticoagulation discontinuation group. The estimated 5-year stroke rate in this group was 3%. An observational study from five large AF ablation centers included data from 3344 patients who underwent AF ablation.238 Oral anticoagulant therapy was typically discontinued regardless of the CHA2DS2-VASc score if patients did not manifest one of the following: (1) any recurrence of ATAs; (2) severe PV stenosis; or (3) severe LA mechanical dysfunction. After discontinuation of anticoagulation, the patients were treated with aspirin. If AF recurred, anticoagulation was restarted in those with a CHA2DS2-VASc score of one or more. There were 347 patients who had a CHA2DS2-VASc score of >2. Among these 347 patients, no thromboembolic events occurred. One of the most recent studies to be published reports data from the Swedish national health registry. 863 Among 1175 individuals followed for more than a year post-AF ablation, 30% discontinued warfarin treatment during the first year. In patients with a CHA2DS2-VASc score >2, the patients discontinuing warfarin had a higher rate of ischemic stroke (1.6% per year vs 0.3% per year for those who continued warfarin). Patients with a CHA2DS2-VASc score >2 and who had had a prior ischemic stroke displayed an especially high risk of stroke if warfarin was discontinued (HR 4.6). It is important to note that in this registry, recurrence rates of AF after ablation were quite high. Sixty percent of the entire cohort and 8 of the 11 patients with stroke (72.7%) underwent cardioversion of AF or a second PVI. The study convincingly demonstrated that in patients with recurrent AF after catheter ablation, a high CHA2DS2-VASc score, and/or a history of stroke, OAC therapy should not be discontinued. Because there were so few patients without AF recurrence, the question of whether “successful” AF ablation might convey a lower risk was not adequately addressed. As stated above, there is a lack of randomized trials evaluating this important clinical challenge; however, there are some ongoing trials, such as EAST and CABANA, which will address the prognostic impact of rhythm control therapy, including AF ablation and the effect of rhythm control therapy on stroke. Other trials are needed to define the optimal anticoagulation during AF ablation procedures in an era in which novel anticoagulants are increasingly used. We are optimistic about the ongoing Optimal Anticoagulation for Higher Risk Patients Post-Catheter Ablation for Atrial Fibrillation (OCEAN) trial (NCT02168829), which will effectively determine whether successful long-term reduction or elimination of AF with catheter ablation will reduce stroke risk sufficiently to obviate the need for long-term OAC. Additionally, the ongoing Prevention of Silent Cerebral Thromboembolism by Oral Anticoagulation With Dabigatran After PVI for Atrial Fibrillation (ODIn-AF) trial (NCT02067182) will address the effect of dabigatran compared with no OAC on the incidence of silent cerebral embolic events in patients with a high risk for embolic events, but who are free from symptomatic AF after successful PV ablation. Until the outcomes of such trials are available, our current treatment recommendations to continue OAC after catheter ablation of AF in patients at high risk for stroke should continue. In patients who desire to discontinue anticoagulants because of ECG-documented AF elimination who remain at risk because of high CHA2DS2-VASc score, an individualized approach after full disclosure is warranted. It is important that patients who are considering discontinuation of anticoagulation in the setting of a stroke risk profile have a complete discussion of the potential risks of this strategy. As noted above, the writing group recommends that, for patients in whom discontinuation of anticoagulation is being considered based on the patient’s values and preferences, they should consider undergoing continuous or frequent ECG monitoring to screen for AF recurrence, although recurrence of AF is only one of many reasons for stroke events after discontinuation of anticoagulation (Class IIb, LOE C-EO, Table 4). Whether this strategy results in a significant reduction of stroke risk remains uncertain at this time. Less information is available concerning the optimal approaches to anticoagulation following surgical ablation of AF. Many variables need to be considered, including whether the patient underwent ligation of their LAA and the patient’s stroke risk profile. At the present time, there is little to no evaluable evidence for or against the merits of anticoagulation following surgical ablation when the LAA has been surgically obliterated. In the absence of current evidence, the decision to anticoagulate and the duration of treatment should be made on an individual basis weighing the risks and benefits of anticoagulation in the postsurgical patient. It is, however, not unreasonable to anticoagulate for several months following surgical ablation, provided there are no other bleeding risks. For patients in whom appendage closure or ligation was performed at the time of surgical ablation, and in whom discontinuation of anticoagulation is being considered, TEE-based assessment of whether complete appendage closure has been accomplished is recommended because incomplete closure of the LAA is not uncommon. Anesthesia or Sedation During Ablation Patients undergoing catheter ablation of AF are required to lie motionless on the procedure table for several hours, and repeated stimuli from ablation are sometimes painful. For these reasons, most patients are treated with conscious sedation or general anesthesia. The choice of approach is determined by the institutional preference and by assessment of the patient’s suitability for conscious sedation. General Anesthesia AF ablation procedures are commonly performed under general anesthesia. Not only does use of general anesthesia improve the safety of the procedure for patients at risk of airway obstruction, but it also improves patient comfort and might improve efficacy by preventing patient movement during the procedure. Given the need to minimize patient movement to improve catheter and mapping system stability, general anesthesia or deep sedation are generally preferred. One prospective randomized clinical trial randomized patients with general anesthesia or conscious sedation. This study reported that use of general anesthesia increased the single procedure success rate, lowered the prevalence of PV reconnection among those who needed a redo procedure, and shortened fluoroscopy time and procedure time. 633 General anesthesia is of particular importance for patients at risk of airway obstruction, those with a history of sleep apnea, and those at increased risk of pulmonary edema. General anesthesia may also be employed electively in healthy patients in order to improve patient tolerance of the procedure. Anesthesia or analgesia needs to be administered by well-trained and experienced individuals with monitoring of heart rate, noninvasive or arterial line BP, and oxygen saturation. Guidelines for assessing levels of anesthesia and training requirements for administration of intravenous sedation during procedures have been developed by the American Society of Anesthesiologists, which can be found on their website. A survey of the writing group members shows that in the United States and Canada, 85% routinely employ general anesthesia. Outside the United States and Canada, 45% routinely employ general anesthesia. (Please also see discussion of anesthesia on page e51). Conscious and Deep Sedation Deep sedation is a step beyond conscious sedation and just before general anesthesia. Generally, only anesthesia providers or specially trained physicians can provide deep sedation because airway and hemodynamic management might be required. The major limitation to deep sedation is the need for the patient to lie on the procedure table with minimal movement during the entire procedure. RF lesions can be associated with intense pain, resulting in patient movement. The location of sites eliciting pain with RF lesions are not predictable, although are most often located on the posterior wall. Monitoring esophageal temperature during deep sedation is possible, but more cumbersome, due to intact airway reflexes that are abolished during general anesthesia. Patient movement with right phrenic stimulation during CB procedures is also a common occurrence with deep sedation, and is largely absent with the use of general anesthesia. Jet Ventilation Catheter stability and catheter contact during LA ablation are crucial for effective lesion creation. Both catheter stability and catheter–tissue CF can be further increased by reduced respiratory thoracic excursions. Data from one institution suggest improved clinical outcome as a result of enhanced lesion quality and reduction of PV reconnection when applying high-frequency jet ventilation in general anesthesia during PVI. 634,864,865 Further data from other centers are needed, however, before final conclusions can be drawn. A survey of the writing group members reveals that in the United States and Canada, 14% routinely employ high-frequency jet ventilation. Outside the United States and Canada, 4% routinely employ high-frequency jet ventilation during AF ablation procedures. Summary The type of anesthesia used for AF ablation depends in part on the availability of anesthesia support for ablation procedures. Given the need to minimize patient movement to improve catheter and mapping system stability, deep sedation or general anesthesia is generally preferred. Approaches to Minimize Risk of an AEF A rare but potentially devastating complication of AF ablation is injury to the esophagus, with the possible outcome of AEF or esophageal perforation leading to mediastinal infection, stroke, and/or death. 866,867,1398 Another complication that is thought to be related to thermal injury to the periesophageal vagal plexus is gastroparesis. 868 More information concerning the incidence, presentation, and management of these complications is presented under Section 10. Because of the serious consequences of an AEF, it is important to attempt to prevent severe esophageal and periesophageal injury. Some operators design the ablation lesions to avoid the esophagus. The location of the esophagus can be visualized using a variety of approaches, including multidetector CT, topographic tagging of the esophageal position with an EAM system, barium paste, and ICE. 869,870,871,872,873,874,875,876 It is important to know that esophagus location can change during the procedure, and repeated imaging or visualization is needed to account for the motion of the esophagus. However, it is difficult to accomplish complete PV ablation without some ablation in close proximity to the esophagus. Strategies to prevent and treat esophageal injury follow. Reduced Power Delivery on the Posterior Wall Higher power and greater depth of tissue heating or cooling are associated with increased risk of esophageal injury. In order to minimize injury to the esophagus during RF applications on the posterior wall close to the esophagus, several approaches can be employed, including (1) reduction of RF power (e.g., ≤25 W); (2) shortening RF application time (e.g., ≤20 seconds); and/or (3) decreasing CF (e.g., ≤10 grams). The writing group recommends that RF power be reduced when creating lesions along the posterior wall near the esophagus (Class I, LOE C-LD, Table 3). Some reports employed the use of light conscious sedation to use pain to identify potential esophageal injury. However, there are conflicting data on the specificity of the pain response. It has been proposed that an alternative energy source, such as the CB for PVI, could minimize esophageal injury 877,878 ; however, AEF or periesophageal vagal plexus injury after CBA has been reported. 879,880 There are also data that other heat-based energy sources, such as high-intensity focused ultrasound or laser energy, can damage the esophagus. 501,502,700,701,705,881 Although each of these approaches is variously adopted by different ablation centers, each remains largely unproven due to the rarity of an AEF as a complication. Esophageal Temperature Monitoring A strategy to avoid esophageal injury employed by 65% of the writing group members is luminal esophageal temperature monitoring, used to identify potentially dangerous heating of the esophagus. 882,883,884,885 Unfortunately, because the esophagus is broad, the lateral position of the temperature probe or mapping electrode might not align with the ablation electrode, and the operator could receive a false impression of safety. 1398 There is general agreement among those operators who employ temperature probes that an increase in esophageal temperature should trigger interruption of RF energy delivery. Three-quarters of the writing group members terminate ablation if they observe a 1°C or 2°C rise in temperature from baseline, or a recorded temperature of 39°C–40°C. During CBA, two-thirds of the writing group members monitor esophageal temperature, and terminate cooling if the esophageal temperature reaches 20°C–25°C. A variety of esophageal temperature probes are available for clinical use. 886 A recent study has shown the superior thermodynamic profile of multisensor esophageal recording systems; however, no clinical trial has demonstrated superiority in terms of reducing AEFs. 646,647 This type of study would be impossible to perform due to the very low event rate of this complication. Among the writing group members who employ esophageal temperature monitoring, single thermocouple probes are used by two-thirds and multithermocouple probes are employed by one-third. The potential benefit of multithermo-couple probes must be weighed against their increased complexity and cost. 886,887,888,889 The writing group recommends that it is reasonable to use an esophageal temperature probe during RF ablation procedures to monitor esophageal temperature to help guide energy delivery (Class IIa, LOE C-EO, Table 3). Another strategy to protect the esophagus uses active cooling. 890,891,892,893 This technique has not been tested on a large scale, and the data describing this technique are limited. Selected operators use mechanical displacement of the esophagus. 894,895 This technique appears to be promising, but its use has been limited to a small number of patients and is therefore an unproven approach. Pharmacological Prophylaxis Esophageal ulcers are found in a 5%–40% of patients following AF ablation. It is hypothesized that AEF occurs because there is transmural necrosis of both the atrium and esophagus with subsequent ulcer erosion from gastroesophageal reflux. 896,897 To prevent ulcer erosion, proton pump inhibitors (PPIs) have been employed, and are used by 65% of the writing group members after ablation. PPIs are highly effective in gastroesophageal reflux disease by reducing the acidity of the gastric juice and healing esophagitis. 898,899,900 PPIs are effective in reducing the size of iatrogenic-induced ulcers, therefore could also be helpful for ablation-induced ulcers. 901 Other mechanisms, such as traumatic injury of the esophageal wall, could also play a potential role in fistula formation, although there is no proof of this concept. Prophylactic short-term use of PPIs after AF ablation is assumed to be effective; however, further large randomized studies are required to determine whether PPIs reduce AEFs. Because of the low event rate of AEFs, such a study will not likely be performed. At the moment, PPI therapy is justified as a singular preventive treatment. Role and Indications for Endoscopic Screening for Ulceration Following AF Ablation Because AEF can cause septicemia and air embolism leading to death, early detection of esophageal tissue injuries is essential. Data evaluating the role of gastrointestinal endoscopy for detection of esophageal tissue lesions are limited. In 185 patients who underwent gastrointestinal endoscopy after LA RF ablative therapy, ulcer-like or hemorrhagic esophageal thermal lesions (diameter: 2–16 mm) were observed in 14.6% of the patients. 902 These lesions only occurred when the intra-luminal esophageal temperature had reached more than 41°C. The odds of an esophageal lesion increased by a factor of 1.36 (95% CI 1.07–1.74; P = .012) for every 1°C rise in temperature. Gastrointestinal endoscopy in a cohort of 425 patients 1 to 3 days after AF catheter ablation, in whom intraluminal esophageal temperatures higher than 41°C were recorded, revealed esophageal tissue lesions in 11.6% of asymptomatic patients. 903 Hence, these observations suggest that asymptomatic patients could benefit from routine gastrointestinal endoscopy after RF catheter ablative therapy when the intraluminal esophageal temperature during the procedure has reached a certain target temperature, such as 41°C. However, there are no reports on the value of this type of follow-up endoscopic examination after ablative therapy. Only one study did a follow-up endoscopy at least 7 days after the first examination in patients with an esophageal lesion diameter >5 mm and found regression of all 3168 lesions. 903 A PPI was used in all the patients for 4 weeks after ablation. Role and Indications for CT Imaging for Diagnosis of Atrioesophageal Fistula After ablation, symptoms and findings suggesting the possibility of evolving AEF include chest pain, painful swallowing, fever, leukocytosis, TIA, and/or stroke typically occurring between 1 and 3 weeks postablation. If esophageal injury is suspected, CT imaging with intravenous and water-soluble oral contrast is recommended. 904,905,906 Findings on CT imaging on an AEF include mediastinal or pericardial free air, evidence of free communication between the esophagus and pericardium or atrium, and inflammatory phlegmon between the esophagus and the heart. Unfortunately, these CT findings are usually observed late in the progression of AEF. The appearance of the CT scan early in the course of this complication can be entirely normal. If esophageal injury postablation is suspected, but if the CT scan is normal, the physician must continue to have a high index of suspicion and repeat imaging if symptoms or findings do not resolve. Esophageal ultrasound can also be useful in this setting to disclose muscle and external injury, beyond a simple ulcer. Although a barium swallow can detect a fistula, its sensitivity is low. If an AEF is suspected, endoscopy with air insufflation should be avoided, given that insufflation of the esophagus with air can result in a large air embolus, producing stroke or death. An alternative strategy, which some members of the writing group employ and which appears to have lower risk is to use CO2 instead of air for insufflation in this setting. If CO2 were introduced into the LA, there would be little adverse consequence. The early recognition of an AEF can be missed due to the low awareness of this rare complication. It is important for patients to be educated as to warning signs and to contact their AF ablation center should any suggestive symptoms develop. Management of Atrial Esophageal Fistula The management of AEF following catheter ablation for AF includes preventive measures and therapeutic options. If AEF is diagnosed, available therapeutic options are as follows: surgical repair of the fistula via thoracotomy (combined LA and esophageal repair with an intercostal muscle flap inserted in between to prevent future recanalization of the fistula tract) via thoracotomy; the less invasive esophageal stenting, followed by long-term antibiotic therapy; and conservative management with aggressive chest tube drainage and treatment of sepsis. 341,417,907,908,909,910,911 Of the above three, conservative treatment of AEF is associated with a high mortality rate. 907,1398 Similarly, with esophageal stenting, earlier studies have reported fatality in the majority and survival in very few only after undergoing emergency surgical repair. 341,417,896,897,907,910,911,912,913,914,1398 Mixed results have also been shown for surgical repair of AEF complicating RFCA, some with positive outcome and others with fatal ending. 341,417,910,911 However, the only reported survival in patients thus far underwent surgical fistula repair, and failure of surgery has been mostly attributed to delay in diagnosis and intervention. 341,417,910,911 Thus, based on currently available clinical information, it is apparent that early surgical intervention is critical for survival in AEF manifesting as a complication of AF ablation. Of note, there are few reports on successful resolution of the fistula with stenting in patients with cardioesophageal (connecting to CS) and esophagopericardial fistula. 905,915,916 In cases of perforation (not thermal injury) before the fistula has formed, closure with stent or endoscopic clip can be considered. 917,918,919 Summary Although all of the approaches described above for the prevention of AEF have been variously adopted by different ablation centers, each remains largely unproven due to the rarity of an AEF as a complication. Among the writing group members, 67% employ an esophageal temperature probe (single thermocouple for two-thirds, multiple thermocouple for one-third), 36% use 3D image integration and import the esophagus location into the electroanatomical map, 91% decrease RF power when ablating on the posterior wall of the atrium, 7% use barium paste, and none (0%) mechanically displace the esophagus. Among the writing group members, 30% limit power to ≤20 W on the posterior wall, 45% limit it to 25 W, 18% to 30 W, and 7% use powers of >30 W. The writing group recommends that it is reasonable to use an esophageal temperature probe during RF ablation procedures to monitor esophageal temperature and to help guide energy delivery (Class IIa, LOE C-EO, Table 3). The writing group recommends that RF power be reduced when creating lesions along the posterior wall near the esophagus (Class I, LOE C-LD, Table 3). Despite its rarity, the devastating consequences of AEF demand that the operator maintain a high index of suspicion for this diagnosis. Presenting symptoms, including fever, dysphagia, and neurological deficits, often occur in the several weeks after the procedure. 918 Therefore, early signs of these symptoms should be reported by patients to their treating electrophysiologist to avoid the delayed diagnosis. 908 If AEF is suspected, standard transesophageal endoscopy should be avoided, because esophageal perforation can be exacerbated and air embolism promoted by required air insufflation. An alternative strategy, which some members of the writing group employ and which appears to have lower risk is to use CO2 instead of air for insufflation in this setting. If CO2 were introduced into the LA, there would be little adverse consequence. In patients diagnosed with an AEF, surgical treatment is recommended. Section 8: Follow-up Considerations Monitoring for Complications in the First Months After AF Ablation AF ablation is an invasive procedure that entails risks, most of which are present during the acute procedural period. However, complications can also occur in the weeks or months following ablation. 920,921,922 Recognizing common symptoms after AF ablation and distinguishing those that require urgent evaluation and referral to an electrophysiologist is an important part of follow-up after AF ablation. Symptoms and complications can be divided into those that occur immediately after ablation (0–3 days), early (1–4 weeks), and those that can occur late (>4 weeks) after ablation. Signs and Symptoms of Complications Within 1 Month Postablation Shown in Table 5 is a list of signs and symptoms that can occur within the first several months following ablation. These signs and symptoms are divided into those that occur within 30 days of AF ablation and those that occur more than 30 days postablation. Some complications, such as a stroke or development of an AEF, might present within the first month or following the first postablation month and therefore are listed in both sections of this table. The differential diagnosis, which should be considered, as well as the recommended evaluation, are also shown. AF ablation is often performed under general anesthesia. Some patients might feel fatigued for several days after prolonged general anesthesia. Mechanical complications from endotracheal intubation and transesophageal echocardiography, such as hoarseness and difficulties swallowing, might also occur and typically resolve with time. Tenderness at the vascular access sites is common; hematomas present after sheath removal will typically extend inferiorly (due to gravity) and might result in extensive ecchymosis after ablation. Prompt ultrasound Doppler investigation should be performed if an AV fistula or pseudoaneurysm is suspected. Worsening of back or buttock pain is also common from prolonged supine positioning during the procedure. However, more severe back pain or flank ecchymosis should prompt an evaluation for retroperitoneal hematoma with CT imaging. Significant bleeding into the leg can also result in compartment syndrome. Shortness of breath soon after ablation might have several causes. The patient should be examined after ablation for evidence of volume overload related to irrigated ablation and diuresed as necessary. Volume overload can be observed in patients with normal or reduced cardiac function, perhaps due to atrial stunning. If dyspnea persists or occurs in the absence of volume overload, a chest X-ray should be obtained to exclude an infectious process or elevation of the respective hemi-diaphragm. PN injury most commonly occurs after balloon-based ablation, but can also occur after RF ablation. 503 Lack of diaphragmatic movement during inspiration under fluoroscopy (the sniff test) is diagnostic of PN injury. Right PN injury is much more common after AF ablation and is due to ablation near the RSPV or SVC (Figure 1). Left PN injury less commonly occurs when ablating near the LAA. Although most cases of phrenic injury recover with reinnervation over a 6–12 month period after ablation, permanent diaphragmatic paralysis has been reported. Chest pain is common after ablation; the causes include pericarditis, coronary ischemia, and musculoskeletal pain. Symptoms of pericarditis (pleuritic chest pain) are the most common (>75% of patients) and typically persist for up to a week postablation. In the absence of evidence of hemodynamic compromise, an ECG is of little value. It is important to recognize that nearly all patients will demonstrate a small pericardial effusion following AF ablation as a result of edema. Nonsteroidal anti-inflammatory agents are recommended for symptom control. Colchicine can also be used to treat pericardial symptoms. Oral steroids should be avoided after catheter ablation unless pericardial symptoms persist or are recurrent. Chest pain that is associated with ECG changes or that occurs with exertion should prompt evaluation of coronary ischemia. In particular, if ablation has been performed inside the CS to target the epicardial portion of the mitral isthmus, or for isolation of a CS tachycardia, circumflex artery stenosis should be considered. 923 Any unexplained hypotension during or following ablation should be evaluated promptly. Transthoracic echocardiography or ICE (if during ablation) should be performed urgently to exclude pericardial effusion or cardiac tamponade. A complete blood count should be performed to exclude bleeding or infection. Fever might occur early after ablation. We should exclude infectious sources such as a urinary tract infection related to bladder instrumentation or pneumonia related to intubation. Low-grade fever might also be related to pericarditis. In addition, fever might be the first marker of an impending AEF formation. Chest imaging should be considered if fever persists, an AEF is suspected, and no other clear infectious source is identified. Any neurological symptoms occurring shortly after ablation should be taken seriously, with brain imaging performed to exclude an embolic event. Migraine-like signs and symptoms have been reported and are most commonly benign and are attributed to the residual ASD following transseptal puncture. As noted above, an AEF might also present with neurological symptoms. It is also important to recognize that an AEF might present as a neurological event and therefore must be considered the differential diagnosis of neurological symptoms that develop post AF ablation. Symptoms of pericarditis typically persist up to a week after ablation (Table 5). If symptoms persist for >1 week or are associated with lightheadedness or shortness of breath, further evaluation is warranted. Groin pain that persists past 7 days or is getting worse should prompt a physical exam and vascular ultrasound to exclude femoral access complications. A persistent nagging dry cough might also be observed for up to 6 weeks after ablation. This complication is more common with CB than with RF ablation and is likely related to direct bronchial or lung injury. This type of cough is generally treated with antitussives and will typically subside over 4–6 weeks. Some patients, particularly those with a history of migraines, might experience migraine headaches in the first few weeks after ablation. 924,925 These headaches might be related to the residual ASD present after transseptal puncture and will typically improve over several weeks. Hemoptysis is rare but might result from pneumonia or pulmonary infarction due to an occluded PV, typically occurring 3–6 months after ablation. Dysphagia in the first days after ablation is most likely related to irritation from transesophageal echocardiography or intubation. If dysphagia persists, then imaging (chest CT or MRI) should be performed to exclude an AEF (see late complications). The differential diagnosis of dyspnea occurring early after ablation should include volume overload, pneumonia, or PN injury as outlined above. A chest roentgenogram should be obtained. If symptoms persist with a normal chest roentgenogram, we should also consider PV stenosis (see late symptoms, below). Vagal denervation of the esophagus or stomach can occur after ablation due to ablation lesions placed in the vicinity of the esophagus, particularly if extensive ablation is performed along the LA posterior wall. 536,926 Symptoms can include nausea and early satiety. Patients should be advised to eat small, frequent meals. Symptoms will typically improve over 4–6 weeks. If symptoms are profound or persist, a gastric emptying study can be diagnostic. Pain at the site of sheath insertion can result from an pseudoaneurysm, an AV fistula, or a hematoma. Evaluation usually starts with a vascular ultrasound. Bloodwork and a CT scan might be appropriate. Signs and Symptoms of Complications More Than a Month Postablation Late symptoms of dysphagia and/or fever, particularly in the presence gastrointestinal bleeding or any neurological symptoms, should prompt an urgent evaluation for an AEF, a rare but potentially lethal complication after AF ablation (see Section 10). 341,417,866,910 If AEF is suspected, esophagogastroduodenoscopy should not be performed, because increased pressure in the esophagus can lead to the introduction of air into the LA and stroke. Imaging with CT or MR is preferred, with the presence of air in the mediastinum or LA considered diagnostic. Although barium should not be introduced into the esophagus, a small amount of water-soluble contrast can help identify the location of the fistula. The recommended treatment for AEF at any stage is surgical exploration and resection of the fistulae, typically requiring resection of the involved esophagus and repair of the posterior LA wall with a pericardial patch. There have been reports of treatment of early fistulae with covered esophageal stents; however, surgical treatment is generally preferred. A persistent cough >6 weeks after ablation, particularly if associated with atypical chest pain, recurrent pneumonia or hemoptysis, should prompt an evaluation for PV stenosis. 927,928 A chest roentgenogram might also show evidence of atelectasis or infiltrate localized to one lobe of the lung, which is typically related to focal pulmonary edema. Many patients have received repeated courses of antibiotics for lung infection before the correct diagnosis is reached. If PV stenosis is suspected, a chest contrast CT angiogram or MR angiogram should be performed to examine PV anatomy and exclude PV stenosis or occlusion. If PV stenosis or occlusion is detected, a ventilation or perfusion scan is typically performed to quantify lung perfusion. Referral to a center with expertise in PV stenting should be recommended early in the course of PV stenosis, because dilatation is more difficult and has a higher incidence of pulmonary hypertension, lung infarct, and hemoptysis once high grade stenosis has occurred (see Section 10: Complications). Hemoptysis should trigger an evaluation for PV stenosis and usually indicates the presence of complete branch or PV occlusion. Other late complications include a stroke or embolic event related to recurrent AF or deep vein thrombosis or pulmonary embolus related to femoral vein instrumentation. These complications are uncommon because anticoagulation is typically reinstated after ablation. ECG Monitoring Pre- and Postablation Arrhythmia monitoring is an important component of the initial evaluation of patients who are to undergo catheter ablation procedures for AF. Prior to undergoing a catheter ablation procedure, it is important to confirm that a patient’s symptoms result from AF and to determine whether a patient has paroxysmal or persistent AF. The choice of ablation technique, expectations with respect to the procedure’s outcome, anticoagulation strategies employed, and the need for TEE prior to the procedure might be impacted by the accurate characterization of the AF type and burden. Preprocedure arrhythmia monitoring is also useful to determine whether a patient has evidence of regular supraventricular tachycardia that degenerates into AF as a triggering mechanism or has a pattern of repetitive “focal firing,” characterized by the presence of frequent atrial premature beats (>1000 per 24 hours) with frequent rapid salvos of nonsustained AT. 458 Focal AF is characterized by localized triggers arising from the PVs. 929 Either of these triggering patterns of AF initiation identifies a patient in whom a more limited ablation, targeted at only the triggering arrhythmia focus or PV(s) might be appropriate. 406,458,930 An assessment of the adequacy of heart rate control is particularly important in patients with depressed left ventricular function who might show evidence of a reversible tachycardia-induced cardiomyopathy. 234 ECG monitoring also plays an important role in the follow-up after an ablation procedure. Early recurrences of AF are common during the first 3 months following a catheter ablation procedure. 931,932 For this reason, arrhythmia monitoring to assess the efficacy of catheter ablation is typically delayed for at least 3 months following catheter ablation unless required to evaluate arrhythmia symptoms during the early postablation period. However, recurrences particularly after the first month following an ablation procedure are predictive of later recurrence of AF, and therefore monitoring may be used to identify patients at higher risk of needing a second ablation procedure or ongoing AAD therapy. 272,329,933,934,935 The two main reasons to perform arrhythmia monitoring following catheter ablation are clinical care and as part of a clinical research trial. From a purely clinical perspective, arrhythmia monitoring is useful to determine whether a patient’s complaints of palpitations result from recurrent AF or other ATA. Complaints of palpitations often result from atrial or ventricular premature beats and are not an accurate predictor of recurrent AF. 57,936 Arrhythmia monitoring can also be of value in asymptomatic patients and can influence decision making regarding anticoagulant therapy after ablation. Multiple studies have demonstrated that asymptomatic AF commonly occurs in patients following catheter ablation. 56,57,63,413,442,936,937,938 Detection of these asymptomatic episodes of AF impact the characterization of the procedure as “successful.” Arrhythmia monitoring is an essential component of clinical trials aimed at assessing the outcomes of catheter ablation procedures and should be incorporated into all clinical trials designed to assess the efficacy of AF catheter ablation tools and techniques. The suggested monitoring strategies and minimum standards to be used as part of clinical trials are discussed in Section 13: Clinical Trial Design. These strategies and standards can be useful in tracking the outcome of clinical care when assessing an institution’s performance standards related to success and complications of AF ablation procedures. However, it is recognized that clinical endpoints and clinical trial secondary endpoints for defining success can include the elimination of symptomatic AF and control of AF with previously ineffective AADs after the AF ablation procedure. Available Methods for Arrhythmia Monitoring Use of ECG monitoring tools is essential to assess AF ablation success, and the monitored results can have important implications in terms of clinical care and research outcomes. Arrhythmia monitoring can be performed with the use of noncontinuous or continuous ECG monitoring tools (Table 6). The choice of either method depends on individual needs and the consequences of arrhythmia detection. More intensive monitoring is associated with a greater likelihood of detecting both symptomatic and asymptomatic AF. 57,414, 937,938,939,940,941,942,943,944 The proportion of asymptomatic compared with symptomatic events might be higher after AF ablation; two studies reported that the proportion of AF events that were asymptomatic was 11%–35% prior to and 53%–65% after ablation. 63,945,946 Another study reported that for patients in sinus rhythm, 53.8% of AF episodes were asymptomatic, with an increase in asymptomatic episodes changing from the acute to the chronic period after ablation, demonstrating that AF success cannot be based on the absence of symptoms alone. 936 The identification of AF and the assessment of AF burden with intermittent monitoring have been shown to depend on a patient’s actual AF burden and improve with an increasing frequency or duration of intermittent monitoring. 943,947,948,949 Conversely, the more complex and longer the method of monitoring used, the lower the patient compliance. Traditional AF detection tools for intermittent monitoring after AF ablation include scheduled or symptom-initiated standard ECGs, Holter monitors, patient-activated and automatically activated full disclosure external loop recorders, and transtelephonic recordings. More recently, implanted loop recorders and external recordings with wireless connection via smartphone applications have been used for longer-term monitoring to detect AF after ablation. The intermittent, scheduled use of continuous short-term ECG monitors after AF ablation has utilized traditional Holter monitors and more recently patch ECG monitors. Holter monitors use single- or multi-lead external recorders connected via wires to small recording devices. Typical Holter monitors record 2 or 3 channels for 24–48 hours, but some can record continuous 12-lead ECGs or for periods of 7–30 days. Patients can record symptoms on a diary and/or by activating an event button. Because Holter monitors are analyzed by trained technicians and are read by experienced physicians, these approaches might represent the standard monitoring method against which other methods should be compared. Newer wearable patch ECG monitors record from closely spaced electrodes, removing the need for wires and typically generating up to 2 channel recordings. These are water resistant, wearable for up to 30 days, and have enjoyed superior patient acceptance over conventional wired monitor systems. Symptoms can be recorded by an event button. Future devices are being developed with multiple sensors that can record body temperature, activity, respiratory rate, and galvanic skin responses. Patient- or event-activated external loop recorders can be used for longer or intermediate duration monitoring, typically over weeks to months. 254 These memory loop recorders can be programmed to record ECGs for seconds to minutes before and after the detection of an arrhythmia or a patient-triggered event and thus can detect and correlate rhythms with even brief symptoms. External loop recorders should be worn continuously to capture such events and typically are connected via wires to skin electrodes. Nonloop external event recorders can be used for intermittent transtelephonic recordings that can be initiated by patients with symptoms or on a schedule. These recorders are applied to the chest or held by hand. Older conventional transtelephonic monitors required the recording of rhythm strips while connected in real time over the phone, but more recent monitors allow the storage of rhythm strips with transmission at a later time. Event recording occurs after an event is detected by the patient; the diagnostic yield is dependent on the recognition of symptoms, the duration of symptomatic episodes, or on scheduled or more frequent use to detect asymptomatic arrhythmias. More recently, smartphone-based ECG monitors have been developed that can be helpful for long-term intermittent surveillance. 950,951 Recordings from electrodes embedded in a smartphone case or a card are connected via low-energy Bluetooth technology to smartphone applications. These monitors are nonlooping; patients can record during symptoms that persist long enough to activate the application. Recordings are stored and can be transmitted via wireless or cellular networks. In a study conducted after AF ablation, a smartphone-based single-lead system was compared to trans-telephonic monitor ECGs with 100% sensitivity and 97% specificity in detecting AF or flutter. 951 Multi-lead and reconstructed 12-lead recording devices are being developed, but have not been studied in the setting of AF ablation. Continuous ECG monitoring technology using such applications are also in development. Mobile cardiac outpatient telemetry devices provide real-time monitoring and wireless transmission to trained personnel at a central monitoring center with activation of alarms to caregivers for specified significant arrhythmias. These monitors are typically worn continuously for a period of 2–4 weeks and can record 1–3 leads connected to a small device via conventional wires or embedded in a patch. The advantage of these systems is their ability to capture and identify potentially severe or significant arrhythmias in an immediate or timely fashion. Continuous ECG monitoring for longer periods (1–3 years) can be facilitated with the use of implantable devices. Long-term subcutaneous implantable loop monitors can facilitate continuous AF monitoring based on R-R interval analysis over a time period of up to 3 years. 952,953 These types of continuous ECG monitoring devices have been used in several studies to evaluate the results of surgical or catheter AF ablation. 127,607,938,953,954,955,956,957,958,959,960,961 Although implantable subcutaneous monitors hold promise for the determination of AF burden in the long term, AF detection algorithms are primarily based on R-R interval regularity, and important limitations include reduced specificity due to undersensing of beats, oversensing of myopotentials, and irregular atrial and ventricular premature beats, as well as limited memory resulting in electrograms not being retrievable to verify the correct rhythm diagnosis. 941,944,962 Nevertheless, implantable continuous monitors can ameliorate patient compliance issues and provide an assessment of long-term AF burden and late recurrences, including asymptomatic episodes that might have implications for continuation of anticoagulation. In one study after concomitant surgical ablation, ILRs compared with conventional Holter monitoring facilitated more follow-up antiarrhythmic management, including cardioversions and catheter ablation procedures, which were associated with a trend toward higher sinus rhythm rates at 1 year. 942 Implantable pacemakers or defibrillators with atrial leads allow the burden of AF to be assessed by tracking the number and duration of mode-switch episodes. 963,964 These devices can also assess long-term AF burden, burden trends, and late or asymptomatic recurrences. 940,965,966 The ability to record intracardiac atrial electrograms provides excellent sensitivity and specificity for the diagnosis of atrial arrhythmias, especially with durations exceeding a few minutes. 937,967,968 Follow-up and Monitoring Guidelines for Routine Clinical Care There is a consensus among the writing group members that all patients who undergo catheter ablation of AF, regardless of whether they are enrolled in a clinical trial, should be seen in follow-up a minimum of 3 months following the ablation procedure. There is also consensus that all patients who undergo catheter ablation should be seen by some type of physician (family physician, internist, cardiologist, or electrophysiologist) on an annual basis thereafter. These ongoing interactions with the medical profession allow the patient’s clinical status to be evaluated, including an assessment of the presence or absence of AF as well as their stroke risk profile and anticoagulation needs. These interactions also provide an opportunity to focus on the treatment of associated diseases and lifestyle modifications. These recommendations are slightly modified from the previous edition of this document, which advised that all patients who undergo catheter ablation of AF, regardless of whether they are enrolled in a clinical trial, should be seen in follow-up at a minimum of 3 months following the ablation procedure, and then every 6 months for at least 2 years. A 12-lead ECG was recommended at all follow-up visits and more intense monitoring driven mainly by the clinical impact of AF detection with strict monitoring necessary (suspected rate-related cardiomyopathy). This modification of our writing group recommendations reflects, in part, data from real life clinical practice. 969 This European study revealed that one-third of the 12-month follow-up evaluations were performed by telephonic contact, only 87.2% of the patients had at least one ECG during the follow-up, and the patients with continuous monitoring of ≥24 hours (Holter- or implanted monitoring systems) represented only 57.4% of the population. Explanations of this gap between prior expert consensus recommendations and routine clinical practice might reflect the current disconnect between indications for catheter ablation and clinical outcomes of the procedure. Another factor can be cost. On one hand, the main indication for catheter ablation is symptomatic AF and decisions regarding continuation of anticoagulation therapy should be based on the patient’s risk factors for stroke and not on the presence of or type of AF. At the same time, transtelephonic or long-term monitoring is at times recommended after ablation to capture even asymptomatic episodes of AF to evaluate the need to continue anticoagulation. The majority of writing group members do not believe that data currently exist to support this common practice of making decisions regarding anticoagulation based on the presence or absence of AF (see Section 7). A significant amount of information has accumulated showing that cardiac risk factors such as obesity, sleep apnea, and hypertension are associated with structural and electrical remodeling of the atria, which forms the substrate leading to AF development and progression (see Section 3). The recommended indefinite annual follow-up visits with a health care professional allow for the evaluation and treatment of associated diseases and lifestyle modification rather than monitoring of the rhythm itself. Early Recurrence After Ablation Definition and Incidence Early recurrences of AF after AF ablation has been defined as any recurrence of AF >30 seconds during the first 3 months of follow-up. Late recurrence has been defined as any recurrence of AF >30 seconds between 3 and 12 months after AF. 141,142,143 In using the term early recurrence of AF (ERAF) it is recognized that the early recurrence might be AFL or AT. Although we considered defining a new term, early recurrence of ATAs, post-AF ablation, for simplicity we have employed the term early recurrence of AF. Throughout the document and this section of the document, we note that recurrences can present in the form of AF, flutter, or tachycardia. Early recurrences of AF after RF catheter ablation have been reported in up to 50% of patients within the first 3 months of AF ablation. 253,329,436,684,932,935,970,971,972 Because these arrhythmias do not definitively indicate therapy failure over the long term (only half of these patients will manifest later recurrences), this period is also referred to as the blanking or therapy stabilization period. 935,973 It is also important to recognize that the later AF recurrences are observed during the blanking phase, the lower the chance of long-term success. 935 Causes of Recurrences The pathophysiological mechanisms of these early recurrences are attributed to various mechanisms: primarily incomplete isolation of the PVs, 973,974 acute inflammatory changes owing to energy delivery, 755 recovery of conduction in a previously isolated PV, 448,622,975 modification of the ANS, changes in the atrial substrate, and delayed effect of RF ablation due to lesion consolidation. 257,258 Early Recurrence as a Predictor of Failure The occurrence of atrial arrhythmias early after ablation does not necessarily indicate treatment failure later during follow-up. 974 Nevertheless, early recurrences have been shown to predict arrhythmia recurrences late after catheter ablation of AF in some patients. 260,329,935,976,977,978 Management of early recurrences is controversial and has been treated by AADs, corticosteroids, early cardioversion, or repeat catheter ablation. Antiarrhythmic Drugs Because early AF recurrence usually peaks within the first few weeks following PVI, the temporary routine administration of AADs in the immediate postablation period has been proposed as a potential preventive strategy. 1,979 Although the true efficacy of this approach is unknown, studies have suggested that transient AAD use does not prevent late arrhythmia relapses. 935,980 The 5A study randomized 110 consecutive patients with PAF undergoing ablation to empirical AAD therapy vs no AAD therapy for the first 6 weeks after RF catheter ablation. 980 The authors noted a significantly lower incidence of clinically significant atrial arrhythmias (AF >24 hours or associated with severe symptoms), cardioversions, and arrhythmia-related hospitalization during the 6-week treatment period (13% vs 28% in the AAD vs non-AAD group; P 3 was the only independent predictor of an ablation failure. Therefore, currently, reablation should be considered in clinical practice after two cardioversions have been performed, because of the high likelihood of recurrent arrhythmias. Early Reablation Performance of early reablation reduces the incidence of further recurrences, but the overall number of procedures is higher in the medium-term follow-up. Two studies evaluated the use of early reablation on long-term freedom from AF in patients with ERAF. 141,142,143,989,993 In 302 consecutive patients with RF ablation for medically refractive AF, 151 experienced an ERAF, 61 of whom underwent reablation within the first month (e.g., early reablation group). The remaining 90 patients had a repeat procedure at least 1 month after the index ablation. During a mean follow-up of 11 ± 11 months, patients with early reablation had a lower rate of recurrences (51% vs 91%, P 75 years, 55% of whom had PAF, 127 (73%) maintained sinus rhythm after a single procedure, with an acute major complication rate of 1%. 1037 Another study evaluated catheter ablation for AF in 103 octogenarians with paroxysmal, persistent, or long-standing persistent AF compared with patients 45 years. In this study, the younger patients had lower rates of complication, shorter hospital stays, and lower rates of AF recurrence and AAD than older patients. Together, these studies suggest that AF ablation might be both safer and more effective in younger patients compared with “average” or older AF patients, although this result could be due in part to a lower burden of cardiac and noncardiac comorbid diseases. It has been suggested that AF ablation might more readily be considered first-line rhythm control therapy in younger rather than older patients; however the evidence base for making such a recommendation is not strong. The recommendations for AF ablation in young patients are shown in Table 2. Outcomes of AF Ablation in Women Multiple studies have found that women are more symptomatic from AF, have a lower QOL, and are less tolerant of AADs than men. 806,1046,1047,1048,1049 However, the rate of referral of women for catheter ablation of AF is significantly lower than men, and women are referred much later after failing more AADs. 920 There has not been consistent evidence to support female sex as a predictor of recurrence after AF ablation, based on multiple univariate and multivariate analyses. 252,1050,1051 A systematic review of predictors of AF recurrence after catheter ablation reported that none of the 23 studies found female sex to be a predictor of recurrence. 1050 At least four major studies have specifically examined outcomes after ablation of AF in women. A large, retrospective multicenter study involved 3265 consecutive patients with drug-refractory AF who underwent PVI. 289,290,291 Women constituted a much lower percentage of the patients referred for ablation, were referred later for ablation, had failed more AADs, more often had hypertension, and were older at the time of the procedure. After 24 ± 16 months of follow-up, the women had significantly lower success rates than the men, defined as single-procedure freedom from recurrent AF off AADs (68.5 vs 77.5%; P 60 mm. Among these 20 studies, four reported a significant association between larger LAD and a higher rate of recurrence of AF. Among 21 studies that examined the presence of structural heart disease as a predictor, only one reported a significant association at 12 months of follow-up. Most studies examined sex, and no association between recurrence and sex was found. Only one of 22 studies reported an independent association between age and recurrence. Cost-Effectiveness of AF Ablation The cost-effectiveness of AF ablation has been evaluated in a number of individual studies and several systematic reviews. 1118,1119,1120,1121,1122,1123,1124,1125 The costs of AF ablation procedures can vary widely, depending on the treatment setting and the actual equipment used. 409,1126 Estimates of the cost-effectiveness of AF ablation can vary further based on a number of additional factors, including the patient population, the severity of symptoms, the analytic time horizon, and assumptions about the impact of AF ablation on QOL, stroke, and other clinical outcomes. One issue supporting the potential cost-effectiveness of AF ablation is that the costs of ablation are at least partly offset over time by reducing long-term, arrhythmia-related health care resource utilization for patients not treated with ablation, as supported by some empirical evidence. 90,476,1033,1127 However, most formal cost-effectiveness studies have not found AF ablation to be cost neutral or cost saving in the short to intermediate term. The majority of published cost-effectiveness studies have compared AF ablation to AADs as second-line therapy in patients with PAF. 1119,1120,1122,1124,1128,1129 In general, these studies have reported acceptable cost-effectiveness ratios—in the range of $27,000 to $59,000 (Canadian) per quality-adjusted life year (QALY) gained over 5-year time horizons. 1122,1128 Results would be more favorable if ablation were found to significantly reduce the risk of stroke. 1118 U.S. experts have recently indicated that cost-effectiveness ratios below $50,000 per QALY indicate high value, and between $50 and $150,000 indicate intermediate value. 1130 Less is known about the cost-effectiveness of ablation in the first-line setting or in patients with persistent or long-term persistent AF. One report based on the First Line Radio-frequency Ablation Versus Antiarrhythmic Drugs for Atrial Fibrillation Treatment (RAAFT) pilot study suggested that costs for patients initially treated with drugs would catch up to those for patients treated with ablation within 2 years due to a very high rate of crossover. However, another more detailed cost-effectiveness study modeled after the MANTRA-PAF trial population indicated that AF ablation might only be cost-effective as first-line therapy in younger patients. 1125 Assessments of cost-effectiveness at present rely greatly on extrapolations from clinical trials with limited follow-up duration and sample sizes, necessitating assumptions about key clinical benefits. Robust data from larger, longer studies will be needed to refine cost-effectiveness estimates. Section 10: Complications Overview Catheter ablation of AF is one of the most complex interventional electrophysiological procedures. AF ablation by its nature involves catheter manipulation and ablation in the delicate thin-walled atria, which are in close proximity to other important organs and structures that can be impacted through collateral damage. It is therefore not surprising that AF ablation is associated with a significant risk of complications, some of which might result in life-long disability and/or death. In this section of the document we will review the complications associated with catheter ablation procedures performed to treat AF. The complications are defined and their mechanisms explored. Emphasis is placed on both those complications that occur most frequently as well as those very infrequent complications that have the potential to result in the greatest disability and/or death. Means of avoiding complications are described and recommendations are made regarding management should the complications occur. It is noteworthy that the publications from which these data are derived come from high-volume centers where one would expect the incidence of complications to be lower than in lower-volume centers. As the practice of AF ablation grows with an increasing number of low-volume centers performing these procedures, it is likely that the true complication rate of AF ablation will be higher than described here. Furthermore, other data such as those derived from the two worldwide surveys of catheter ablation of AF were provided voluntarily and, again, are therefore likely to underestimate the true complication rate. 806,920 It is notable that a recent paper reported on the trends in hospital complication rates associated with AF ablation between 2000 and 2010 based on the Nationwide Inpatient Sample involving 93,801 procedures. 921 The overall incidence of complications was 6.29%—increasing from 5.3% in 2000 to 7.5% in 2010. The in-hospital mortality was 0.46%. Not surprisingly, lower operator and hospital procedure volume was an important predictor of complications. These data are a stark reminder that our efforts to eliminate complications associated with AF ablation are incomplete and there is more work to do. As our experience with AF ablation continues to grow, new complications are recognized and are reviewed here. These include stiff LA syndrome, cough, pulmonary injury, gastric hypomotility, and sinus tachycardia. Once again, the writing group strongly recommends that standardized reporting of complications be part of all published reports on AF ablation. In this document, we have provided definitions of the most important complications associated with AF ablation (Table 8). We hope these definitions and reporting standards can be incorporated in the design of future clinical trials of AF ablation. Shown in Table 9 is an overview of the incidence, prevention, diagnosis, and management of selected complications, and Table 5 presents signs and symptoms associated with various complications early and late postablation. Cardiac Tamponade Cardiac tamponade remains the most common potentially life-threatening complication associated with AF ablation. 921 A recent paper reported on the trends in in-hospital complication rates associated with AF ablation between 2000 and 2010 based on the Nationwide Inpatient Sample involving 93,801 procedures. 921 In this analysis, the overall incidence of a “pericardial complication” was 1.5%. The incidence of pericardial complications increased from 0.74% in 2000 to 2.24% in 2010. 921 The markedly higher incidence of cardiac tamponade during AF ablation compared with routine cardiac electrophysiology procedures can be attributed to a number of important procedural differences, including extensive intracardiac catheter manipulation and ablation, the common need for two or more transseptal punctures, and the need for systemic anticoagulation. 806,920,921,1131,1132,1133,1134,1135 The most common causes of cardiac perforation leading to cardiac tamponade during AF ablation are (1) misdirected transseptal punctures either with punctures performed too posteriorly exiting the RA into the pericardium before entering the LA or punctures exiting the LA via the roof, LAA, or the lateral LA wall; (2) direct mechanical trauma, especially through the LAA; and (3) overheating during RF energy delivery, with or without the development of a steam pop. Excessive power, temperatures, and CF might also be contributory. The need for periprocedural anticoagulation (with the use of interrupted or uninterrupted OAC strategies) and for intra-procedural anticoagulation (with the infusion of intravenous heparin to achieve a stable ACT above 300 seconds throughout the procedure duration) can exacerbate the bleeding risk and increase the volume of bleeding following the occurrence of one or more of the causes above. One initial large study reported that uninterrupted VKA anticoagulation therapy did not result in a higher incidence of tamponade compared with interrupted VKA anticoagulation therapy with bridging heparin. 532,533 This observation was further corroborated by two meta-analyses. 399,400,401,1136 Another study compared the outcomes of 23 patients who developed pericardial tamponade with an INR 2. No difference was observed in the initial pericardial drainage, or the duration of drainage; no patients required surgery. 1137 A more recent shift in periprocedural anticoagulation strategies during AF ablation involves performing AF ablation on uninterrupted NOAC therapy. The results of the RE-CIRCUIT study, which was a head-to-head comparison of performing AF ablation on uninterrupted dabigatran vs uninterrupted warfarin, were recently published. 841 This study randomized 704 patients across 104 sites to these two anticoagulation strategies. The incidence of major bleeding events during and up to 8 weeks postablation among the 635 patients who underwent AF ablation was significantly lower with dabigatran than with warfarin (5 patients [1.6%] vs 22 patients [6.9%]; absolute RD -5.3%; RR reduction 77%). It is notable that there were six patients with cardiac tamponade in the warfarin arm vs one in the dabigatran arm. All the patients with cardiac tamponade underwent successful pericardiocentesis with no need for surgical drainage. No strokes or other thromboembolic events occurred in the dabigatran arm compared with one TIA in the warfarin arm. No patients in the dabigatran arm required the specific reversal agent idarucizumab. Another smaller prospective trial of 250 patients that randomized patients to undergoing AF ablation on uninterrupted rivaroxaban versus uninterrupted warfarin has been published. 842 The incidence of major bleeding was low (0.4%), and no patient developed pericardial tamponade. A recent meta-analysis reported that performance of AF ablation on NOACs was associated with a lower risk of minor bleeding and no major differences in the risk of stroke or TIA, cardiac tamponade, or groin hematomas. 1138 Another recent study described the outcomes of 16 patients who developed a pericardial effusion while taking an uninterrupted Xa inhibitor. Eleven occurred in the periprocedural setting and 5 occurred between 1 and 28 days postprocedure. All the patients underwent pericardiocentesis. Protamine and 4-factor prothrombin complex concentrate were given to all periprocedure cases. Two patients required surgery. There were no deaths in this series. The incidence of tamponade might be as high as 6% 1135 and as low as 0%. The risk factors for tamponade identified in this study were linear ablation lesions and higher ablation power. A “pop” was heard during eight of these 10 cases of tamponade. Another large series reported cardiac tamponade during 15 of 632 ablation procedures (2.4%). 1134 Two of these patients required surgical intervention. In contrast to the prior study, no “pop” was reported. The two worldwide surveys of AF ablation reported a 1.2% and a 1.3% incidence of cardiac tamponade, respectively. 806,920 A recent meta-analysis of ablation procedures reported a 0.9% incidence of tamponade. 1139 Women were 1.83-fold more likely to develop tamponade compared with men. A reciprocal relationship between center volume and the incidence of outcomes of cardiac tamponade was observed. Overall, 16% of tamponade cases required surgery, with lower rates of surgery in high-volume centers. 1139 A meta-analysis of CBA with data on 1308 procedures reported an overall incidence of cardiac effusion or tamponade of 1.5%. 482 A more recent prospective RCT of CBA vs RF ablation reported an incidence of tamponade of 1.3% in the RF arm and of 0.3% in the CB arm. 489 Although it was hoped the recent introduction of force-sensing catheters would reduce the rate of tamponade, this has not been confirmed in clinical trials. The incidence of cardiac tamponade was 2.5% among 161 patients in the safety cohort of the recently published SMART-AF trial of the Smart Touch catheter. 673 And in the TOCCASTAR trial, which randomized patients to ablation with a force-sensing catheter (Endosense) or a standard irrigated RF catheter, no difference in the incidence of cardiac tamponade was observed in the two arms (0.66% vs 0.7%, P = NS). 655 It is important to recognize that the presentation of cardiac tamponade might be delayed and can occur any time from an hour after the procedure to weeks later. 1034,1139 The incidence of delayed tamponade was 0.2% in the worldwide survey report. 1034 Most, but not all, patients presented with warning symptoms and 13% of patients presented with hypotension and shock. Cardiac tamponade presents either as an abrupt dramatic fall in BP, or more insidiously, as a gradual decrease in BP. In the latter case, administration of fluid might return the BP to normal before it subsequently declines. However, it is vital that operators and staff be vigilant to the development of cardiac tamponade, as a delay in diagnosis can be fatal. Sixty percent of the writing group members use an arterial line for BP monitoring during the AF ablation procedure. The development of hypotension in any patient should be assumed to indicate tamponade until proven otherwise by immediate ECG. An early sign of cardiac tamponade is a reduction in the excursion of the cardiac silhouette on fluoroscopy with a simultaneous fall in systemic BP. Ninety percent of the writing group members have an echo machine in their EP laboratory. Sixty percent of the writing group members routinely image the heart with an echocardiogram prior to the patient leaving the procedure room. Twenty percent of the writing group members routinely obtain an echocardiogram of the heart prior to discharge. ICE has been reported to allow earlier detection of pericardial effusion. It is important to recognize that small, asymptomatic pericardial effusions are commonly observed following AF ablation procedures. ICE imaging has the potential to detect pericardial effusion earlier. A survey of writing group members reveals that 53% of members routinely employ ICE imaging during AF ablation. Our survey revealed that ICE was being used routinely by 87% of the writing group members in the United States and Canada as compared with 13% of the writing group members from other countries. Monitoring filling pressures in the LA and RA can be helpful in order to evaluate progression of the effusion and/or effective drainage of the pericardial collection. Ninety-three percent of the writing group members hospitalize their AF ablation patients for at least one night following their procedure. The majority of episodes of cardiac tamponade can be managed successfully by immediate percutaneous drainage and reversal of anticoagulation with protamine. In patients anticoagulated with warfarin, fresh frozen plasma is often administered. And in patients on an Xa inhibitor, 4-factor prothrombin complex concentrate is often appropriate. For patients on dabigatran, the reversal agent idarucizumab is now available worldwide and provides the opportunity to immediately reverse the anticoagulant effects of dabigatran. 844 Factor Xa inhibitors can be reversed with andexanet alfa (currently not approved for clinical use). 845 Percutaneous drainage is best achieved by subxiphoid Sel-dinger puncture of the pericardial sac and placement of an intrapericardial catheter. The pericardial tap can be performed either with fluoroscopic guidance based on anatomic landmarks or with echo guidance. 1140 After initial aspiration, the BP promptly returns to normal. Once the pericardial space has been drained, the patient needs to be monitored for ongoing bleeding with the drainage catheter. The drainage catheter is typically left in place for at least 12 hours postablation. In rare cases, if there has been a tear, percutaneous drainage might be inadequate, and surgical drainage and repair could be necessary. 1134 One recent meta-analysis reported that 16% of cases of cardiac tamponade required surgical intervention. 1139 It is for this reason that AF ablation procedures should only be performed in hospitals equipped or prepared to manage these types of emergencies with access to emergency surgical support when required. Three cases have been reported of emergent drainage of a pericardial effusion through a sheath, either inadvertently or purposely placed into the pericardial space using an endocardial approach, although this would not be considered to be a standard approach. 532,533,1132,1141 Early recognition and rapid appropriate treatment of cardiac tamponade is mandatory to prevent irreversible deterioration in perfusion of the brain and other important organs. In a dedicated worldwide survey, cardiac tamponade was reported to be the most frequent cause of periprocedural death, with 25% of all fatalities occurring in association with this complication. 908 PV Stenosis PV stenosis is a well-recognized complication of AF ablation that results from thermal injury to the PVs, including the media, intima, adventitia, and PV musculature. Since first reported in 1998, numerous studies have sought to determine the incidence, cause, diagnostic strategy and treatment approach for PV stenosis. 434,927,1142,1143,1144,1145 Although the precise pathophysiological mechanisms are still uncertain, a progressive neointimal proliferation and myocardial fibrosis resulting in endovascular contraction has been reported after extensive radiofrequency energy ablation (RFA) to canine PVs. 1146 PV stenosis has been described for both point-by-point RF ablation as well as CBA. 244,462,482,928,1146,1147 To the best of our knowledge, significant PV stenosis has not been reported with the laser balloon system. 498,503 There are controversial data regarding any impact that RF power output has on the rate of PV stenosis. 244,1147 The incidence of PV stenosis might be somewhat lower with CB AF ablation than with RFA. 1148,1149 In experienced hands, however, PV stenosis has become an increasingly uncommon complication with either ablation technology. 489 The highest risk for PV stenosis is associated with RFA close to the PV orifices and/or within the PVs, with a 5.6-fold higher incidence in comparison with antral ablation. 1147 Ablation within the PVs should be avoided, but can occur due to shifts in the 3D electroana-tomic map, respiratory motion, poor catheter stability, and/or an inexperienced operator. The published incidence of PV stenosis varies widely, from 0% to 40%. 434,505,778,1142,1144,1150,1151 This variation results from differences in the ablation technique, definitions of PV stenosis, the intensity of screening for this complication, and the date the study was performed. When PV ablation for treating AF began in the late 1990s, investigators were unaware that PV stenosis was a potential complication. In contrast, operators today understand that PV stenosis can be prevented by avoiding RF energy delivery within a PV. This increased awareness and improvements in imaging modalities have enabled better identification of the true PV ostium and have resulted in a dramatic reduction in the incidence of PV stenosis. 1141,1147 The incidence of symptomatic PV stenosis in experienced hands approaches zero, although the incidence of asymptomatic PV stenosis or PV narrowing might be higher. Symptoms usually occur weeks to months after the ablation procedure. 927,1152 Prominent symptoms are dyspnea, hemoptysis, cough, (recurrent) pulmonary infections or pneumonia, and chest pain. 1142,1143,1152 These have often led to a misdiagnosis of pneumonia, pulmonary embolism, or even lung cancer; thus, patients should be told of the importance of returning to their ablation center if such signs or symptoms develop. There are data showing a progression of stenosis during 3 months after RFA despite a normal imaging examination at 1 month after the index procedure. Furthermore, severe stenosis can also remain asymptomatic. 927 According to the percentage reduction of the luminal diameter, the severity of PV stenosis is generally defined as mild ( 70%). In this consensus statement, we recommend that a significant PV stenosis be defined as a >70% reduction in luminal diameter. PV stenosis can develop in any PV; and in some patients, multiple PV stenoses occur. 927,928,1143, 1152 It is unclear whether such patients are more prone to develop PV stenosis compared with others. PV stenosis can be diagnosed by CT imaging, MRI, perfusion scans, TEE, or pulmonary venography. The preferred imaging modality is MRI or CT because location and severity of PV lesions can be precisely visualized. Advantages of MRI include the fact that pulmonary perfusion data can be obtained simultaneously and that the diagnostic procedure is free of radiation. Eleven percent of the writing group members routinely obtain a CT or MR scan several months postablation to screen for asymptomatic PV stenosis. Although the incidence of PV stenosis has decreased over recent years, it remains a significant complication because it is difficult to treat and, rarely, it can lead to death. It is notable that 51% of the writing group members report having had a patient at their center develop PV stenosis requiring intervention. Most of these procedures were performed more than a decade ago. The indication for intervention is guided predominantly by the presence or absence of symptoms. Asymptomatic or mild symptomatic PV stenosis should be managed conservatively with watchful waiting, given symptomatic amelioration has been observed after PV stenosis or occlusion without treatment and indicates collateral formation or recruitment. 1153 For symptomatic patients, PV angioplasty should be considered. In patients with more than one PV stenosis, perfusion imaging may be applied to identify the “culprit” lesion. The dilation procedure is often complex, especially if the target PV is completely occluded with failed visualization from direct angiography via the LA as well as antegradely via pulmonary artery angiography. Electroanatomical 3D mapping with registration of the anatomy of the LA and the PVs, as well as fusion with the reconstructed LA from the imaging scan before the index procedure, enables a precise localization of the occluded PV. 1154 Baseline CT or MRI is more helpful in defining the PV anatomy. Many PV stenoses are rigid and difficult to dilate. Even after acutely successful angioplasty, PV restenosis occurs in up to 50% of cases. 927,1142,1143,1152,1155 Stent sizes of 9 mm or more, and especially drug-eluting stents, revealed significantly better results, although drug-eluting stents of this size are not available. 1142,1143,1144,1156 Whether or not primary stenting of PV stenosis offers better results than angioplasty alone has now been systematically studied by several groups. 1144,1155 The risk of restenosis is significantly less with PV stenting, providing a stent of 8–10 mm in diameter can be used. A further problem is the small sample size of the published case series. Complications of interventional treatment of PV stenosis include LA perforation with or without tamponade, but also PV dissection with massive bleeding, stent embolization, and stent thrombosis. 1142,1143 There are limited data regarding the need for and intensity of anticoagulation and antiplatelet therapy. For cases in which anticoagulation is otherwise indicated for AF, a regimen including the addition of clopidogrel is most commonly used. Without the indication for anticoagulation, warfarin and clopidogrel should be combined. The duration of anticoagulation needed remains unclear. In the case of restenosing PVs, anticoagulation for life might be necessary. In the setting of stable PV stents over the course of 1–2 years, clopidogrel and, subsequently, warfarin can be discontinued. The role of NOACs in PV stenosis has not been readily studied. Surgical patch repair of primary PV stenosis in children reveals a 5-year success rate of 67%, with an in-hospital mortality of 10%. 1157 Only one case of surgical treatment of severe PV stenosis with patch implantation after catheter ablation has been reported. 1158 Thus, it remains unclear whether the results are better than with conventional interventional treatment. Connecting the patch to the proximal end of the stenosis is difficult, because this end is buried in the lung parenchyma. Given this challenge, and the excessive risk, there is no foundation for recommending its use in patients with recurrent PV stenosis after AF ablation, and decision making cannot be based on a single case report. Even for patients with recurrent severe and persistent problems due to restenosis despite interventional treatment, recurrent infection and hemoptysis are uncommon, readily manageable, and the need for lobectomy or pneumonectomy is very rare. In the largest series of PV stenosis to date, both patients who underwent subsequent pneumonectomy at outside institutions died during or after surgery. 1155 Although lung transplantation can be considered in a case of congenital PV stenosis, 1159 this has never been required in AF-ablation patients. Dealing with patients with fibrosing mediastinitis and PV or peripheral artery (PA) stenosis is, in contrast, exceptionally difficult. 1160 Successful PV angioplasty or stenting usually results in a significant relief of symptoms. 1142,1143,1144,1145,1155,1156 Thus, follow-up strategies and intensity should be based on symptoms. Patients with restenosis usually report an increase of complaints existing prior to the intervention. In such cases, MRI is recommended. There is an additional critical consideration in dealing with PV stenosis. With the decline in follow-up CT scans after AF ablation, the occurrence of serious stenosis, hemoptysis, permanent PV occlusion, scarring, lung infarction, and intraparenchymal hemorrhage has increased. Many such patients are being inappropriately evaluated for lung cancer because of the appearance of intraparenchymal hemorrhage. Candidate veins for intervention are also increasingly problematic. These are more difficult to open and have a higher restenosis rate, requiring repetitive re-intervention. Because of this, it is recommended that if a patient does not undergo a routine follow-up 3-month CT or MR, at a minimum, those with recurrent pulmonary symptoms after AF ablation should be scanned to exclude PV stenosis. Patients should also be routinely screened for symptoms at the time of follow-up evaluations. The take-home message is to identify PV stenosis before it becomes a serious problem. Atrial Esophageal Fistula, Atrial Pericardial Fistula, and Esophageal Hematoma Esophageal injury is one of the most important complications associated with catheter and surgical ablation of AF. In this section of the document we will focus on three types of esophageal injury: (1) esophageal hematoma, (2) atrial pericardial fistula, and (3) AEF. We will consider esophagopericardial fistula and AEF as one topic, and will focus mainly on this serious and often lethal complication of AF ablation. However, to be complete, we will also comment on the recently described complication of an esophageal hematoma. Esophageal Hematoma The esophagus can be injured directly as a result of trauma from a transesophageal probe. Esophageal hematoma is a recognized complication after a transesophageal echo study, which can be performed in association with the ablation procedure. 1161 A recent study reported that 0.27% of the patients who underwent an AF ablation with a preprocedure TEE experienced this complication. The predominant symptoms were pain on swallowing, regurgitation, and hoarseness, with an onset within 12 hours of the procedure. Fever and neurological symptoms were not present. The diagnosis was established by a CT scan, which ruled out an AEF and revealed a hematoma localized to either the upper esophagus or extending the length of the esophagus. Endoscopy can further confirm the diagnosis. Conservative management is advised. Long-term consequences of this complication include an esophageal stricture, esophageal dysmotility, and vocal cord paralysis. 1161 AEF and Atrial Pericardial Fistula Esophageal ulceration, perforation, or development of a left AEF or atrial pericardial fistula, have been reported after both catheter ablation of AF and surgical ablation of AF using unipolar RF current. 806,866,920,1162,1163,1164,1165,1166,1167,1168,1169 It is a possible complication after catheter ablation using any energy modality that produces transmural atrial lesions. Although early reports showed AEF resulting from RF ablation, more recently, AEFs have also been reported after CBA. 877,878,879,1170 An adequately powered study examining the relative frequency of this complication with the two primary ablation modalities has not yet been performed. AEFs have also been reported following ablation with a focal ultrasound balloon ablation system that is no longer clinically available. 705,1167 Esophageal erosion has also been reported with a circular multielectrode irrigated RF ablation system. 1171 It is notable that 51% of the writing group members report having had a patient at their center develop an AEF following AF ablation. It should be clear, however, that the occurrence of an esoph-ageal ulcer is not the same as an AEF. Although AEFs can be accompanied by ulcers, the presence of an ulcer is not predictive of an AEF. Occurring in 10%–40% of patients undergoing an AF ablation, the prevalence of an AEF is closer to one in one thousand in those with an ulcer. Although the precise mechanism of esophageal tissue injury is not understood, potential mechanisms include direct thermal injury, acid reflux, infection from the lumen, and ischemic injury through thermal occlusion of end arterioles. It has been hypothesized that vagal damage resulting from ablation on the posterior LA wall can cause gastroesophageal reflux by damaging the vagal nerves that run along the esophagus, altering the lower esophageal sphincter pressure. This hypothesis proposes that high esophageal acid production could contribute indirectly to the formation of AEFs. 1172,1173 This hypothesis is attractive; however, one study that attempted to validate it by measuring esophageal acid levels post-AF ablation was negative. 1173 The prevalence of esophageal reflux and an AEF are also very different. Although the development of an AEF following AF ablation is a very uncommon complication, its importance rests in the lethality of this complication. The Updated Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial Fibrillation reported an AEF in six patients (0.04%). 920 This incidence was similar to a separate survey of members of the Heart Rhythm Society. In this survey, an AEF was reported in 6 of 20,425 patients (0.03%). 1168 All six of these patients experienced major cerebrovascular events, and five (83%) died. In contrast to an AEF, which is very rare, subclinical injury to the esophagus is extremely common following AF ablation. A more recent study reported an AEF incidence of 0.11%. In a number of studies, an endoscopy has been performed to screen for esophageal injury 1–3 days following AF ablation. 1174 Esophageal tissue injury has been reported in up to 50% of patients. 637,882,1175 Observed asymptomatic esophageal ulcers were usually healed on repeat endoscopy at 2–3 weeks. 1176 One study reported endoscopy performed on 267 patients who underwent RF ablation. The power on the posterior wall was limited to 25 W. Among these patients, 6 (2.2%) had either erythema (n = 2) or a necrotic ulcer (n = 4) on endoscopy. Multivariate analysis revealed that the distance between the LA and the esophagus was the only independent predictor, although an LA isthmus line and CS ablation showed a trend. 900 After treatment with a PPI (pantoprazole or esomeprazole) and sucralfate, all recovered without development of an AEF. One study reported a higher incidence of esophageal injury among patients undergoing AF ablation with general anesthesia compared with conscious sedation. 637 It has been proposed that this relationship reflects the absence of pain feedback and reduced esophageal motility resulting from general anesthesia. The clinical manifestations of an AEF usually present 2–4 weeks after the ablation procedure. The most common symptoms are fever and recurrent neurological events (septic emboli), but patients can present with septic shock, esopha-geal bleeding, or death. A recent case series of 53 patients who developed an AEF following AF ablation reported a mean interval between the procedure and presentation of 20 ± 12 days, ranging from 2 to 60 days. In this series, fever was the most common presenting symptom, followed by neurological deficits and hematemesis. 1176 The preferred diagnostic modality is a chest CT scan. 1169,1176 It is important to recognize that a normal chest CT scan does not rule out the presence of an AEF with 100% sensitivity. Ongoing vigilance and evaluation are important if the clinical suspicion is high. Although a barium swallow can detect a fistula, its sensitivity is low. IV contrast is much more likely to demonstrate a lesion passing from the esophagus to the mediastinum, the pericardium, or the LA. If an AEF is suspected, endoscopy with air insufflation should be avoided, given that insufflation of the esophagus with air can result in a large air embolus, producing stroke or death. An alternative strategy, which some members of the writing group employ and which appears to have lower risk, is to use CO2 instead of air for insufflation in this setting. If CO2 were introduced into the LA, there would be little adverse consequence. The early recognition of an AEF can be missed due to the low awareness of this rare complication. It is important for patients to be educated as to warning signs and to contact their AF ablation center should any suggestive symptoms develop. Considerable efforts have been made to reduce the frequency of this complication. Approaches that have been proposed include avoiding ablation on the posterior wall of the atrium (or at least over the trajectory of the esophagus), reducing RF power on the posterior wall (to 25 W or less), using ICE to image the esophagus, and using an esophageal temperature sensor. 637,900 Many institutions use an esophageal temperature probe to prevent thermal injury; however, it is widely acknowledged that use of an esophageal temperature probe does not eliminate the risk of esophageal injury. 341,417,910 A survey of the writing group members shows that 87% use lower RF power on the posterior wall. This survey also reveals that two-thirds routinely use an esophageal temperature probe. Among those who use a temperature probe, one-third report using a temperature probe with multiple temperature sensors, whereas two-thirds use a probe with only one temperature sensor. It is important to recognize that the temperature probe should be as close as possible to the ablation catheter at all times during the procedure. Another variable concerns when to stop power delivery. Whereas some operators ablate until a predefined temperature has been met (e.g., 39°C or 40°C), other operators use a more conservative approach and terminate power when the esophageal temperature increases by as little as 0.2°. Esophageal temperature monitoring is also commonly used during CB AF ablation. Energy delivery is generally stopped when the esophageal temperature is lower than -20°C. An alternative approach to the prevention of this complication is to move the esophagus away from the site of ablation using an endoscope or stylet positioned through a chest tube. 894,895,1177 None of the writing group members employ this strategy. Other widely used strategies include the use of PPIs; although this approach is unproven, it has become a common approach. Seventy-two percent of the writing group members employ a PPI for 1–4 weeks following AF ablation. Use of PPIs is more common following RF ablation (95%) compared with CBA (54%). It is important to note, however, that this practice is based on the observation that esophageal ulcerations can be observed on endoscopy following ablation. There is no proof that this approach reduces the development of an AEF. Treatment of an AEF is a medical emergency that requires urgent surgical repair. 341,417,906,910,911,1169,1176,1178 Recent case series have reported an 83% to 100% mortality without surgical repair compared with a 34% mortality with surgical repair. 341,417,906,910,1176 Although several case reports have been published describing favorable outcomes with esophageal stent placement for treatment of an esophageal perforation or an esophageal pericardial fistula, the mortality rate for stent placement in a patient with a true AEF approaches 100%. 341,417,905,907,910,911 In summary, AEF is a rare but unpredictable complication with severe consequences that might only be mitigated by cautious use of energy on the posterior wall of the LA, early detection, and intervention. Prompt diagnosis and surgical treatment are typically required. Support for the use of esophageal stenting is limited, and progression of the AEF process can still occur despite this stenting procedure. Gastric Hypomotility and Periesophageal Vagal Nerve Injury Injury to the vagal anterior esophageal plexus can occur when RF energy is applied to the posterior wall of the LA, which can cause acute pyloric spasm and gastric hypomotility. Common symptoms include nausea, vomiting, bloating, and abdominal pain developing within a few hours to a few weeks after the ablation procedure. 1018,1020,1179,1180,1181 Some patients also experience sinus tachycardia. 1180 The incidence of symptomatic gastric problems can be as high as 17%. 1020,1181 One recent study reported that asymptomatic functional impairment of the upper GI tract occurred in 74% of patients. After AF ablation, although the abnormality is often asymptomatic, the time to recovery is variable, with some patients recovering within 2 weeks, but others requiring a much more protracted time to recovery. 536 The initial evaluation can include endoscopy or a barium swallow study to look for residual food after an overnight fast. CT shows marked gastric dilation. Solid food labeled with technetium-99 can demonstrate delayed gastric emptying. The 13C-acetate breath test has been reported to be a noninvasive alternative to scintigraphy. 1182 Real-time MRI has been used to assess gastric motility and pyloric spasm. 1179 In addition, electrogastrography can reveal gastric dysrhythmia with bradygastria in patients after ablation. 1183 The integrity of the vagal innervation to the gastrointestinal system can be assessed by the pancreatic polypeptide response to sham feeding. Patients with this complication exhibit an abnormal kinetic and peak response. The normal response is a biphasic increase in pancreatic polypeptide. Injury to the vagus nerve impairs the first phase of the response. 1017 After sham feeding, pancreatic polypeptide level elevation by less than 50% from baseline was considered as abnormal. Management of this complication depends on the severity of symptoms and whether gastric immotility or pylorospasm predominates. Small, low-fat, and low-fiber meals can alleviate symptoms. Intravenous erythromycin can be effective in the acute stage to improve diabetic gastroparesis but has not been evaluated post-AF ablation. 1184 Metoclopramide can be used to promote gastric motility for 1–3 months, but long-term treatment is associated with a risk of movement disorders. Botulinum injections or surgery might be required to alleviate pyloric spasm. 1185 In severe cases, surgery or gastric pacing might be required. 1185 Although there is no established method to prevent injury to the vagal nerves, the risk can be reduced by using the same techniques used to avoid an AEF, described earlier in this document. A recent report identifies higher BMI and limiting the power to 20–25 W on the posterior LA wall as protective against periesophageal nerve injury during AF ablation. 1020 Phrenic Nerve Palsy PN palsy is an important complication of AF ablation and results from direct thermal injury. 536,903,1017,1182,1183,1184,1185 The right PN is most commonly affected, given it descends in close proximity to sites of ablation in the SVC and both right-sided PVs (Figure 1). 536,903,1184,1185,1187 It courses slightly further from the RIPV so that injury during treatment of this vein is less common than that occurring with RSPV ablation. PN palsy is observed with all technologies for AF ablation, including RF, cryoablation, ultrasound, and laser ablation. 490,536,903,1017,1182,1183,1184,1185,1187 PN palsy can be asymptomatic or can cause dyspnea, tachypnea, cough, hiccups, and thoracic pain. The diagnosis is suggested when newly elevated hemidiaphragm with atelectasis of the ipsilateral lung base is observed on postprocedure chest radiograph. When suspected, diaphragm excursion should be evaluated using fluoroscopy (sniff test) or ultrasound to confirm the diagnosis. Of the writing group members, 64% report having had a patient at their center develop permanent PN palsy, and 36% of the writing group members report having had a patient at their center develop permanent PN palsy following AF ablation with RF energy. The most common scenario in which PN injury occurs is with CBA, with an incidence of transient PN palsy of 3.5%–11.2%. 462,1075,1188,1189 Permanent PN palsy resulting from CBA is far less common, with an incidence of 0.3% in the recently completed FIRE AND ICE trial. 490 PN palsy has also been reported with the laser-balloon ablation system. In the HeartLight study of the laser balloon, diaphragmatic paralysis secondary to PN injury occurred in 3.6% of the patients with the laser balloon and was more common than with RF ablation. Persistent PN paralysis at 1 year occurred in 1.8% of the patients. 503 The hot balloon ablation catheter employs a compliant balloon filled with saline that is inflated to occlude the PV. 706 Because of the mechanism of balloon heating, the possibility of hot spots forming in deeper tissue planes or in collateral structures such as the esophagus is unlikely. 707 The main reported complications with this technology were PN palsy (3.4%) and PV stenosis (1.7%). 708 A recent, prospective, multicenter clinical trial compared the outcomes of hot balloon ablation vs AAD therapy for PAF. 706 The incidence of PN injury was 3.7%. Several mechanisms have been proposed to explain the increased incidence of balloon-based (CB, laser balloon, hot balloon) AF ablation and PN injury. First, wedging or exerting force to direct the balloon into the RSPV for complete PV occlusion can distort the anatomy and decrease the distance between the RSPV endocardium and the right PN. 1190 Second, a small balloon size relative to PV diameter can increase the likelihood of distal ablation in the vein. 779 Third, the broader, circumferential thermal gradient and use of additional freeze cycles can increase risk of dose-dependent nerve palsy. 1075 Studies have shown a higher risk of PN injury associated with the smaller 23-mm balloon compared with the larger 28-mm balloon with more proximal energy application. 462,482 The smaller balloon is potentially advanced further within the PV, causing distortion of the anatomy, creating a higher susceptibility to PN thermal injury. PN palsy can also occur during WACA using RF energy. This likely results from thermal injury to the PN as it courses anterior to the right PVs. The second most common scenario of PN palsy is during electrical isolation of the SVC using point-by-point RF ablation; the reported incidence is 2.1%–10%. 1191,1192 Ablation within a persistent left SVC can result in left PN paralysis, but appears rarely, and has been associated with the use of CB. 1193 Injury to the left PN during isolation of a persistent left SVC was not observed in several case series using RF energy. 232,1042,1194,1195 Very rarely, ablation at the roof of the LAA can result in left PN damage 1184 ; however, it was not observed in a large study in which LAA isolation was performed using RF ablation. 532,533 The incidence of PN palsy is 0.17%–0.48% with PV antrum isolation using RF ablation, even though the PN is found within the typical WACA and carina lines of the right-sided PVs in 30% of patients. 808,920,1184,1196 This highlights the importance of factors other than anatomic proximity alone contributing to the higher incidence of injury with CB. A number of strategies have been employed to prevent PN palsy. These include limiting ablation to antral regions with various balloon maneuvers; preablation high-output pacing to establish whether the PN can be captured from the proposed ablation site before ablation; PN mapping with anatomic tagging of its course using an EAM system to guide the modification of the ablation lesion set; and monitoring of diaphragmatic excursion with abdominal palpation, fluoros-copy, or intracardiac ultrasound while pacing the PN from the SVC or subclavian vein during ablation. 1196 Monitoring the effects of pacing the right PN is now considered a standard part of CBA and should be considered during SVC isolation using RF energy. Of the writing group members, 96% report employing this technique when performing CB AF ablation. Finally, diaphragmatic electromyography for direct monitoring of diaphragmatic compound motor action potentials (CMAP) during ablation is a technique for early detection of PN palsy that has been reported to reduce incidence of palsy. 1197,1198 CMAPs are recorded using body surface electrodes, esophageal electrodes, or a diagnostic catheter positioned in the hepatic vein. A decrease in the amplitude of the myopotential by 30% is more sensitive than abdominal palpation for predicting the subsequent reduction in diaphragmatic excursion and nerve palsy. 1199 Energy delivery should be interrupted immediately at the first sign of PN injury. One-third of the writing group members report employing this technique when performing CB AF ablation. One-third of the writing group members also report pacing anterior to the right PVs to tag the PN when performing AF ablation using RF energy. PN palsy can be asymptomatic or can cause dyspnea, tachypnea, cough, hiccups, and thoracic pain. 903,1017,1184,1187 The diagnosis is suggested when newly elevated hemidiaphragm with atelectasis of the ipsilateral lung base is observed on postprocedure chest radiograph. When suspected, diaphragm excursion should be evaluated using fluoroscopy (sniff test) or ultrasound to confirm the diagnosis. There are various stages of PN palsy, ranging from detectable decrease in CMAP before a reduction in diaphragmatic excursion is perceived to persistent paralysis. With CBA, most PN injuries are transient and resolve within minutes. 903,1184 In patients with persistent nerve palsy, most recover nerve function within weeks and almost all by 12 months, although 18–24 months might be required in some patients. 1200 In a large meta-analysis of 22 studies enrolling 1308 patients undergoing CBA, 4.7% had persistent PN paralysis after the ablation procedure, but only 0.37% had paralysis lasting longer than 1 year. 482 The pathophysiology of the palsy differs by type of ablation energy. With RF ablation, there is a dose-dependent response, and permanent palsy is characterized acutely by edema, coagulation, and homogenization of cytoplasmic contents and smearing of nuclear chromatin. 536 With CB, the palsy is also dose-dependent; however, histopathology studies have shown Wallerian degeneration of large myelinated axons, and that axonal regeneration accounts for late recovery of nerve function. 1201 There is no active treatment known to facilitate PN healing; however, in symptomatic patients with permanent nerve palsy, diaphragmatic plication can improve dyspnea and functional status. Stroke, TIA, and Silent Microemboli Stroke and TIA Embolism of air or thrombus is one of the most significant complications of AF ablation, and both are potential causes of cerebral, coronary, and peripheral vascular compromise. The incidence of thromboembolism associated with AF ablation is reported to be between 0% and 7%. 242,489,503,532,533,655,673,796,798,799,806,920,921,1202,1203,1204 More than two-thirds of the clinical trials reviewed for preparation of this document reported one or more cerebro-vascular events. Thromboembolic events typically occur within 24 hours of the ablation procedure, with the high-risk period extending for the first 2 weeks following ablation. 798,1204 In one series that surveyed 26 embolic stroke events that occurred in a series of 3060 patients, long-term neurological outcomes were as follows: severe impairment (3 patients, with 2 possibly related deaths); moderate impairment (10 patients); mild impairment (9 patients); and unknown (4 patients). 1202 A number of potential explanations for the development of thromboembolic complications have been proposed. These include the development of thrombi on or within stationary sheaths or ablation catheters positioned within the LA, char formation at the tip of the ablation catheter and at the site of ablation, disruption of a thrombus located in the atrium prior to the ablation procedure, and electrical cardioversion during procedures. 875 Incidence of these events can be reduced by a combination of detailed preprocedural imaging, a strict anticoagulation protocol, meticulous attention to sheath management, and careful control of RF energy to minimize the risk of char formation. Of the writing group members, 68% report maintaining a constant heparinized flush through all long sheaths with access to the LA, and most heparinize to an ACT >300 seconds before transseptal catheterization. Diagnosis of a symptomatic thromboembolic event is usually straightforward when ischemia or infarction results from arterial occlusion interrupting perfusion of dependent tissue. The potential manifestations depend on where the occlusion occurs, whether it be intracranial, coronary arterial, abdominal, or in other peripheral arterial beds. We have previously discussed the prevention of thromboembolism by intraprocedural and postprocedural anticoagulation in Section 7: Technical Aspects of Ablation to Maximize Safety and Anticoagulation. Treatment of a thromboembolic event will vary according to the location of the embolus. Peripheral arterial embolization might be amenable to surgical thrombectomy, whereas cerebral embolization has traditionally been managed conservatively and the consequences accepted. There is growing interest, however, in aggressive early management of such events, using either thrombolytic drugs or percutaneous interventional techniques. Some delay in diagnosis of a thromboembolic event that occurs during an ablation procedure while a patient is under general anesthesia cannot be avoided. Asymptomatic Cerebral Emboli ACE is defined as an occlusion of a blood vessel in the brain due to an embolus that does not result in any acute clinical symptoms and is therefore “silent.” 800,1205 Emboli can result from a thrombus, air, gas, tissue, or fat. During an AF ablation procedure, potential sources of these microemboli include thrombi, which can develop on intracardiac catheters; sheath materials; air introduction through a sheath during catheter insertion or exchanges; dislodgement of thrombi in the heart; or as a result of thrombi or gas that forms during the ablation process. Diffusion-weighted MRI (DW-MRI), with or without fluid-attenuated inversion recovery (FLAIR) imaging, is very sensitive for identifying acute ischemic injury and can detect a cerebral lesion created by an embolus as early as 30 minutes postablation. The first report of ACE lesions following AF ablation was published in 2006. 1206 In this report, 2 of 20 patients developed new asymptomatic cerebral lesions on MRI, following AF ablation. Subsequent to this report, multiple studies have reported that DW-MRI can detect new acute lesions created by emboli, following up to 50% of AF ablation procedures. 723,724,800,1205,1207,1208,1209 The incidence of this complication initially appeared to vary according to the system used for ablation, and was reported to be highest with the use of nonirrigated circumferential multielectrode ablation catheters with duty cycled phased RF energy. 1209,1210 Based on these findings, modifications were made in anticoagulation, sheath management, and energy delivery protocols. Following introduction of these modifications, two subsequent studies reported a 2% or lower incidence of ACE lesions with use of this same circular phased RF ablation catheter. 728,731,1211 One study examined the important question concerning whether these lesions persist on repeat DW-MRI and T2 FLAIR scanning. In this study, 14 patients who had 50 new silent cerebral emboli detected post-AF ablation had a repeat MRI a median of 3 months later. It was notable that 47 of the 50 lesions (94%) resolved in the interim. The three lesions in three patients that produced a residual defect at repeat scanning were initially >10 mm in size, and one of these patients had neurological symptoms. When considering the significance of the ACE lesions that have been observed following AF ablation, it is important to note that cerebral embolism has also been observed after most types of cardiac invasive procedures, including coronary angiography, carotid artery stenting, and cardiac valve replacement. 1212,1213 Importantly, as of now, a direct link between silent cerebral embolism and a decline in neurocognitive function has not been proven. 800,1205,1211,1212 However, one study has reported mild postoperative neurocognitive dysfunction in 13% of patients undergoing ablation for PAF and in 20% undergoing ablation for persistent AF. The precise mechanism of this neurocognitive dysfunction and its possible link to ACE lesions needs to be explored further. 1214 A decade after the first description of ACE lesions following AF ablation, a tremendous amount of new knowledge has been generated concerning this important complication of AF ablation. 800,1205,1211,1215,1216 These efforts have resulted in a striking decrease in the incidence of this complication. During this period of time, studies have identified a number of techniques to lower the risk of ACE lesions, including (1) aggressive anticoagulation prior to, during, and following ablation; (2) careful sheath management; (3) modifications in the delivery of phased RF energy; and (4) choice of ablation energy source and lesion sets. The long-term prognostic implications of ACE following AF ablation remain unclear. Because multiple studies have reported that the majority of acute lesions regress without evidence of chronic glial scar when reassessed several weeks to months later, the occurrence of long-term sequelae appears unlikely. 1205 Nevertheless, there is a possibility of long-term sequelae, given the association between silent cerebral infarcts and an increased long-term risk of dementia. 1217 While further work remains, the amount of progress is striking and will benefit our patients in the long term. Air Embolism The most common cause of air embolism is introduction of air via the transseptal sheath. Although this can be introduced through the infusion line, it can also occur with suction when catheters are removed. Air embolism has been reported with coronary angiography, percutaneous interventions requiring access to the LA, and during ablation procedures. 803,1218,1219,1220,1221 Air embolism to the cerebral vasculature can be associated with altered mental status, seizure, and focal neurological signs. Central nervous system dysfunction is attributable to both mechanical obstruction of the arterioles and thrombotic-inflammatory responses of air-injured epithelium. 1219,1220 Although immediate diagnosis and treatment is based on clinical suspicion, prompt MRI or CT scans obtained before the intravascular air is absorbed might show multiple serpiginous hypodensities representing air in the cerebral vasculature, with or without acute infarction. 803,1221 Most importantly, AEF should be ruled out if air embolism is documented after the ablation. A common presentation of air embolism during AF ablation is acute inferior ischemia and/or heart block. This reflects the preferential downstream migration of air emboli into the right coronary artery (RCA). The preferential manifestation of air emboli into the RCA territory might reflect the superior position of the RCA ostium in the supine patient. Supportive care usually results in complete resolution of symptoms and signs within minutes. However, pacing and cardiopulmonary resuscitation might be needed if the hypotension and AV block persist. A recent study reported the clinical characteristics and outcomes of 5 out of a series of 2976 patients who underwent AF ablation who experienced a massive air embolism during the procedure. Hemodynamic collapse and hypoxemia occurred in all the patients and persisted for 10–35 minutes. Despite this, all the patients had complete recovery. 1221 it is imperative, however, that all infusion lines be monitored closely for bubbles. Whenever catheters are removed, they should be withdrawn slowly to minimize suction effects, and the fluid column within the sheath should be aspirated simultaneously. Particular care is advised when inserting and removing balloon catheters through large sheaths. 1222 Treatment should be initiated immediately in the laboratory if cerebral air embolism is suspected. The most important initial step is to maximize cerebral perfusion by the administration of fluids and supplemental oxygen, which increases the rate of nitrogen absorption from air bubbles. For large air emboli, it might be beneficial to briefly suspend the patient in a head-down position. 1218,1219 Treatment with hyperbaric oxygen can reverse the condition and minimize endothelial thromboinflammatory injury if it is started within a few hours. 1220 Heparin appears to limit injury in animal models of cerebral arterial air embolism. 1223 Vascular Complications Vascular complications, including groin hematoma, retroperitoneal bleed, femoral artery pseudoaneurysm, or arteriove-nous fistula, are the most common complications of AF ablation. The incidence of the more significant of these complications (femoral pseudoaneurysm, arteriovenous fistula, and retroperitoneal bleeding) varies from 0.2% to 1.5%. 806,808,920,921,1224,1225,1226 The first and updated worldwide surveys of AF ablation in 2005 and 2010, respectively, reported that the incidence of vascular complications was 0.95% (84 of 8745 patients) and 1.5% (240 of 16309 patients), respectively. 806,920 A report from the United States analyzing an estimated 93,801 AF ablations between 2000 and 2010 showed the overall incidence of vascular complications requiring blood transfusion or surgical repair was 1.53%, which remained statistically unchanged from year 2000 to 2010. 921 More recent reports from Czechia, Belgium, Japan, and the United States reported the incidence of these complications as 1.1% (13 of 1192 procedures in 959 patients), 1.2% (15 of 1233 procedures in 947 patients), 0.2% (7 of 3373 patients), and 1.5% (18 of 1190 patients), respectively. 808,1224,1225,1226 The incidence of vascular complications that result from AF ablation is lower than those reported for ventricular tachycardia ablation (range, 3.6%–6.9%), in which femoral arterial access is used in many cases. 1227,1228 Most groin hematomas can be managed conservatively or with ultrasound-guided compression. However, complications such as femoral pseudoaneurysm, arteriovenous fistula, and retroperitoneal bleeding might require blood transfusion and/or surgical or percutaneous repair, which leads to increased morbidity and prolonged hospital stay. 1229 Rarely, a large dense hematoma can lead to femoral neurological sequelae. The incidence of these complications can be related to the number and size of the venous sheaths used, insertion of an arterial pressure line, and perhaps to the intense anticoagulation management before, during, and after the procedure. Recent studies have suggested uninterrupted warfarin as an optimal anticoagulation regimen because it reduces stroke and nonmajor bleeding complications compared with interrupted warfarin with heparin bridging. 834 Further, uninterrupted or briefly interrupted use of a direct oral anticoagulant was shown to be as safe and effective as uninterrupted warfarin. 840,842,1230 The results of the RE-CIRCUIT study were recently published, which was a head-to-head comparison of performing AF ablation on patients receiving uninterrupted dabigatran vs uninterrupted warfarin. 841 This study randomized 704 patients across 104 sites to these two anticoagulation strategies. The incidence of major bleeding events during and up to 8 weeks postablation among the 635 patients who underwent AF ablation was significantly lower with dabigatran than with warfarin (5 patients [1.6%] vs 22 patients [6.9%]); absolute RD -5.3%, RR reduction 77%). There has been one other smaller head-to-head comparison published of uninterrupted rivaroxaban vs uninterrupted warfarin (Venture-AF, N = 248). 842 This study reported one major bleeding event, one ischemic stroke, and one vascular death, each of which occurred in the warfarin arm of the study. The approach used for femoral venous access can impact on the risk of vascular complications. When an inferior approach to femoral vein access is used, small medial branches of the femoral artery, which can run across and superficial to the femoral vein, might be penetrated before entry to the femoral vein, possibly leading to a femoral pseudoa-neurysm and arteriovenous fistula. When a superior approach is used, there is an increased risk of retroperitoneal bleeding. To prevent these vascular complications, real-time ultrasound-guided venipuncture is useful and can be recommended because it reduces both major and minor vascular complications in patients undergoing AF ablation and/or electrophysiological procedures. 1231,1232 Among the writing group members, two-thirds routinely use ultrasound imaging to guide vascular access. Acute Coronary Artery Occlusion and Stenosis Injury to the coronary arteries during AF ablation is rare. In a consecutive series of 5709 patients undergoing ablation of AF, coronary arterial injury was observed to occur in eight patients (0.14%). 1233 The circumflex artery is in close proximity to the lateral LA and can potentially be injured during ablation at sites adjacent to its course within the CS, the lateral mitral isthmus, or the base of the LAA. Occlusion of the circumflex accounted for three of the eight cases in the above series, all presenting with ventricular fibrillation 20 and 60 minutes after mitral isthmus ablation and 6 hours after ablation at the LAA base, respectively. 1233 Others have also described features of acute myocardial infarction with ST segment changes occurring during ablation at the mitral isthmus. 923 These patients have variably undergone unsuccessful intracoronary vasodilators or thrombectomy and have had to progress to coronary stenting. A single case presenting 48 hours after mitral isthmus ablation with total circumflex occlusion and ventricular arrhythmia storm is described as having ongoing ventricular arrhythmia requiring ablation and defibrillator implantation, highlighting the potential for ongoing consequences as a result of coronary artery injury. 1234 The sinus node artery originates from the proximal circumflex artery in one-third of cases and then courses along the anterior LA and then the septal SVC, and could therefore be susceptible to injury during ablation. In the above series, five of the eight patients presented with acute sinus node dysfunction. 1233 In most of these cases, the culprit site was adjacent to the sinus node artery (per CT) at the anterior LA or septal RA. All these cases presented with sinus arrest during or within 1 hour of ablation and with no evidence of any other electrocardiographic changes associated with coronary occlusion. Two of these patients eventually required permanent pacemaker insertion with significant atrial pacing during follow-up. Others have described a more transient sinus node dysfunction due to occlusion of the sinus node artery. 1235 The cavotricuspid isthmus can be ablated in conjunction with AF ablation. This region is in close proximity to the RCA, and injury to this vessel has been described. 1236,1237 These have occurred both acutely and later during the case, and with both septal and lateral approaches to the ablation. In addition to the direct injury and occlusion at the sites of ablation, a single case of thromboembolic occlusion of the left anterior descending artery the day after ablation has been described. 1238 This case was known to have factor V Leiden mutation, was therapeutically anticoagulated with an INR of 2, and the activated clotting time had been maintained between 280 and 390 seconds. Angiography demonstrated thrombus in the left anterior descending artery, requiring intervention. This case highlights the need for meticulous anticoagulation, sheath management, and physician awareness of the potential for thromboembolism to present as coronary occlusion. Although presentation with acute coronary artery occlusion is low, the possibility of thermal injury without occlusion and the possibility of subsequent remodeling leading to stenosis of a coronary artery should be considered. The most vulnerable location for this would appear to be the circumflex vessel during ablation of the mitral isthmus. In a series of 54 patients who had undergone mitral isthmus ablation, coronary angiography was performed before and after ablation. 1239 Fifteen patients (28%) had angiographic changes following ablation, eight with midcircumflex narrowing, one with circumflex and obtuse marginal narrowing, one with obtuse marginal narrowing only, and five with distal circumflex narrowing or occlusion. A further five had significant narrowing that resolved with intracoronary vasodilators. Patients with such coronary arterial changes had a significantly longer ablation time within the CS. Therefore, limiting excessive ablation, particularly in areas adjacent to the coronary vasculature, should be a consideration in planning the ablation strategy. In the intraoperative setting, late coronary stenosis has been described at sites of previous ablation. 1240 There can be several determining factors in the development of coronary artery injury during AF ablation. These include the degree of protective epicardial adiposity, coronary blood flow, and the intensity and duration of ablation; however, the most predictable is that of the location of ablation adjacent to the course of the coronary artery. Careful monitoring and avoiding high-power energy delivery in the vicinity of these vessels are potentially important in minimizing the risk of arterial injury. Radiation Exposure During Catheter Ablation of AF An important, less easily recognized, and rarely considered potential complication of AF ablation is the delayed effect of the radiation received by the patients, including acute and subacute skin injury, malignancy, and genetic abnormalities. 1,1241,1242,1243,1244,1245,1246,1247 Fluoroscopy is required for most components of the procedure, including catheter placement, positioning a multielectrode catheter into the CS, double transseptal catheterization, PV angiography, and LA ablation. A survey of the writing group members reveals that two-thirds use single-plane fluoroscopy, whereas one-third employ biplane. One study reported a mean fluoroscopy time >60 minutes, with corresponding higher effective radiation doses in obese patients. 1244,1246 By using a vest containing 50–60 dosimeters to measure peak skin doses (PSDs), another study reported a mean PSD of 1.0 ± 0.5 Gy in the right anterior oblique and 1.5 ± 0.4 Gy in the left anterior oblique projection, during a mean fluoroscopy time of 67.8 ± 21 minutes. 1245 They estimated an overall lifetime risk of excess fatal malignancies normalized to 60 minutes of fluoroscopy of 0.07% for women and of 0.1% for men. 1245 The relatively low radiation exposure to the patients in this study despite the prolonged fluoroscopy durations was attributable to the state-of-the-art very low pulsed fluoroscopy frame rate, the avoidance of magnification, and the optimal adjustments of fluoroscopy exposure rates. The resulting lifetime risk of malignancy was thus within the range previously reported for ablation of supraventricular tachycardias. However, this study demonstrated that catheter ablation of AF required significantly greater fluoros-copy duration and radiation exposure than simpler catheter ablation procedures. Thus, and especially because AF ablation procedures often need to be repeated, electro-physiologists should make every attempt to minimize radiation exposure. Increasing availability and familiarity of electrophysiologists with 3D mapping systems, as well as the availability of CF monitoring, have significantly reduced fluoroscopy time and the need for fluoroscopy in recent years. 747,1186,1248,1249 This can only be achieved, however, by an awareness of the importance of reducing fluoroscopy time, and therefore radiation exposure, by the operator. 1250 It has been shown that use of optimized conventional fluoroscopy and optimized use of 3D mapping can result in a marked reduction in radiation exposure. 1251 It is also important to recognize that fluoros-copy time is only weakly linked to true radiation exposure, because it does not reflect the fluoroscopy equipment being used, nor patient-specific factors such as obesity. The use of remote navigation for PVI appears to be effective, with fewer periprocedural complications and significant reductions in fluoroscopy exposure for both patient and operator. 749,1252,1253 Another interesting option to minimize radiation exposure to the operator and to alleviate the orthopedic implications of conventional lead aprons is the use of a radioprotection cabin or a suspended lead apron. 1254 More recently, it has been shown that PVI is feasible without using fluoroscopy or with extremely limited fluoroscopy. To safely navigate catheters in the heart with no fluoroscopy, intracardiac ultrasound is mandatory, as well as imaging integration with preacquired CT or MRI. 763,1255,1256 Pericarditis More than 50% of the patients who undergo catheter ablation of AF note some pleuritic chest pain in the first several days following their procedure. It is also common to observe a “trace” pericardial effusion following AF ablation. These largely self-limited manifestations of AF ablation-induced pericarditis are so common and of so little consequence that they are considered as part of the standard clinical course for patients who undergo AF ablation rather than as a complication of the procedure. A small subset of these patients will go on to develop more severe and clinically significant manifestations of pericarditis. In two recent multicenter registries, pericarditis has been reported to occur in 0.1% and 0.6% of patients, respectively. 1059,1257 When transmural lesions are generated during catheter ablation of AF, some epicardial inflammation, and therefore some pericarditis, is inevitable. However, more extensive pericarditis can complicate AF ablation procedures both acutely and at some delay. These presentations include Dressler syndrome, pericarditis leading to delayed cardiac tamponade, and constrictive pericarditis. 1258,1259,1260 These severe manifestations and consequences of pericarditis presented between 18 days and 3 months after their ablation procedures. The standard international practice for a short hospital stay after AF ablation procedures can contribute to an underappreciation of early postablation pericarditis. There is currently no evidence to support the use of nonsteroidal anti-inflammatory drugs (NSAIDs) or steroids to prevent AF recurrences. A single bolus injection of low-dose hydrocortisone (100 mg) reduced the incidence of peri-carditis from 2.5% to 1.1% in one recent series from Japan, but no difference in early or late recurrences was found after AF ablation. 1261 Another Japanese study also failed to demonstrate a reduction in immediate, early, or midterm AF recurrence with either a low-dose (hydrocortisone 100 mg) or moderate-dose (methylprednisolone 125 mg) single steroid bolus. Colchicine is currently the cornerstone of pericarditis treatment that occurs outside of the AF ablation setting, although specific data after AF ablation are lacking. In one trial, however, in which patients were randomized to a 3-month course of colchicine (0.5 mg twice daily) or placebo, early recurrence was significantly reduced (33.5% of placebo patients vs 16% for colchicine), and this was strongly associated with a reduction in inflammatory mediators such as IL-6 and C-reactive protein. After a 15-month follow-up, a 37% reduction in the RR of AF recurrence was observed (number needed to treat = 6). 985 In a subsequent randomized study of 233 patients with PAF, these investigators reported that the long-term recurrence rate was 31% among the patients treated with colchicine vs 49% among the placebo patients. Colchicine also resulted in an improvement in QOL. 986 Mitral Valve Trauma and Curvilinear Catheter Entrapment Entrapment of a circular multielectrode mapping catheter by the mitral valve apparatus is an uncommon but established complication of AF ablation. 1262,1263,1264,1265,1266,1267,1268,1396 It results from inadvertent positioning of a circular electrode catheter close to the mitral valve or into the left ventricle, often during attempts to position the catheter into the LIPV or when using such catheters to create electroanatomical maps of the LA. This complication should be suspected when attempts to reposition the catheter into another PV are met with resistance. When suspected, it is important to confirm the diagnosis with echocardiography. Although successful freeing of the catheter has been reported with gentle clockwise catheter manipulation and advancing the sheath into the ventricle in two patients, there have also been a number of cases reported in which the mitral valve apparatus and/or papillary muscles are torn during attempts to free the catheter. 1263,1264,1268,1269,1396 There have also been several cases reported in which the distal tip of the circular catheter broke off during attempts at catheter removal and had to be subsequently removed either with a snare or with an open surgical procedure. 1263,1265,1266 We recommend that if gentle attempts to free the catheter fail, elective surgical removal of the catheter should be performed. It is important for all electrophysiologists who perform AF ablation to be aware of this potentially serious complication. Every effort should be made to be certain that the circular catheter is kept safely away from the mitral valve and that only clockwise torque be applied to the catheter, with particular care taken when approaching the LIPV. The incidence of this rare complication is unknown, but might have decreased in recent years due to improved awareness. Limited data are available regarding outcomes of AF ablation in patients with prosthetic valves. One small, matched cohort study suggested that long-term outcomes might be similar, but ablation procedures were longer and were associated with a numerically higher rate of complications in patients with prior mitral or aortic valve replacement (AVR). 908 The development of new perivalvular leak following AF ablation in a patient with a mitral prosthesis has been reported, suggesting that care should be taken when ablating near the annulus in such patients. 921 Mortality Risk with AF Ablation Although AF ablation is generally considered to be safe, devastating complications can occur rarely, some being fatal. In a recent survey, death was reported in 32 of 32,569 (or 1 in 1017) patients undergoing AF ablation procedures worldwide. 1039 The most frequent cause of death was cardiac tamponade, accounting for 25% of the deaths, of which 3% occurred later than 30 days after the procedure. Stroke was responsible in 16% of the cases, of which 6% occurred later than 30 days. AEF also accounted for 16% of the deaths, with extensive pneumonia responsible for 6%. Less common causes of death observed in the periprocedural phase included myocardial infarction, irreversible torsades de pointes, septicemia, sudden respiratory arrest, extrapericar-dial PV perforation, occlusion of both lateral PVs, hemo-thorax, and anaphylaxis, which were each responsible for 3% of early deaths. Twenty-two percent of all deaths occurred more than 30 days after the procedure. Among the identified causes of late death were asphyxia from tracheal compression secondary to subclavian hematoma, intracranial bleeding, acute respiratory distress syndrome, and esophageal perforation by the intraoperative TEE probe, with each cause contributing to 3% of all late deaths. It should be noted that these reported mortality risks of AF ablation came mostly from experienced operators and centers. In the community setting, the mortality risk of AF ablation can be much higher. Indeed, one study of 93,801 patients undergoing AF ablation in the United States between 2000 and 2010 showed that one in 238 AF ablation patients were never discharged alive following their procedure. These mortality risks were due primarily to inexperienced operators who performed fewer than 25 procedures annually, and to low-volume hospitals that performed fewer than 50 procedures annually. 921 When a 30-day all-cause mortality Definition is used for AF ablation, AF ablation mortality rises to 1 in 125 patients within the Medicare population (mean age of 72). 921 Awareness about the risk of death and the possible causes might help physicians set more appropriate and efficient standards for procedural safety, and need to be considered in the patient’s decision-making process. Stiff Left Atrial Syndrome First described after mitral valve surgery in 1988, stiff LA syndrome was recognized as a rare complication of LA catheter ablation in 2011. 1110,1111,1270,1271,1272,1273 One early report described a series of three patients with unexplained exertional dyspnea, LA hypertension, and large V waves on LA pressure or pulmonary capillary wedge pressure (PCWP) tracings after multiple surgical LA ablation procedures. 1271 A subsequent study prospectively collected 1380 consecutive patients undergoing ablation, obtaining echocardiograms before and after ablation to assess for pulmonary hypertension. 1272 Excluding patients with PV stenosis or significant mitral valve disease, there were 19 patients (1.4%) with new or worsening pulmonary hypertension, LA diastolic abnormalities, and clinical findings of dyspnea, HF, pulmonary hypertension (mean PA pressure ≥25 mm Hg or during exercise ≥30 mm Hg), and large V waves (≥10 mm Hg and higher than mean LA pressure tracings) on PCWP or LA pressure tracings. Other authors reported worsened pulmonary hypertension (echocardiographic right ventricular systolic pressure (RVSP) .35 mm Hg with increases of >10 mm Hg) in 41 of 499 patients (8.2%) by 3 months after ablation. 1110 These studies were flawed, however, by the low cutoff for diagnosing PA hypertension, particularly after an ablation with excess volume delivery. Stiff LA syndrome was also reported in 9 patients after surgical maze procedures, presenting with unexplained dyspnea, severe pulmonary and LA hypertension, giant LA V waves, absent LA or LV A waves, blunted X descents, and elevated left ventricular end-diastolic pressure attributed to abnormal LA compliance and contractility. 1274 Studies have identified small LA size (≤45 mm), high mean LA pressure, severe LA scarring (>60%), diabetes mellitus (DM), and OSA as independent predictors of pulmonary hypertension or stiff LA syndrome postablation. 1272 The potential importance of scar burden and the extent of RF ablation to LA stiffness or function has also been noted by other investigators. In another study of 26 patients with mean follow-up of 80 months, LA scar by MRI was related to the number of procedures, total RF duration, LAA EF, and expansion index. 1275 LAA EF correlated with exercise capacity at follow-up, and LA scar extent had a negative correlation with exercise capacity. Another study reported that LA stiffness index, derived from invasive pressure measurements and cardiac MRI volumes during sinus rhythm (ΔP/ΔV) was higher in patients with persistent rather than PAF, older age, and prior LA ablation. 1276 A subsequent study reported that in 70 patients with 12-month follow-up, LV diastolic dysfunction worsened in 27% and correlated with total ablation time, concluding that more aggressive ablation might aggravate diastolic dysfunction. 1145 The stiff LA syndrome fortunately appears to be largely responsive to diuretic therapy. One study reported that all 19 of their patients had symptomatic improvement after diuretic therapy, noting that diuretics appeared more effective for this syndrome than for other forms of pulmonary hypertension. 1272 In contrast, another study reported a case of stiff LA syndrome after two AF catheter ablation procedures that failed with furosemide and spironolactone, but which responded to sildenafil. 927 In summary, stiff LA syndrome or worsened pulmonary hypertension appears to occur in 1.4%–8% of patients after AF RF catheter ablation. The diagnosis of stiff LA syndrome after AF or LA ablation should be sought for patients who present with unexplained dyspnea with signs of right HF. Diagnosis can be made by signs of right HF in the presence of preserved left ventricular function, pulmonary hypertension (mean PA pressure ≥25 mm Hg or during exercise ≥30 mm Hg), and large V waves (≥20 mm Hg and higher than mean LA pressure tracings) on PCWP or LA pressure tracings in the absence of significant mitral valve disease or PV stenosis. We also recommend that to reduce the risk of stiff LA syndrome, judicious use of extensive LA ablation be considered in patients with small LA size, high LA pressures, preexisting severe LA scarring, DM, or OSA. Patients with stiff LA syndrome usually respond well to diuretics. Cough Cough is a specific respiratory symptom that can occur after catheter ablation of AF. It might be a sign of underlying PV stenosis, PN injury, direct bronchial injury, stiff LA syndrome, gastroesophageal reflux, pulmonary embolism, pericarditis, or other iatrogenic respiratory complications such as ventilator-associated pneumonia or postprocedure aspiration pneumonia. Although there is a paucity of data on the incidence and mechanisms of postprocedure cough, the underlying mechanisms can vary according to the ablation technology. After RF ablation, cough might point to the presence of RF-induced PV stenosis. Whereas mild PV stenosis is frequently asymptomatic, patients with more extensive and severe PV narrowing can present with cough, dyspnea, chest pain, or hemoptysis. 1152,1200 Similarly, another study reported that in 18 patients with severe PV stenosis, 7 (39%) reported cough. 462 Cough might also be a sign of RF-induced PN injury. Although a rare complication (0.48%), RF-induced PN injury is frequently (9 of 22 patients) associated with immediate features of dyspnea, cough, hiccup, and/or sudden diaphragmatic elevation. 1277 Cough following CBA is more frequent. In fact, as many as 1 in 6 patients can develop a dry cough following CBA, which is usually self-limiting in 91%. 1278 Whereas the most evident mechanism for postprocedure cough is that of CBA-induced PN injury (up to 11%), some reports suggest that the cough is caused by direct upper airway irritation during CBA (bronchial or pulmonary injury). 1278 In an experimental model, Aryana et al showed that CBA can elicit direct and acute bronchial inflammation, bleeding, and mucosal injury. 1277 A recent study reported ice formation within the left main-stem bronchus using real-time bronchoscopy during CBA. 583,584 Given the increasing number of case reports detailing respiratory complaints after CBA, a systematic examination of the short- and long-term consequences of CBA on normal bronchial tissue during PVI is warranted. Increase in Heart Rate and/or Sinus Tachycardia A subset of patients will experience a significant increase in their resting sinus heart rate following AF ablation. 110 Although this typically results in a 10–20 beats per minute (bpm) increase in heart rate (well below the 100 bpm threshold to classify the increase as sinus tachycardia), the resulting increase in heart rate can exceed 100 bpm in a very small subset of patients. This phenomenon is related to shifts in autonomic tone following ablation and is predictive of ablation success. This shift in autonomic tone results from ablation of GP that are commonly located near the PV antra, as previously discussed. 110,121 Stimulation of GP has been shown to elicit AF by producing repetitive bursts of rapid focal PV firing, and ablation of GP can play a role in AF treatment. 257,577,1279 Following ablation of GPs, signs of parasympathetic withdrawal such as increased heart rate and attenuated heart rate variability can be observed, and these signs have been associated with improved procedural outcomes. 118,126,577,1280,1281 Although the increase in heart rate and reduction in heart rate variability after ablation typically follow a transient time course, with resolution within 3 months, some studies have shown that the long-term persistence of these autonomic changes is associated with improved clinical outcomes. 126 These clinical data are consistent with experimental findings demonstrating a reduction in stellate ganglion nerve activity and subsequent AF with continuous low-level vagal nerve stimulation. 1200 Thus, the observation of increased heart rate following ablation can be a normal finding with potential positive prognostic implications regarding outcomes and is not necessarily a procedural complication per se. Section 11: Training Requirements Overview The strategies, specific methods, and technology pertaining to AF ablation are evolving. Accordingly, the guidelines for training to perform this procedure must be flexible in recognition of various approaches and technologies that will change with advances in the field. Training for AF ablation should encompass six fundamental principles: (1) appropriate selection of patients; (2) knowledge of the anatomy of the atria and adjacent structures; (3) conceptual knowledge of strategies to ablate AF; (4) technical competence; (5) recognition, prevention, and management of complications; and (6) appropriate follow-up and long-term management. The training required in each of these areas differs from other ablation procedures because, in comparison, ablation of AF is technically more difficult, is associated with greater risks, and requires more careful follow-up. Appropriate Selection of Patients Trainees should recognize clinical attributes that can increase the difficulty of a transseptal puncture, increase the risk of the procedure, and affect short- and long-term outcomes. These factors are discussed in Sections 8 and 9 of this document. The trainee should also develop the judgment to decide whether conscious sedation or general anesthesia would be most appropriate for the case under consideration. It is also important to assess the severity of symptoms related to AF and the potential benefit of an ablation procedure. Trainees should be experienced in counseling patients about the potential risks and benefits of, as well as the alternatives to, an ablation procedure and should be able to apply this knowledge for recommendations specific to the needs of individual patients. They should also take into consideration the prior use of AADs and pharmacological alternatives to AF ablation. It is also important for electrophysiologists involved with catheter ablation to be knowledgeable about surgical ablation techniques for AF. In particular, electrophysiologists who perform AF ablation procedures must be aware of the indications, techniques, and outcomes of surgical approaches for AF ablation. This applies both to the new minimally invasive surgical approaches, AF surgery combined with other cardiac surgical procedures, and the Cox-Maze III procedure (see Section 12). Anatomy of the Atria and Adjacent Structures Detailed knowledge about the anatomy of the LA and its adjacent structures is crucial for performing the technical aspects of transseptal puncture and cannulation, LA mapping, and isolation of the PVs or modification of the substrate that sustains AF. The trainee must recognize the anatomic relationship of the atria, SVC, and PVs to the pulmonary arteries, aorta, mitral annulus, PNs, sympathetic and parasympathetic innervation, esophagus, and other mediastinal structures (Figure 1). These anatomic relationships affect the ability to perform the procedure successfully and to avoid complications. Conceptual Knowledge of Strategies to Ablate AF Trainees should understand the pathophysiology of AF and its implications for strategies to ablate AF. This includes the role of the PVs, the SVC, the musculature of the LA, and the potential impact of autonomic stimulation. They should understand the rationale for isolation of the PVs and elimination of the foci that trigger AF, as well as the basis for broad circumferential ablation of tissue or elimination of fractionated potentials or other technologies that appear to alter the substrate that sustains AF. Technical Competence The technical skills needed for ablation of AF are substantial. These include anticoagulation management, transseptal needle puncture and cannulation of the LA, precise manipulation of the catheter for mapping and ablation, identification of the pulmonary ostia, adjustment of the energy used for ablation, and the appropriate use of fluoroscopy, radiographic contrast for imaging, 3D mapping systems and/or ICE. Simulation technologies are evolving that could help trainees gain experience with fundamental techniques in the early phase of learning procedural skills or the recognition and management of acute complications such as cardiac tamponade. 1250,1282,1283 There are substantial differences among laboratories in the use of radiographic contrast imaging, EAM or echocardiography, and the number and types of catheters used to identify electrical endpoints and to perform ablation. The degree of expertise gained in the use of a specific technology will depend on where training is completed, as well as the duration of training. Nonetheless, trainees should be expected to understand the potential advantages and limitations of these systems and should have the ability to interpret basic images and electrical recordings obtained from these various methodologies. They should be well versed in the principles of radiation safety for patients and the medical personnel who perform ablation procedures. Training programs should emphasize the interpretation of intracardiac electrograms for recognition of PV potentials and determination of when electrical isolation of a PV has been achieved, the role of CS and LAA pacing in the differentiation of far field electrograms from PV potentials, identification of fractionated low-amplitude LA potentials, and techniques required to map and ablate right and/or LA tachycardias or AFL. Concepts related to entrainment are especially important. Trainees need to be skilled in identifying the presence, mechanism, origin, and ablation of other supra-ventricular tachycardias that could act as triggering mechanisms for AF, such as AV nodal reentrant tachycardia and AV reentrant tachycardia. Training and competence in RF catheter ablation are essential because this ablation technology is needed for ablation of typical and atypical AFL. Many electrophysiology laboratories also use RF energy as the preferred energy source for ablation of AF. Many other electrophysiologists prefer CBA for their AF ablation procedures. Other ablation technologies that are currently available in some parts of the world include laser balloon ablation and ablation using circular multielectrode RF ablation catheters. Trainees should be familiar with the advantages and limitations of each energy source and associated delivery system. Procedural Experience The 2015 American College of Cardiology/American Heart Association/Heart Rhythm Society Advanced Training Statement on Clinical Cardiac Electrophysiology proposed a minimum of 5 five focal ATs, 30 macroreentrant ATs (including 20 isthmus- and 10 nonisthmus-dependent/complex macro-reentry) and 50 AF ablation procedures for those who undergo fellowships in clinical cardiac electrophysiology. 1284 The writing group members are supportive of the requirement that trainees perform at least 50 AF ablation procedures and at least 30 macroreentrant ATs (including 20 isthmus-and 10 nonisthmus-dependent/complex macroreentry) during fellowship training. Furthermore, the writing group recommends that those performing the procedure perform at least several AF ablation procedures per month to maintain competence. These numbers underestimate the experience required for a high degree of proficiency. 991,992,1082,1285,1286 Exact numerical values are difficult to specify because technical skills develop at different rates. Nonetheless, comparisons of high- and low-volume centers suggest that outcomes are better at centers that have performed more than 100 procedures. 806 Other data report improved outcomes for operators with an annual procedure volume of at least 25 cases and for centers with an annual procedure volume of at least 50 cases. 921 Moreover, the selection of patients and interpretation of AFL and other ATs that are often observed in patients with AF require training that is unique to electrophysiology fellowships. Trainees who intend to perform AF ablation independently should receive additional training after the standard fellowship is completed if they performed fewer than 50 AF ablation procedures during training. Recognition, Prevention, and Management of Complications As previously discussed, ablation of AF is associated with substantial risks that must be recognized. Training programs must emphasize techniques that reduce these risks. This includes careful manipulation of catheters, appropriate use of anticoagulation, modification of energy delivered on the posterior wall of the LA, and the risk of applying energy within the PVs or LAA. Fellows should be trained to suspect cardiac tamponade or internal bleeding as a common cause of hypotension. Training should also include management of these complications. The skills to perform an emergent echocardiogram when cardiac tamponade is suspected are important. It is preferable for fellows to undergo training in pericardiocente-sis. If trainees do not gain proficiency in pericardiocentesis, they must be able to recognize and diagnose cardiac tamponade and have immediate access to a physician who can perform an emergency pericardiocentesis. They should understand the risks of conscious sedation, which include hypoven-tilation, aspiration, and respiratory arrest. They should also recognize the delayed time course associated with the development of AEFs or PV stenosis, as well as the appropriate steps needed to diagnose and manage these complications. Appropriate Follow-up and Long-Term Management Management of patients after hospital discharge can be complex and requires commitment from the physician (cardiolo-gist or internist) who will be following the patient on an ongoing basis. Individuals undergoing training in AF ablation should participate in a longitudinal clinic in which these patients are followed. Experience must be gained in diagnosis and management of postprocedure complications, including esophageal injury, PV stenosis, and late tamponade, pseudoa-neurysm, or arteriovenous fistula. Because the prevalence of some of these complications is very low, it is possible that the trainee will not have first-hand experience with patients. Therefore, supplementation of clinical experience with didactic presentations on diagnosis and management of postablation complications is required. Prophylaxis against and management of postprocedure atrial arrhythmias, including timing of repeat ablation and use of concomitant AADs, must be taught to trainees. Finally, the training experience must address the risk-benefit decision-making regarding the use of intermediate and long-term anticoagulation therapy. Given the complexity of these issues, it would be ill-advised for cardiologists who are not trained in electrophysiology to consider performing ablation procedures for AF. Due to these issues and prerequisites for obtaining and maintaining competency, this statement should also extend to the performance of cryoabla-tion or other balloon ablation. Section 12: Surgical and Hybrid AF Ablation Historical Considerations and Development of the Cox-Maze Procedure There is a rich history of surgery for AF. Initial procedures were aimed at controlling the ventricular response rate. Later procedures were directed at converting AF to a normal sinus rhythm. Following experimental investigation, the Maze procedure was introduced for the surgical treatment of AF in 1987 by James Cox. This procedure was designed to interrupt macroreentrant circuits, thereby reducing the ability of the atrium to fibrillate. Fortuitously, the surgery also isolated all of the PVs and the posterior LA. In contrast to previous procedures, such as the corridor procedure and LA transection procedures, the Cox-Maze procedure successfully restored both AV synchrony and sinus rhythm and decreased the incidence of late stroke. 1287 This effect was attributed to both AF control and amputation of the LAA. The surgery involved creating multiple strategically placed incisions across both the RA and LA. The surgical incisions were placed so that the sinus node could “direct” the propagation of the sinus impulse throughout both atria. It also allowed most of the atrial myocardium to be activated, resulting in preservation of atrial transport function in most patients. 1288 The final iteration of this procedure, the Cox-Maze III, became the standard for the surgical treatment of AF. Long-term outcomes of 198 patients who underwent the Cox-Maze III procedure for treatment of paroxysmal (n = 113) or persistent or long-standing persistent AF (n = 85) have been reported. 1289 The mean follow-up was 5.4 6 2.9 years. Among the 112 patients who underwent surgery only for AF treatment, 96% were in sinus rhythm with or without AAD therapy and 80% were in sinus rhythm and free of AAD therapy at the last follow-up. Among the 86 patients who underwent AF surgery in conjunction with other cardiac surgery, 97% were in sinus rhythm with or without AAD therapy and 73% were in sinus rhythm free of AAD therapy. The incidence of major complications among the 112 patients who only underwent AF surgery was 11%. Among these were two perioperative deaths and two perioperative strokes or TIAs. Nine patients (8%) required pacemaker placement. The incidence of major complications among the 86 patients who underwent AF surgery at the time of other cardiac surgical procedures was 14%. Among these were one perioperative death and one perioperative stroke. Twenty patients (23%) required pacemaker placement. In considering the results of these early reports of cardiac surgery for treatment of AF, it is now recognized that these patients did not undergo rigorous follow-up by present standards. Rhythms were documented by means of a mailed questionnaire, telephone interview, and/or an ECG for documentation. It is clear that the pioneering work of Cox and his team paved the way for the current, less invasive Cox-Maze IV surgery and other surgical approaches for AF ablation, as well as the field of endocardial catheter ablation of AF. The term lone AF holds different meanings in EP jargon compared with surgical jargon. Electrophysiologists refer to lone AF when there is no other structural heart disease present. Surgeons often refer to a lone AF procedure as one in which the only surgical procedure performed is the ablation as opposed to a concomitant procedure. To eliminate confusion, we recommend that surgeons avoid using lone AF to describe populations of AF patients, and furthermore, we recommend the term stand-alone ablation when no other concomitant procedure is performed at the same operative encounter. As noted earlier in the document, the writing group recommends that the term lone AF not be used in any context related to AF or AF ablation. Surgical Ablation Technology Despite its efficacy, the Cox-Maze procedure did not gain widespread application due to its complexity, technical difficulty, and morbidity. The development and subsequent availability of technology to perform atrial ablation allowed surgeons to replace some of the traditional cut-and-sew lesions with ablation lines using this technology. The simplified Cox-Maze procedure lessened procedural morbidity, thus leading to wider adoption and extending its benefits to more patients. Although a variety of energy sources for ablation were initially developed, only cryothermy and RF energy delivery have emerged as practical and efficacious. The only surgical ablation system approved and specifically labeled for surgical AF ablation is the Atricure Ablation System, which includes a number of ablation tools, including a bipolar RF clamp. 1290 Cryothermy can be thought of as nondirectional (although shielding mechanisms can be employed), whereas RF is a directional source. The RF technologies can be organized into two major groups: unipolar and bipolar. Bipolar RF can be directional bipolar or constrained bipolar. The directional bipolar devices have two side-by-side poles that are applied to the tissue surface, with the energy passing through the tissue between them. As the tissue between the poles desiccates and the impedance rises, the energy passes deeper into healthy tissue, with the goal of tissue transmurality. The constrained bipolar devices consist of a clamp with two jaws, which are applied on opposite sides of the atrial tissue. The energy passes through the tissue between the two jaws. When conductance falls, transmurality is inferred. The unipolar devices do not provide the surgeon with a trans-murality indicator. Since most of these ablation systems were released clinically without dose-response studies, their use has led to occasional collateral cardiac and extracardiac damage. 1162,1291,1292 Moreover, both unipolar and directional bipolar energy sources have had difficulty creating transmural lesions when used from the epicardial surface on the beating heart. 1293,1294,1295,1296,1297,1298 This difficulty occurs because the circulating intracavitary blood pool produces convective cooling, which makes transmural lesions difficult to achieve. 1299 In an attempt to obviate this problem, one device provides suction to pull two walls of atrial tissue into apposition in a shallow trough, thus excluding the circulating heat sink of intracavitary blood while the energy is applied. All of these energy sources have a fixed depth of penetration, which makes their use in pathologically thickened atria problematic. Bipolar RF ablation has overcome some of these shortcomings. Because energy is delivered between two closely approximated electrodes embedded in the jaw of a clamp device, the energy is focused and results in discrete lesions. The energy is confined to between the jaws of the clamp, reducing the possibility of collateral cardiac or extracardiac damage. By measuring the tissue conductance between the two electrodes, algorithms have been developed that help predict lesion transmurality in the experimental laboratory. The weakness of these devices is that they can only ablate tissue that can be clamped within the jaws of the device. This problem has limited the potential lesion sets, particularly in the beating heart. Moreover, in the clinical situation, multiple ablations have often been required to achieve entrance and exit block. These devices have been incapable of fully ablating the RA and LA isthmus and have required adjunctive cry-othermy, or unipolar or directional bipolar RF ablation to perform a complete Cox-Maze III lesion set. Nevertheless, the development of these new ablation technologies has benefited the surgical treatment of AF by making a technically difficult and time-consuming surgery easier for all cardiac surgeons to perform. At present, more than 50% of the patients undergoing open-heart surgery who have AF are offered concomitant AF surgery. 1300 Replicating the full Cox-Maze lesion set with linear lines of ablation has been shown to be both feasible and clinically effective. A number of groups have reported excellent results with ablation-assisted Cox-Maze procedures. 1301,1302,1303,1304,1305,1306 The largest of these experiences included 282 patients who underwent the Cox-Maze IV procedure over a 7-year period with either paroxysmal (n = 118), persistent (n = 28), or long-standing persistent AF (n = 135). 1301 A total of 124 patients (44%) underwent surgery only for AF treatment, and 158 patients (56%) had other cardiac surgery performed, which included mitral valve surgery in approximately 50% of patients. Among the entire patient cohort, 89% of the patients were in sinus rhythm with or without AAD therapy, and 78% were in sinus rhythm and free of AAD therapy at 12 months of follow-up. In contrast to early studies on surgical AF ablation, more intensive monitoring was performed with Holter monitors every 3 months in 70% of the patients. The incidence of major complications was 11%, including an operative mortality of 2% and a 1.7% incidence of stroke. Pacemakers were implanted in 9% postoperatively. A propensity analysis, matching patients who underwent an ablation-assisted Cox-Maze with those having had a traditional cut-and-sew Cox-Maze III, showed no differences in freedom from AF at 3, 6, and 12 months of follow-up. 1307 Further recent work has shown significantly improved results when the entire posterior LA is excluded by the so-called box lesion. 1306,1308 A long-term study followed 576 patients from 2002 to 2014 with long-term monitoring. 1306 At 5 years, freedom from ATAs was 73% (102 of 139) and freedom from ATAs off AADs was 61% (80 of 135). There was no difference in outcomes between patients with PAF or the more persistent forms. There was also no difference between outcomes for those patients who had stand-alone procedures and those who had concomitant procedures. Because outcomes were significantly better at 12 months of follow-up (92% freedom from ATAs overall and 88% freedom from ATAs off AADs), this paper highlights the importance of long-term follow-up. Currently, the limitations of the energy delivery devices and the attempt to deploy them through minimal access incisions or ports place constraints on the location and number of ablation lesions that can be performed. The impact on results of these alternative lesion patterns and the less invasive surgical approaches requires further observational prospective analysis and randomized trials. There has only been one completed trial of concomitant surgical AF ablation that has resulted in specific FDA labeling for clinical treatment of AF. 1290 This was the Atricure Synergy Ablation System trial intended for the ablation of persistent and long-standing persistent AF in patients who are undergoing open concomitant coronary artery bypass grafting (CABG) and/or valve replacement or repair. The principal device used in this trial was an Atricure Synergy Ablation clamp. This system had originally been approved by the FDA for soft tissue ablation without specifically labeling for AF ablation. This prospective nonrandomized clinical trial, using a Bayesian adaptive design with prespecified early stopping rules, enrolled 55 patients between February 2008 and June 2009. Along with concomitant cardiac surgery, investigators performed the Cox-Maze IV lesion set. The median patient age was 72 years, the median EF was 50%, and the median LA size was 6 cm. 56% of patients underwent valve surgery alone or in conjunction with CABG. The incidence of major adverse events was 9%, including death in 2 patients (3.6%), major bleeding in 2 patients (3.6%), and stroke in one patient (1.8%). In addition to these major complications, 25% of the patients required implantation of a permanent pacemaker for AV node dysfunction (8.3%) or sinus node dysfunction (17%). The effectiveness of the procedure was assessed in 50 evaluable patients, excluding four patients who died and one withdrawal. At 6 months of follow-up, 74% of the patients were AF-free and off AAD therapy, and 84% of the patients were free of AF on or off AAD therapy. The freedom from AF at 12 months of follow-up was also 75%. The results of this study were reviewed at an FDA panel meeting, leading to approval for clinical use in 2011. This surgical ablation system is currently the only system specifically labeled for treatment of AF. We recommend that the term Maze procedure is appropriately used only to refer to the biatrial lesion set of the Cox-Maze surgery. It requires ablation of the RA isthmus and the LA isthmus. Less extensive lesion sets should not be referred to as a Maze procedure, but rather as a surgical AF ablation procedure. In general, surgical ablation procedures for AF can be grouped into three different groups: (1) a full biatrial Cox-Maze procedure, (2) PVI alone, and (3) PVI combined with LA lesion sets. Surgical Technology for Appendage Ligation or Removal and Outcomes of These Procedures The LAA is a site of thrombus formation in patients with AF. Retrospective evaluation has suggested that the LAA is responsible for up to 90% of the strokes in patients with AF and nonrheumatic heart disease. 1309 Accordingly, it has been the target of elimination in the original Cox-Maze, as well as in the majority of its modifications. Early evaluation of the cut-and-sew Cox-Maze suggested a reduction of stroke late after surgery. 1287 Other small, retrospective series subsequently suggested a lower-than-expected incidence of late neurological event (stroke or TIA) after a Maze, possibly independent of 1287,1310,1311 The CHA2DS2-VASc score. reduction in stroke has been attributed to a combination of sinus restoration and LAA elimination. The role of the LAA has been clouded by small numbers of patients and the continuation of anticoagulation in a minority of postoperative patients, as well as a retrospective series suggesting a persistent stroke risk in postoperative patients who are in sinus rhythm, with large atria, and poor atrial contraction leading to effective LA asystole. 1312 The strongest evidence that LAA elimination decreases stroke comes from the WATCHMAN Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation (PROTECT AF) and WATCHMAN LAA Closure Device in Patients With Atrial Fibrillation Versus Long Term Warfarin Therapy (PREVAIL) trials that randomized patients to either anticoagulation or implantation of a WATCHMAN device in the LAA. The 4-year results of the PROTECT AF trial suggested that elimination of the LAA was superior to anticoagulation for the composite endpoint of cardiovascular death, all stroke, and systemic embolization. 1313,1314 An important concern for surgical excision has been the complication of bleeding. This complication is especially important in older patients and those with enlarged atria in whom the tissue may be more friable. This has led to several different techniques for LAA elimination at the time of surgery. The most common have been internal ligation (e.g., sewing the LAA orifice closed from the inside) and stapled excision. There is a paucity of data that examines effectiveness of any surgical technique. However, with stapled excision, reported rates of tears requiring repair have been approximately 10%. 1315,1316 Another issue is the potential for arrhythmia generation from the LAA. One study demonstrated LAA firing in 29% of patients and the only site of recurrence in 8.7% of patients who had undergone catheter ablation of paroxysmal or persistent AF; additional LAA isolation could increase the freedom from AF. 532,533 Thus, the isolation or surgical excision of the LAA could influence procedure efficacy and reduce the risk of thromboembolic events. However, a randomized study including 176 patients with persistent AF who were undergoing surgical ablation via thoracoscopic approach reported that additional LAA amputation did not reduce the rate of any atrial arrhythmias compared with the standard surgical ablation set. The follow-up period of this study was 18 months and the results cannot be extrapolated to the long-term maintenance of sinus rhythm or thromboembolic events prevention. 1317 An emerging concern is the effectiveness of these alternative techniques. Most evidence is anecdotal and revolves around case reports because the LAA is not routinely evaluated late after surgery unless there is a clinical indication. In a series of 137 such patients, the LAA was incompletely ligated (either leaving a stump greater than 1 cm or a gap with flow) in 27% of patients after surgical excision. In internally ligated patients, the failure rate was 77%. There were no successes when the LAA was stapled without amputation of the distal remnant. 1318 One limitation of this small series is that it only looked at the 5% of patients who received intervention who had an indication for late TEE, which included only 12 in the stapled group. A more recent small, randomized trial of internal ligation, surgical excision, and stapled excision reported that, at TEE evaluation in follow-up of 5 months, all three of these techniques left either a stump or a gap at least 50 percent of the time. 1319 Epicardial LAA ligation with a LARIAT device has been developed through the combined transseptal and subxiphoid approach. 1320 The results from the multicenter registry demonstrated a high acute closure rate, but procedural success was limited by bleeding. 1321 More recent results showed that LARIAT device implantation was associated with a lower rate of leaks at 1 year of follow-up and a 1.1% rate of TIA or stroke. 1322 Newer techniques include an external clip (Atriclip) that was approved by the FDA in 2011 for the occlusion of the LAA under direct visualization in patients undergoing other open cardiac surgical procedures, as indicated in the approved Indication statement of the AtriClip device. This study reported 98% success in 60 of 71 patients available for follow-up. 1323 A longer-term study followed 36 patients with annual CT scans. 1324 At 3.5 years of follow-up, all the clips were stable with no thrombi, no LAA perfused, no neck >1 cm, and no neurological events. The use of an endo-loop has been described, as well as a silicone fastener, which is not currently available (Tiger paw). The true efficacy of any single technique is unknown and will require more investigation before any recommendations can be made. There are data that suggest that despite the limitations of all these techniques, a reduction in strokes might occur. One series of 773 patients undergoing surgery for AF compared surgical excision with alternative techniques. The annual rates of late neurological events was approximately 1% using alternative techniques, and only one event was fatal. 1325 This suggested at least a reduction of clot burden even in incompletely successful techniques. Our understanding of surgical elimination continues to rapidly evolve, and current studies are inadequate to make a distinction between LAA excision or exclusion techniques. It is reasonable and probably helpful to eliminate the LAA with any technique at the time of AF surgery, but late evaluation should be performed prior to cessation of anticoagulation. We have elected not to make recommendations regarding appendage occlusion, resection, or ligation in this document, because this is beyond the scope of this document and available data. Concomitant Surgical Ablation Historical Considerations Surgical ablation is most commonly applied as a concomitant procedure during valve or CABG surgeries. Prior consensus recommendations referred to cardiac surgery as a whole, grouping data from multiple studies to derive IIa LOE C recommendations. 2 However, that document went on to say, “It is advisable that all patients with documented AF referred for other cardiac surgeries undergo a left or biatrial procedure for AF at an experienced center, unless it… will add significant risk….” 2 More recent AHA/ACC/HRS Guidelines continued this procedural grouping but included more recent randomized comparisons to determine that surgical ablation at the time of another surgery is a IIa LOE B recommendation. The frequencies of surgical ablation performance and durable rhythm success have steadily increased. Furthermore, as noted above, the FDA has now approved an ablation system for treatment of persistent AF in patients undergoing concomitant cardiac surgical procedures. 1290 Recently, more information has become available on AF mechanisms and the potential influence of specific structural heart abnormalities on outcome. Therefore, this surgical section provides updated recommendations for three operation categories for which more data are now available: primary open atrial operations, primary closed atrial operations, and stand-alone operations for AF. Concomitant Surgical Ablation Open concomitant cardiac surgical operations, in which a left atriotomy is being performed for the primary procedure, commonly include patients receiving mitral valve repair or replacement (MVRR), with or without concomitant tricuspid valve repair or replacement, or closure of an ASD. Closed concomitant surgical ablation operations, in which a left atriotomy is not otherwise performed, commonly include patients undergoing prosthetic AVR, CABG, or AVR+CABG. The prevalence of preoperative AF and frequency of concomitant cardiac surgical operations varies between these procedure classes. AF is found in one-third of patients presenting for mitral valve surgery, but in only 6% of patients undergoing isolated CABG, and in 14% of patients at the time of AVR. Mitral valve repair for primary regurgitation has largely supplanted mitral valve replacement and does not require lifelong anticoagulation. Thus, successful surgical ablation concomitant to mitral repair can mitigate the need for long-term anticoagulation or medicinal therapy for AF. The performance rate of concomitant cardiac surgery in patients with AF at the time of mitral operations has risen from 52% to 62%. In an analysis of operations performed in the early 2000s, the likelihood of surgical ablation performed for AF at the time of AVR was 31%, and only 26% at the time of CABG. Although differential application of surgical AF ablation exists among operative procedures, more recent information suggests an acceleration of surgical AF ablation, especially in the mitral subgroup. Surgical Ablation at the Time of Concomitant Open Atrial Operations At the time of a primary atriotomy, AF surgery can be performed during concomitant MVRR with or without tricuspid surgery, with or without closure of ASD, and with or without other concomitant procedures such as CABG. 1326 The results of the only prospective study performed to achieve FDA labeling for AF ablation reported a 9% major complication rate, a 25% rate of pacemaker implantation, and a 75% freedom from AF at 12 months of follow-up among 54 consecutive patients with persistent AF undergoing other types of cardiac surgery who were enrolled in this clinical trial. 1290 Several other RCTs and meta-analyses are available to evaluate AF surgery at the time of concomitant mitral procedures. 1327,1328,1329,1330,1331,1332,1333,1334 Large LA, AF duration, advanced age, and failure to isolate the entire posterior LA are common predictors of reduced long-term efficacy. High baseline comorbid risk is a common reason cited for not performing surgical ablation, though many institutional studies note that this is not a contraindication to surgical ablation. The safety of concomitant surgical ablation has been established in the literature and in updated valve risk models from the STS database. A multivariable regression and propensity matched cohort, composed of 52% mitral procedures from the STS database, demonstrated no impact on 30-day mortality with surgical AF ablation. 1300 However, patients undergoing surgical AF ablation had a 26% higher chance of requiring a permanent pacemaker (OR 1.26). In a recent randomized trial of mitral valve operations, there was no increase in major complications associated with the addition of surgical ablation other than a doubling of pacemaker risk. 1331,1333 Conversely, recent large meta-analyses confirmed the safety of concomitant surgical ablation, but did not find a significant increase in pacemaker use. The incidence and outcome relevance of pacemaker implantation remains a point of controversy. In analyses of more recent STS data, risk-adjusted mortality was either not impacted or actually decreased with surgical AF ablation in the mitral and multiple valve populations. 1335 A longitudinal study (up to 120 months) demonstrated that restoration of sinus rhythm by a Cox-Maze procedure combined with heart surgery markedly increased long-term survival. 1336 Despite previously published variability of efficacy of surgical ablation in heterogeneous populations, the longitudinal benefits of concomitant surgical AF ablation at the time of MVRR are now becoming clearer. Several recent RCTs and meta-analyses indicate that concomitant surgical ablation at the time of MVRR reduces the longitudinal incidence of postoperative AF greater than 50% for at least 1 year, with results ranging from 60%–90%. 1327,1328,1329,1330,1331,1333, 1334,1337,1338 In addition to LA size and preoperative AF duration, there is a procedural learning curve that can impact efficacy, and thus surgeons should seek appropriate training prior to performing surgical ablation. Therefore, based on the literature and the experience of the writing group members, surgical ablation for AF is recommended at the time of concomitant open atrial procedures, such as mitral valve surgery in patients with symptomatic AF (Class I, LOE B-NR) (Table 2, Figure 8). Surgical Ablation at the Time of Concomitant Closed Atrial Operation Concomitant surgical ablation of AF at the time of primary nonatriotomy operations includes patients undergoing isolated AVR, isolated CABG, or AVR+CABG. The presence of AF at the time of these operations, especially if left untreated, is associated with increased risk of early and late mortality and morbidity. When no intracardiac pathology exists in the setting of AF, further surgical decision-making is required. Although full open Cox-Maze IV has been shown to be safe and effective in these cases, surgeons are reluctant to add a left atriotomy to address AF. If less aggressive approaches, such as epicardial PVI or the Dallas lesion set are to be applied, care should be taken to note the mechanism and type of AF being treated. 1339,1340,1341 Recent randomized and matched cohort studies of surgical ablation and concomitant AVR, AVR+CABG, and isolated CABG all consistently show no differences in 30-day or inhospital morbidity or mortality. 1342,1343,1344 We have known that at the time of isolated CABG operations, the open atrial Cox-Maze procedure is effective upwards of 90% at 5 years of follow-up. 1345 The application of bipolar RF clamps to perform PVI has shown variable 50%-89% 1-year success superior to AAD alone in patients with paroxysmal and persistent AF. 1346,1347,1348,1349,1350 A recent meta-analysis of 16 RCTs of surgical ablation and concomitant operations evaluated predominantly mitral operations, but included both AVR and CABG operations. 1333 There were no significant differences in mortality, stroke, or pacemaker requirement between surgical ablation compared with no ablation; however, the surgical ablation groups demonstrated superior 1-year freedom from AF in AVR and AVR+CABG. Therefore, based on the literature and the experience of the writing group members, surgical ablation for AF is recommended at the time of concomitant closed atrial procedures such as isolated AVR, isolated CABG, and AVR+CABG in patients with symptomatic AF refractory or intolerant to at least one Class I or III antiarrhythmic medication (Class I, LOE B-NR) (Table 2, Figure 8). For symptomatic patients with AF who have not previously been treated with antiarrhythmic therapy, concomitant closed AF surgery is recommended with a Class IIa indication, LOE B-NR (Table 2, Figure 8). At the time of a planned cardiac operation for symptomatic structural pathology, it should be noted that interpreting symptoms of concomitant AF as distinct might or might not be feasible because these could be masked by symptoms prompting the primary cardiac operation (i.e., valvular or coronary disease). Therefore, in the setting of existing symptomatic surgical pathology, the presence or absence of AF symptoms should not be the only factor involved in surgical decision making on the concomitant performance of surgical ablation. It should be noted that the surgeon members of the writing committee, as well as other surgeon reviewers, felt that the evidence might warrant a Class I indication for this patient subgroup; however, among the larger group, consensus was attained for a level IIA recommendation. Stand-Alone Surgical Ablation of AF Stand-Alone Operations for AF and Their Outcomes The primary indication for stand-alone surgery that was described in the 2012 Consensus Document was the presence of symptomatic AF, refractory or intolerant to at least one Class I or Class III AAD. 2 In current practice, most patients also have experienced at least one unsuccessful catheter ablation before referral, unless the patient has a strong preference for a cure with a single procedure. There has been over two decades of experience with operations performed solely for treatment of AF (stand-alone operations). The wide use of these procedures has been limited by a reluctance to refer patients to surgery for AF, procedural complexity, and limited data regarding outcomes. Moreover, the types of procedures and the technologies used to perform them have multiplied and are variable between operators. This has led to relatively modest-sized single-site case series, or at best multicenter series without comparison groups. In addition, the rigor and methodology of follow-up have changed dramatically over time and have further limited comparisons of outcomes. Lastly, the development of hybrid procedures, especially when staged, make comparisons even more difficult. This section will focus only on single-stage surgeries as sole AF therapies. A discussion of hybrid procedures will follow. Perhaps the best way to distinguish the types of surgeries is by those that require cardiopulmonary bypass and cardiac arrest and those that do not. In order to effectively create a lesion down to the mitral annulus, an open heart is required. The earliest—and one of the largest—reported study of stand-alone operations for AF has been the 112 patients who underwent the cut-and-sew Cox-Maze III procedure by James Cox. 1351 This procedure is performed through a sternotomy on cardiopulmonary bypass on an arrested heart and physically cuts and re-sews the atria to create a collection of lines of block. Cryothermia is used to destroy the tissue down to the mitral annulus. Among the 112 patients, 96% were in sinus rhythm with or without AAD therapy, and 80% were in sinus rhythm and free of AAD therapy at last follow-up. There was one late stroke in this group, and 88% of the patients were off chronic anticoagulation at last follow-up. The only risk factor for late recurrence was the preoperative duration of AF. 1351 There have been several other published series with similar results that combine both stand-alone and concomitant patients with smaller numbers of patients. This procedure requires a sophisticated level of training and skill. As such, it is performed rarely, and only by experienced surgeons. Ideal patients for stand-alone AF ablation have failed other therapies, want definitive cures, or have clots in the LAA, making other approaches not using cardiopulmonary bypass risk prohibitive. With the introduction of new ablation technology, including bipolar RF energy and new cryoablation systems, there has been renewed interest in less invasive procedures for stand-alone AF ablation. These new tools can be used in the open chest or through small incisions between the ribs. When used in the open chest with a full biatrial Cox-Maze lesion set performed, the procedure has been termed the Cox-Maze IV procedure. Techniques for a Cox-Maze IV procedure through a small, right inframammary incision have also been perfected. As noted in the earlier section on new surgical ablation technology, the outcomes achieved with the Cox-Maze IV procedure are similar to those achieved with the earlier Cox-Maze procedure. Importantly, the cross-clamp times are shorter with the Cox-Maze IV procedure. 1301 The advantage of these approaches includes the ability to reliably create the endocardial lesions of the Maze, down to the mitral annulus. Late evaluation of this procedure in 146 stand-alone patients has shown a 72% freedom from AF at 5 years of follow-up and a 59% freedom from AF off antiarrhythmic medications. 1306 Cryothermia alone has been used and described in a series of 77 patients, with a 6-month result of 88% freedom from AF, antiarrhythmic medications, and anticoagulants, but late follow-up is lacking. 1306,1352 Other approaches have limited the lesions to only those that can be created from the epicardium without the need to open the heart, and use both cardiopulmonary bypass and cardiac arrest. This approach has limited the extent of lesions from the Maze that can be created, because the mitral line is buried by an epicardial fat pad that makes destruction of tissue in this area unreliable. The minimally invasive surgical approach using video-assisted PV ablation and exclusion of the LAA was first described in 2005. 1353 A bipolar RF clamp was used for PVI on the beating heart in 27 patients, among whom 18 had PAF. Among the 23 patients followed for more than 3 months, 21 (91%) were free of AF and 65% were off all AADs. There were four major complications, but no deaths, and no pacemakers were implanted. An additional ablation strategy that has been reported is minimally invasive PVI and partial autonomic denervation. 1354 In a study of 74 patients undergoing this approach, 84% of the patients with PAF were free of AF and 57% of patients with persistent or long-standing persistent AF were free of AF at 6 months. There was one death, one hemothorax, one case of transient renal insufficiency, and one patient with a transient brachial plexopathy. A second, larger report from this group in 114 patients reported that 72%, 46.9%, and 32% of patients with paroxysmal, persistent, and long-standing persistent AF, respectively, were free of AF and off antiarrhythmic medications at 195 days of follow-up. 1355 Another multi-center series of 100 patients with a similar approach and mean follow-up of 13.6 months reported a sinus restoration rate of 87%, with 64% of patients free from AADs. 1356 The results of these and other trials cited earlier in this section have made it clear that a more extensive lesion set than PVI alone is required for successful surgical treatment of persistent and long-standing persistent AF. Most surgeons who still perform this type of procedure have moved toward a hybrid approach in either a single or staged operation. However, a PVI alone remains a reasonable approach for patients with PAF. The Dallas Lesion Set was developed to create a complete approach, which can be performed on a beating heart without cardiopulmonary bypass. 1339,1340,1341 The set replicates the LA lesions of the Cox-Maze III, but changes the connection of the PVI to the aortic annulus in continuity with the mitral. Early results have been published on 30 patients. 1339,1340 The group included 10 patients with persistent AF and 20 patients with long-standing persistent AF. Electrocardiographic long-term monitoring and the use of AAD data were collected 6 months postprocedure, and follow-up was 100%. Procedure-related complications did not occur during follow-up, nor were there any deaths. At 6 months of follow-up, 90% of the patients with persistent AF and 75% of the patients with long-standing persistent AF were in sinus rhythm. AAD therapy was continued in 22% of the patients with persistent AF and 53% of the patients with long-standing persistent AF. In a series of 100 paroxysmal patients randomized to include the Dallas Lesion Set or not, the additional lesion, as expected in a paroxysmal population, did not impact success at 16 months of follow-up. 520 Much like the results of catheter ablation, this suggests that the type of AF will influence the success of the procedure. Persistent AF is likely to require a more extensive lesion set. An important area of interest is the decision to offer a patient surgery or catheter ablation. The AF Catheter Ablation Versus Surgical Ablation Treatment (FAST) trial sought to compare catheter ablation with minimally invasive surgery. 601 A total of 124 patients who had drug-refractory AF with dilated atria or failed catheter ablation were randomized to either catheter ablation or minimally invasive surgery using bipolar clamps, with or without additional connecting lesions. At 1 year of follow-up, freedom from AF was 37% in the catheter ablation group and 66% in the surgical group. Although this was somewhat offset by the increased adverse events in the surgical group (34% vs 16%), the only death was in the catheter ablation group. 601 A different analysis of 7 studies, including two RCTs, suggested superior freedom from AF in the surgical group, with similar complication rates, except for an increase in pacemaker implantation in surgical patients. 1357 However, the technologies and groups were fairly heterogeneous. Other approaches, such as epicardial box lesions with suction-assisted unidirectional uni- and bipolar RF and a complete box lesion with bipolar clamps, have been described in numbers insufficient to draw any conclusion. As the new techniques have been introduced, there has been appropriate concern regarding the safety of minimally invasive stand-alone surgery. Although safety is dependent on procedure and site, it has been examined in a systematic review that compiled results from 23 observational studies with 752 patients who underwent minimally invasive stand-alone procedures. 1349 Operative mortality was 0.4%. Complication rates attributed to surgery were only 3.2%. Reports from the STS National Database showed an operative mortality rate of 0.74%. The complication rate was considerably higher at 16.43%, although major morbidities such as stroke (0.72%), renal failure (2.45%), and bleeding (0.99%) were low. Pacemakers were implanted in 1.03% of patients. The outcomes of stand-alone AF ablation from the STS database were recently reported. 1358 Between 2005 and 2010, a total of 91,801 surgical AF ablations were performed, of which 4893 (5.3%) were stand-alone. During this period of time, the number of stand-alone AF surgeries increased from 552 cases in 2005 to 1041 cases in 2010. The mean age of the stand-alone group was 60 years, and 71% were men. Some 80% of the stand-alone procedures were off pump. The overall operative mortality was 0.74% (1.7% on pump vs 0.5% off pump), the rate of pacemaker implantation was 1%, and the overall complication rate was 16% (28% on pump vs 13% off pump). 1358 The Atrial Fibrillation Ablation and Autonomic Modulation via Thoracoscopic Surgery (AFACT) study compared the outcomes of thoracoscopic surgical AF ablation in 240 patients with advanced AF at a single European center. 123 A total of 59% of the patients had persistent AF and 68% had an enlarged LA. One-fourth of these patients had previously failed catheter AF ablation. Patients were randomized to undergo surgical AF ablation alone or combined with epicardial ablation of the four major GP. At 12 months follow-up, no recurrences of AF were observed in 71% and 68% in the GP and control groups, respectively; the incidence of major complications was greater in the group that underwent GP ablation (19% vs 8%, respectively). Major bleeding occurred in nine patients in the GP group, one of whom required sternotomy. Sinus node dysfunction occurred in 12 patients in the GP group and in 4 controls. The authors concluded that GP ablation during thoracoscopic surgery for advanced AF is associated with higher risk and no appreciable improvement in AF control. This center also recently examined the 5-year outcomes of thoracoscopic surgery for AF in 66 patients. A total of 50% of patients experienced no AF recurrences and discontinued AAD therapy at the 5-year follow-up, and 88% of the patients were in sinus rhythm. In this cohort, persistent AF and previous failure of catheter ablation were independently associated with AF recurrence. 1359 Superior efficacy of a single approach has also been difficult to establish. A systematic review of 48 studies including 3832 patients suggested that the efficacy of bipolar RF was equivalent to the cut-and-sew Maze III technique for stand-alone surgical ablation, as long as both were applied meticulously. 1360 Another meta-analysis of 16 published randomized trials indicated that the cut-and-sew Maze III produced slightly better recovery of SR and stroke prevention, but with increased perioperative risk. 1361 Definitive recommendations for a surgical approach with or without cardiopulmo-nary bypass await more data. Using a surgical approach with or without cardiopulmonary bypass that creates all, some, or a modification of the maze is reasonable, especially in patients in whom catheter ablation has failed or who are at high risk for an unsuccessful catheter-based result. However, a stand-alone operation should have the ability to create the complete full Maze lesion set, whether it is in a single operation or staged. This approach is especially important for those patients who have persistent AF. Therefore, based on the literature and the experience of the writing group members, stand-alone surgical ablation of paroxysmal AAD-refractory AF can be considered for patients who have failed one or more attempts at catheter ablation, and after review of the relative safely and efficacy of catheter ablation vs a stand-alone surgical approach for those who are intolerant or refractory to AAD therapy and prefer a surgical approach (Class IIb, LOE B-NR). For patients with persistent and long-standing persistent AF, stand-alone surgical ablation is reasonable for patients who have failed one or more attempts at catheter ablation, and after review of the relative safely and efficacy of catheter ablation vs a stand-alone surgical approach for those who are intolerant or refractory to AAD therapy and prefer a surgical approach (Class IIa, LOE B-NR, Figure 8). Stand-alone surgical AF ablation is not recommended for patients who have not failed a trial of at least one antiarrhythmic medication. Catheter Ablation After AF Surgery The idea of a “touch-up” ablation for AF recurrence is not new to catheter ablation. It is, however, relatively new to the treatment algorithms of failure after cardiac surgery for AF, which has historically been considered the end of the road for sinus restoration. Now, catheter ablation can be a critical adjuvant for patients who undergo surgical AF ablation yet still suffer from residual AF. The potpourri of surgical AF treatment—ranging from PVI through complete LA to complete biatrial lesions and combinations in between—makes standardized conclusions difficult in this area. This endpoint is further obscured by the myriad of technologies used to create the lines of block, as well as the underlying type of fibrillation treated and the limited number of patients in published series. However, there are several publications that offer some guidance, which will be reviewed below. What has become clear over time is that, as with redocatheter AF ablation procedures, finding a reconnection of the PVs is also to be expected in a patient undergoing a catheter-based AF ablation procedure following a surgical AF ablation procedure. Because the cut-and-sew Maze was the earliest described procedure, initial reports focused on patients who underwent that specific procedure. One of the earliest studies reported on 23 patients who presented a mean 14 months after a cut-and-sew Maze. In this report, 8 patients had only undergone a Maze, and 15 had undergone a concomitant procedure. 1361 The most common site of failure was around the PVs, which occurred in eight (35%) patients. Five patients had focal tachycardia (3 in the CS and 1 each in the posterior lateral RA and LA septum). Four patients had RA incisional flutter and six had left AFL, which mapped around the mitral valve annulus in four patients and around the PVs in two. One year after ablation, 19 of the 23 patients were both arrhythmia-free and off AADs. The vulnerability of PVI was supported by another study that followed 20 patients with arrhythmias after surgical ablation. 1362 This group, however, was much more heterogeneous: alternative energy sources were used to create the initial lines of block, including microwave, RF, cryothermy, and laser; most patients had only LA lesion sets at the time of initial surgery, and nearly half the patients had more than one mechanism of tachycardia. This report also highlighted the involvement of the mitral isthmus, including the CS and the LAA. The vulnerability of the mitral isthmus, especially at the CS, was also highlighted in a series of 22 patients failing after the Cox-Maze III. 1363 Of note, this outcome represented a 15% failure rate among a total of 143 patients in whom lesions were created using a combination of cut-and-sew and cryothermy. Frequently, out of concern for injury to the circumflex, cryothermy is used at the mitral annulus and is often used to connect the PVs in a small area so that reapproxima-tion of the tissue is easier. In a series of patients with five different surgical types, various rates of failure were identified. 1364 High-intensity focused ultrasound was associated with a 37.5% need for touch-up catheter ablation, which was much more frequent than the other groups. This group had failures primarily around the PVs, suggesting an incomplete lesion creation at initial operation. The other groups—consisting of cut-and-sew Maze, biatrial Maze using primarily RF, LA maze alone, and PVI alone—had no significant difference in success, ranging from 90% for the cut-and-sew to 69% for PVI alone. When the RA was not addressed at the time of initial operation, it was the site of failure in 75% of those who had recurrent AF. In the other groups, the mitral isthmus was again identified as an area for failure. Successful ablation was achieved in approximately 70% of patients. These findings have relevance as new paradigms for treatment evolve. Using hybrid strategies with technology that replaces cut-and-sew and new lesion sets might require a more individualized approach to each patient. New technology can introduce an area of vulnerability around the PVs. In one series of 154 patients undergoing minimally invasive PVI, eight failures were studied. Half had gaps in the lesions created with new enabling technology. 1365 The remainder had flutters around the mitral isthmus. In a series that compared a cut-and-sew Maze to a hybrid approach, only 8% of the patients needed ablation after a cut-and-sew Maze. 1366 However, after PVI using bipolar RF, 7 of 25 (29%) patients needed a second-stage catheter ablation. All seven had at least one failure around the PVs, for a total of 15 veins. Reconnection was most common in the RI region. Interestingly, there were no RA failures in this group. These reports suggest that there are many factors for surgical failures after AF treatment. It is likely that catheter ablation can help selected patients restore sinus rhythm after failures. These treatments should be performed at experienced centers by experienced individuals who will tailor the procedure to the individual patient based on initial lesion set, the ablation technology and strategy used during initial AF surgery, and the results of extensive mapping and provocative testing at the time of the redo ablation procedure. As the experience with new hybrid approaches evolve, more definitive conclusions should arise. Hybrid Epicardial and Endocardial AF Ablation Procedures Background Forward-thinking practitioners view catheter AF ablation and minimal access surgical ablation as complementary rather than competitive techniques, having found that patients who fail a surgical ablation usually fail as paroxysmal with a relatively low burden of AF. Whereas they might not have been candidates for catheter AF ablation preoperatively, they are now ideal candidates for a “touch-up” catheter AF ablation. The electrophysiologist will frequently find a single small break in a line, which is easily completed with a catheter; thus, the procedure is converted to a success. This realization of the complementary nature of these disciplines has led some to believe that perhaps combining these approaches could lead to better outcomes than either approach alone. There are other reasons why surgical (epicardial) and catheter (endocardial) ablation can be viewed as complementary. Surgical devices can fail to penetrate the endocardium; catheter devices can fail to penetrate to the epicardium. Surgeons are skilled at making lines; the tools are designed for it, the smooth epicardial surface is ideal for it, and visual imaging can reveal breaks in a line. Electrophysiologists excel at “spot welding.” The catheter tip is punctuated by design, so it can slip off of endocardial ridges or trabeculations, resulting in breaks, and nonvisual imaging does not show continuity of burns. Surgeons might have difficulty mapping for completeness; they are constrained by pericardial reflections, they might lack formal training, and their tools are first- or second-generation. Electrophysiologists excel at mapping for success; they have full access to the entire endocardial surface, they are formally trained in the techniques, and they have mature enabling technology. In addition, each specialty has its own unique contributions. Surgeons can fully divide the ligament of Marshall, eliminate the atrial appendage, perform targeted ablation of GP, and isolate the SVC with little risk of injury to the PN. Electrophysiologists can easily make a cavotricuspid isthmus line, map for flutters, ablate within the CS, and map and ablate focal triggers. 1367,1368 Recognition of the complementary nature of these techniques has led some centers to explore “hybrid” procedures (combined surgical and catheter ablation), with early promising results. 606 The advent of minimal access surgical ablation laid the groundwork for hybrid ablation. Seeking to advance the success of the Cox-Maze III yet lessen the morbidity, surgeons began exploring minimal-access approaches. Three things led to the expansion of minimal-access techniques: First was the focus on the PVs as the seminal goal of ablation; second, advances in enabling technology allowed lesion creation using RF energy and cryothermy; and third was the published data revealing modest success for catheter ablation of the persistent forms of AF. 2,931 Thus, with the focus on the PV triggers, surgeons began performing an increasing number of minimal-access PVI procedures. 197,1369,1370,1371 However, investigators showed that this treatment was inadequate for patients with persistent and long-standing persistent AF. 1355 This led to the belief that the persistent forms of AF needed both substrate modification and trigger isolation, and this provided the impetus to develop the Dallas lesion set, which replicated all the LA lesions of the Cox-Maze III, yet allowed them to be placed on the surface of the full-beating LA. Although it was a major step forward, with a success rate of 79%, this approach failed to reach the success rates of the Cox-Maze III. 1339,1340 To enhance the robustness of lesion formation, the complementary processes of performing a catheter-based endocardial ablation in combination with surgical epicardial ablation were contemplated, and this led to hybrid approaches. 1372,1373,1374 Though these hybrid techniques are under active investigation, the published literature is limited to a few early feasibility studies. Early investigators used a unilateral right thoracoscopic approach to isolate the PVs with a single encircling box lesion. The energy source for the surgical ablation was monopolar RF (Cobra Adhere, Estech, San Ramon, CA). Nineteen consecutive patients underwent a right unilateral minimally invasive hybrid procedure. Ten patients (52.6%) had long-standing persistent AF, whereas four (21.1%) had persistent and five (26.3%) PAF. 1375 In 17 patients, one or more PVs (mostly the LSPV) were not isolated, and an endocardial touch-up was needed. It was possible to complete all the procedures as planned, without any conversion to cardio-pulmonary bypass. No patient died during the follow-up. At 1 year, 7 of 19 (36.8%) patients were in sinus rhythm with no episode of AF and off AADs. Among the patients with longstanding persistent AF, 20% (2 of 10) were in sinus rhythm and off AAD, 50% (2 of 4) in persistent and 60% (3 of 5) in PAF. Disappointing 1-year results were attributed to an inadequate energy source. Thus, the surgical portion of the procedure was converted to use a bipolar RF clamp (AtriCure Inc., West Chester, OH), which had been shown to be more effective. 1376 This approach provided improved results, and in most cases, gaps in surgical lesions could be completed by endocardial catheter ablation during the same procedure. 608 A sequential hybrid approach was subsequently developed. 606 There are advantages and disadvantages to simultaneous and staged hybrid procedures. An important concern of single-stage hybrid is that edema and stunning induced by surgical ablation might produce block on testing, but these areas might recover later, when edema has subsided. This presence of an incomplete block at delayed catheter mapping was reported by an investigator who performed bilateral PVI box lesion and an additional roofline and LAA exclusion with clips in 30 patients with persistent AF. At staged catheter hybrid 3 months later, they found gaps in 77%–87% of the PVI lesions, nearly 70% of the rooflines, and 40% of the floor lines, requiring endocardial touch-up ablation. Nevertheless, they were able to obtain a 1-year freedom from AF and AAD by 7-day Holter of 90% (27 of 30). Other surgeons compared 25 staged hybrid procedures using bipolar RF with 38 classic cut-and-sew Maze III procedures. 1366 At 1 year of follow-up, freedom from AF and antiarrhythmic medication was 52% for the staged hybrid and 87.5% for the Maze III (P = .004). Other approaches included a unilateral thoracoscopic approach using the monopolar RF suction Estech Cobra Adhere XL device (AtriCure Inc., West Chester, OH) without atrial appendage occlusion, applied to 19 patients. 1375 At immediate hybrid catheter ablation, every lesion required touch-up and 1-year freedom from AF and AAD was 36%. An innovative approach has been the passage of a scope from the subxiphoid, transperitoneal and transdiaphragmatic region to approach the posterior LA (the convergent procedure). The surgeon uses the nContact monopolar RF coagulation system to produce a comprehensive biatrial lesion pattern on the outside of a beating heart while eliminating chest incisions. Then, the electrophysiologist uses an ablation catheter endocardially to finish the lesion pattern and ensure that all reentrant circuits are interrupted. Reported success rates have varied, from 16.7% to 100%; however, there has been an elevated adverse event rate in most published series, with an associated mortality of up to 12.5%, mostly related to AEF and sudden death. 607,609,613, 1368,1377,1378,1379,1380,1381,1382,1383 This procedure has been largely redesigned to prevent these adverse results, and two papers have reported no mortality and no AEF. 613,1381 A recent meta-analysis compared the Cox-Maze to hybrid procedures. The overall freedom from AF and freedom from AF off AAD at 1-year of follow-up was 87% vs 71%, respectively, but the complication rates were higher with hybrid procedures. 1384 Based on current literature, the hybrid approach with the most effective outcomes and safety profile appears to be the bilateral PVI procedures with LAA management. Available published data on the monopolar convergent procedure do not indicate an adequate safety and efficacy profile. Currently, there is investigation into both simultaneous and staged hybrid procedures, with no clinical trials showing one strategy superior to the other. The Dual Epicardial Endocardial Persistent Atrial Fibrillation trial is a prospective randomized staged hybrid study using bipolar RF. The CONVERGE trial is a set of prospective randomized simultaneous hybrid trials using monopolar RF. These trials also use different operative approaches. There are a number of other ongoing multicenter trials that are likely to define the roles and lesion sets for treatment of patients with persistent AF using these strategies. The hybrid approach could hold significant promise for those patients with persistent or long-standing persistent, drug-resistant AF to offer improved results over minimal access surgical ablation or catheter ablation alone. Based on the literature and the experience of the writing group members, we believe that it might be reasonable to apply the indications for stand-alone surgical ablation described above to patients being considered for hybrid surgical ablation (Class IIb, LOE C-EO, Table 2). The Future The most successful programs in the future might be those that employ an interdisciplinary, collaborative team approach to the treatment of AF, resulting in higher success rates for patients. Many of these patients are well read and mobile and will seek out such centers, thus increasing both catheter and surgical volumes. Practitioners in the future will likely find value to working as part of a multidisciplinary team. The precedent is set for this type of collaboration. The STS, the ACC, the FDA, and the Centers for Medicare and Medicaid Services have joined together to collaboratively introduce transcatheter AVR as a mandatory multidisciplinary team approach with mandatory long-term follow-up. More work is needed in the area of collaborative ablation of AF. Section 13: Clinical Trial Design Overview Although there have been many advances made in the field of catheter and surgical ablation of AF, there is still much to be learned about the mechanisms of initiation and maintenance of AF and how to apply this knowledge to the still-evolving techniques of AF ablation. Although single-center, observational reports have dominated the early days of this field, we are quickly moving into an era in which hypotheses are put through the rigor of testing in well-designed, randomized, multicenter clinical trials. It is as a result of these trials that conventional thinking about the best techniques, success rates, complication rates, and long-term outcomes beyond AF recurrence—such as thromboembolism and mortality—is being put to the test. The ablation literature has also seen a proliferation of meta-analyses and other aggregate analyses, which reinforce the need for consistency in the approach to reporting the results of clinical trials. This section will review the minimum requirements for reporting on AF ablation trials. It will also acknowledge the potential limitations of using specific primary outcomes and emphasize the need for broad and consistent reporting of secondary outcomes to assist the end-user in determining not only the scientific, but also the clinical relevance of the results. Types of Clinical Trials, Strengths, and Weaknesses Mortality Trials Large, randomized, controlled multicenter trials are considered the “gold standard” for many therapies in cardiovascular medicine. They are most likely to provide an unbiased understanding of the outcomes of specific aspects of ablative intervention. Although AF is associated with increased mortality and morbidity from stroke, HF, and recurrent hospitalization, most of the AF ablation literature is focused on AF recurrence and symptomatic improvement. It remains unclear whether ablation can affect AF burden sufficiently to have a positive outcome with respect to mortality and stroke endpoints. Trials powered to demonstrate a benefit for ablation with regard to these “hard” endpoints require large numbers of patients with extensive follow-up and its accompanying expense; however, the need for such trials cannot be understated. The CABANA trial was powered to examine stroke and mortality outcomes of AF ablation compared with pharmacological rate and rhythm control strategies. CABANA, which recently completed enrollment, requires a minimum of 5 years of follow-up; thus, results will not be available until 2018. In the meantime, EAST is a study that is currently enrolling and is designed to compare standard care vs a strategy of early rhythm control with ablation and/or AADs with endpoints including a composite outcome of cardiovascular death, stroke, and hospitalization due to worsening of HF or acute coronary syndrome. Although it is unclear whether these trials will demonstrate a mortality benefit of AF ablation, both are designed to examine a host of prespecified secondary endpoints. Secondary endpoints such as HF hospitalizations are especially important for patients with uncontrolled rates and HF with preserved EF or tachycardia-induced cardiomyopathy. Finally, because both trials will include larger numbers of patient ablations with more novel technologies such as cryoablation and CFS than have been available in any other study to date, significant advances in the understanding of ablation procedure with these systems should be possible. Nevertheless, it remains imperative to continue with designs of large mortality trials that reflect shifting global ablation techniques, technologies, and patient selection. There are currently 45 trials that meet the search criteria of “ablation mortality AF” on ClinicalTrials.gov; however, fewer than 10 have mortality as part of the primary endpoint. Stroke and Thromboembolism Trials Reductions in stroke and thromboembolism remain the most important goals of AF treatment. It is unclear, however, if elimination of or reductions in AF will necessarily reduce the associated risk of stroke, and whether such outcomes exceed those possible with NOAC agents. Although an increased risk of stroke appears to be associated with brief episodes of AF detected by implanted cardiac devices, multiple large randomized trials have demonstrated that there might be no temporal relationship between AF episodes and AF thromboembolic events. This possibility has cast significant doubt regarding the direct causal role that AF plays in stroke. On the other hand, some cohort studies of AF ablation have reported a lower risk of stroke postablation compared with matched, nonablated AF populations. The impact of AF ablation on stroke and thromboembolism is an important topic of future study and will likely require a combination of very large studies with long durations of follow-up akin to CABANA and EAST. The OCEAN study is currently getting started, and will examine the optimal strategy for ongoing antithrombotic therapy 1 year after successful ablation in a moderate-risk profile population with a primary endpoint of overt and covert stroke. It is important to stress that until the results of these trials are known, the current recommendations are to continue anticoagulation indefinitely in patients with CHA2DS2-VASc ≥2, regardless of the success of the ablation procedure. Periprocedural stroke reduction is an important topic that is actively being studied, with various strategies of anticoagulation, particularly continuous administration of VKA and non-VKA oral anticoagulants through the ablation procedure. 834, 841,842 In addition, concomitant LAA occlusion is being tested. In percutaneous procedures, there are few if any studies powered for stroke alone; most primarily evaluate AF recurrence. Finally, multiple studies have demonstrated small ACE on MR brain imaging after ablation. 724,728,1207 The clinical significance of such ACE lesions is not known, and many will resolve to the point of being undetectable after weeks or months. The impact on cognitive function, if any, is not clear. At this point, there are no mandates for performing periprocedural brain imaging for novel technologies to evaluate the incidence of silent cerebral embolism, in large part because of its unknown clinical significance and the cost and burden of MRI on patients. However, further evaluation of the significance of such findings remains an important area of study. Screening substudies could be reasonable for high-risk devices and should be combined with clinical neurological and cognitive assessments. These silent cerebral emboli are to be distinguished from covert embolic strokes secondary to long-term AF, which have been linked with long-term cognitive decline, and are much larger than the silent emboli seen peri-procedurally. 1385,1386,1387,1388 Multicenter Outcome Studies There has been a proliferation of multicenter, randomized studies primarily geared toward the outcome of AF recurrence in the last several years. Many of these studies have had the appropriate size and power to make some important statements on the appropriate techniques for AF ablation. Because of the endpoint of AF recurrence, these studies can be performed with smaller sample sizes and shorter follow-up periods compared with mortality- or stroke-driven trials. A number of randomized trials have demonstrated the superiority of AF ablation over AADs in drug-refractory patients. First-line catheter ablation has shown mixed results over first-line drug therapy in the MANTRA-PAF and RAAFT-2 studies. 378,379 STAR AF 2, Adenosine Following Pulmonary Vein Isolation to Target Dormant Conduction Elimination (ADVICE), FIRE AND ICE, and TOCCASTAR are just a few examples of multicenter randomized studies that have included hundreds of patients per study and added important contributions to the daily practice of AF ablation. 245,265,378,379,489,655 STAR AF 2, for example, challenged the long-held belief that additional ablation beyond PVI is important for ablation of persistent AF and has launched a new search for alternative targets to CFAE and empiric lines. It remains possible that incomplete ablation in these arenas is more problematic than the ablation format itself. As reported recently, the FIRE AND ICE trial has shown an equivalence of evolving cryoablation technologies to traditional RF. The ADVICE trial showed that systematic use of adenosine to search for dormant conduction can improve durability of PVI and associated 1-year outcome, although studies reported earlier in this document raise questions about the overall utility of adenosine or isoproterenol. There are many more studies planned to examine various aspects of AF ablation, primarily around the comparison of techniques in certain patient populations to improve ablation outcomes. As expected, a criticism of all such trials is that the technology and techniques are outdated prior to trial completion. STAR AF 2 did not use CFS and FIRE AND ICE used a mixture of first- and second-generation CB technologies. Therefore, ongoing trials comparing the most up-to-date technologies will always be required. Larger-scale surgical ablation trials are lacking, and the consensus group believes that the development of well designed, highly agile, large-scale multicenter surgical trials with similar monitoring regimens need to be encouraged and performed. As with catheter-based studies and registries, the use of patient-reported outcome measures as part of the study endpoints is highly recommended. Industry-Sponsored Device Approval Studies There have been a number of prospective randomized studies performed to evaluate the safety and efficacy of investigational devices used for AF ablation. These studies, such as THERMOCOOL IDE and STOP AF, have all provided important, high-quality data demonstrating the superiority of catheter ablation over drug therapy in drug refractory patients. 462,684 Now that the utility of ablation over drug therapy in such patients has been accepted, many of the current studies are focused on comparing new technologies against approved devices in a noninferiority design. Although these studies are important from a safety and efficacy perspective and are often mandated by health approval bodies such as the FDA, the incremental yield in knowledge could be limited. Prespecified subgroup analyses, or the use of novel endpoints. could therefore be important to determine whether incremental value is added by the newer technology. TOCCASTAR, for example, demonstrated statistical noninferiority of CF-driven RF ablation to traditional RF. However, only in a post-hoc analysis did the trial show that optimal CF was associated with better outcomes, findings which should be viewed with caution due to the limitations of post hoc analyses. Testing of the durability of lesion sets such as PVI either after delayed waiting, drug (adenosine) challenge, or repeat electrophysiology study after 3 months might also help assess comparative efficacy more accurately. Industry must also look to see whether safety and efficacy parameters demonstrated in PAF also apply to nonparoxysmal populations. Several industry-sponsored studies are either being planned or are in progress to assess outcomes in this challenging population. Registry Studies AF ablation registries offer a unique opportunity to collect data from large numbers of patients to examine outcomes. In particular, registries might help assess how ablation is being performed in the “real world” compared with controlled clinical trials that are often performed on a highly selected patient population in very experienced centers. The Definition of real world remains problematic, however, because recent studies have shown reasonable congruence between the outcomes of RCTs and registries. Registries are well suited to determining early complication rates of ablation, particularly for less common ones such as PV stenosis, esophageal injury, or mortality. Appropriateness of patient selection and outcomes in patient subgroups that are underrepresented in studies, such as women or patients with underlying structural heart disease, can also be assessed in sizable registries. The collection of this kind of information, by itself, makes registries worthwhile if they can be performed with sufficient representation of a majority of centers. Still, well-controlled efforts such as the STS database have shown an evenhanded approach to collecting this kind of material. Worldwide surveys of AF ablation have been published, and ongoing efforts are being made to harmonize various centers or national databases to pool ablation information. Many countries are now setting up provincial or national registries to examine the use and outcomes of AF ablation. In the United States, for example, the older Safety of Atrial Fibrillation Ablation Registry Initiative registry project was discontinued, but another started by the National Cardiovascular Data Registry (NCDR) has been launched nationally, with voluntary participation. The HRS is also collaborating with the AHA to develop an additional AF ablation registry. Surgical data are currently being collected in the STS database; however, although data on safety and outcome are available, lesion-specific information for surgical ablation remains preliminary. Collection of longitudinal data, particularly longer-term outcomes, can be limited by a lack of patient follow-up at the same center and a lack of consistent monitoring protocols. The need for informed consent to collect follow-up data also remains an obstacle to obtaining outcome data. The burden of data entry can also lead to inadequate reporting, and the cost of auditing data can be very expensive and tedious. The purpose of establishing a registry and the realistic goals of data collection must be stated outright upon establishment, because the opportunity and financial costs could be alternatively spent on well-designed clinical trials. Comparison of performance among sites, for example, must be based on the stated purposes and strengths of the registry. If the main purpose is to report acute complications, then long-term outcomes cannot be compared. Comparisons must also be corrected for patient characteristics, referral patterns to the institution, and community-based versus advanced academic practices. Finally, once the stated goals of the registry are accomplished, there should be specific timeframes for termination of the registry to avoid indefinite data collection with no specific stated purpose. Clinical Endpoint Considerations Early data in the field of AF ablation were limited by the multitude of different endpoints used in the trials, including multiple definitions of success, complications, and minimum monitoring postablation. Prior consensus statements sought to create consistency in the reporting of clinical trials by adopting standardized definitions for AF type, blanking periods, definitions of success, recommendations for minimal monitoring postablation, major complications, and device-related complications. 1,2 Again, this document outlines the definitions of various types of AF (Table 1), definitions of efficacy (Table 10), QOL measures (Table 11), non-AF recurrence endpoints (Table 12), and definitions of complications (Table 8). Clinical endpoints for AF ablation trials may either consist of clinical events like mortality, stroke, re-initiation of AAD treatment, need for cardioversion, reablation and rehospitalization, or of patient-reported outcomes such as symptom severity or QOL. AF recurrence or change in AF behavior is a very important endpoint to report in trials targeting AF elimination. The following section will focus on recommendations and definitions for AF-related measurements used in clinical ablation trials. Blanking Period It has long been recognized that in the weeks immediately following AF ablation, early recurrences of atrial arrhythmia can occur that subsequently subside over time. 253,254,255,436 Whether this is due to an early “inflammatory” response in the atrium or pericardium remains hypothetical. Based on these observations, prior consensus statements, and the present consensus document, the writing group recommends the use of a 3-month blanking period immediately postablation, during which arrhythmia recurrences are not counted toward the primary recurrence endpoint (Table 10). The use of a blanking period is not without limitations. Although half of all early recurrences might subside, early recurrence remains a very significant predictor of late recurrence of AF. 141,142,143,255 Furthermore, some studies have shown that recurrences occurring early in the blanking period (within 1–2 months) are less predictive of late recurrence, whereas those occurring in the third month have a very high predictive value for later recurrence. 933,977,1389 Blanking periods can also be applied inconsistently, typically after the initial ablation, but not typically after repeat procedures, particularly when there is only a limited duration of follow-up. Despite these limitations, the writing group consensus continues to recommend the use of a 3-month blanking period for atrial arrhythmia recurrences post-initial ablation for AF. If alternate durations of blanking are employed, they should be prespecified in the trial methodology. Clinical trials should also consider routine discontinuation of AADs after the blanking period to determine off-drug success rates of ablation. Large clinical trials such as CABANA have also employed extensive ongoing monitoring, which could shed light on more robust blanking period definitions. The currently recommended definitions of the blanking periods, monitoring standards, complications, and other AF ablation clinical trial definitions are provided in Tables 8 and 10. AF Recurrence Endpoints The selection of a primary endpoint depends on the objectives of the trial. As mentioned earlier in this section, trials with mortality, stroke, or hospitalization outcomes are of particular interest in advancing the field of AF ablation. However, now and in the foreseeable future, recurrence of AF will remain of primary interest for most clinical trials. A summary of AF-related endpoints is listed in Table 13, along with the advantages and disadvantages of each endpoint. The consensus statement reaffirms the use of freedom from any atrial arrhythmia (e.g., AF, AT, or AFL) greater than 30 seconds off antiarrhythmic therapy as the gold standard for reporting the efficacy of AF ablation (Table 10). The writing group also believes that all trials should report single-procedure, off AAD therapy efficacy for ablation with a minimum of 12 months follow-up. Slight variations in this endpoint have been used in several clinical trials, but ideally, all categories of recurrence should be reported transparently, such as freedom from AF separately from other atrial arrhythmia, one- and multiple-procedure success rates, and success on and off antiarrhythmic therapy. By reporting all of these variations, the reader can determine the most relevant outcome for themselves and can also easily compare results between clinical trials. A recent study that reported outcomes using a wide variety of endpoints can serve as an excellent example of this approach to reporting outcomes. 245 The inclusion of all atrial arrhythmias compared with AF in isolation recognizes the fact that ablation can result in iatrogenic macro- and microreentrant tachycardias caused by incomplete scar formation from the procedure itself. Furthermore, patients might present with mixed pictures of both AFL and fibrillation, and elimination of one but not the other will not improve patient outcomes. The consensus statement recognizes that the 30-second cutoff for arrhythmia recurrence is stringent and might not accurately reflect more clinically relevant endpoints, such as reduction in total AF burden, symptom abatement, and improvement in QOL. A strict cutoff might also underestimate the true benefit of ablation, especially when presented in the format of a Kaplan-Meier analysis. Isolated, brief recurrences can result in a patient being considered a “procedural failure,” although the overall reduction in AF burden has been substantial. Patients with preablation high-burden PAF might continue to experience AF episodes, but with a reduced frequency and duration and a significant improvement in QOL. More liberal cutoff points have been suggested based on implantable monitoring technology detection limits (>2 minutes) or based on hypothesized thresholds for stroke risk (>6 minutes or >5–6 hours). However, selection of any other cutoff would be as arbitrary as the initial selection of 30 seconds, which has now been in place since 2007. Keeping the same endpoint threshold will therefore allow for comparison of future studies against those performed in the past. It also remains unclear whether the selection of a somewhat more generous threshold would actually significantly alter reported success rates in a time to event analysis. Arrhythmia recurrence is often reported as time to first AF episode of a particular type, such as any episode of an ATA lasting more than 30 seconds, verified by surface ECG (loop recorder) or an intracardiac electrogram. This parameter might best reflect differences in lesion quality around PVs for electrical isolation. Ineffective ablation and early gap formation could result in an earlier time to first recurrent AF. Even the time to the second or third AF recurrence might further allow insights into such ablation effects and could therefore be used as a secondary outcome measurement. Cutoffs of more than 30 seconds can be reported in addition to the 30-second primary endpoint to show how procedural success might change. In fact, the consensus group encourages such reporting routinely in all clinical trials to better assess the most clinically relevant outcomes for future clinical trials. In particular, higher cutoffs can be used for patients with persistent or long-standing persistent AF because of the very high burden of preablation AF and the lower likelihood that ablation will result in a full “cure” of the arrhythmia. It is strongly suggested that other cutoffs be pre-specified and reported in secondary outcomes of trials so the true effects of catheter ablation on various types of AF can be put into proper context outside of the 30-second cutoff. A cutoff that can be used in addition to 30 seconds would be the time to first clinical or stroke-relevant AF duration (e.g., more than 1 hour or 5.5 hours). As already described, the SOS trial revealed AF activity of more than 1 hour per day as a cutoff for an increased risk of stroke, whereas other investigation revealed various AF burden levels, such as a marker of an increased risk for thromboembolism. This parameter might be used preferentially in studies in which the potential of ablation to reduce outcomes such as thromboembolism might be the primary interest. “Time to first persistent AF” could be considered for trials of persistent AF ablation in which time to the first episode of more than 7 days might be a relevant parameter while investigating substrate modifying ablation therapies such as atrial lines or localized rotational activity elimination. AF Burden Endpoints Rather than report time to an AF recurrence of a specific duration, many feel that AF burden is a more optimal endpoint for assessing ablation efficacy. AF burden can be estimated based on serial long-term monitoring results and patient symptom reporting, but only continuous monitoring through a cardiac implantable electronic device (loop, pacemaker, ICD) can truly define the burden. Furthermore, placement of such an implantable recording device should ideally be performed preablation so that pre- and postablation outcomes can be compared. Use of such devices, however, can be quite costly and impose undue difficulty in performing clinical trials. AF burden can be used in various ways in AF ablation trials. Freedom from relevant AF—classically defined as an absence of any ATA of more than 30 seconds—might be defined, for example, as a low daily AF burden less than 1%–2%. This approach would recognize the fact that occasional and short-lasting atrial arrhythmias over a few minutes might be an acceptable outcome. It should be noted, however, that there is a substantial difference between long-term, daily monitoring of AF burden versus a detection period of 3 months, as in the Asymptomatic Atrial Fibrillation and Stroke Evaluation in Pacemaker Patients and the Atrial Fibrillation Reduction Atrial Pacing Trial, in which short-lasting AF was likely a marker for future long-lasting AF outside the monitoring period. 1390 Reduction in AF burden more than 75% could be considered as clinical success just as much as reduction in both the number and duration of AF episodes. However, the number and duration of episodes are significantly more sensitive to under- or oversensing with subcutaneous devices but also implanted pacemakers or defibrillators for various technical reasons. In contrast, the number of episodes necessitating urgent or emergency care visits might not only be clinically relevant, but might also help demonstrate the cost-effectiveness of the procedure. Furthermore, because there is no firm scientific basis for selecting the cutoff of 75%, this prior recommendation is provided only as an example of what future clinical trials might choose to use as a Definition of clinical or partial success. In recognition that AF ablation may not be curative, particularly for patients with persistent or long-standing persistent AF, the concepts of AF progression and regression, while unproven, could be of interest. Many patients might initially present with very infrequent episodes of PAF that could be quite manageable with minimal drug therapy. Ablation in this setting might help delay progression to higher burden paroxysmal or persistent AF, which could be associated with decreased functioning but also increased risks of stroke, HF, or death. On the other hand, patients with persistent AF who can be converted into infrequent, paroxysmal forms of AF (so-called AF regression) might experience not only QOL benefits but also a potential reduction in morbidity and mortality. In order for these endpoints to be widely implemented, thresholds of AF must be established under which patient QOL and risk of adverse outcomes are reliably improved, which has yet to be done. For example, one substudy of the STAR AF 1 trial showed that patients with very high-burden paroxysmal or persistent AF could continue to experience up to 2 or more hours of AF per month postablation and still report an improvement in QOL. 1391 The patient-reported symptoms did not deteriorate until they experienced more than 27 hours of AF per month. This outcome remains an important focus for ongoing clinical investigation. When an implanted device is not used, many trials have attempted to estimate changes in AF burden by using various methods. If careful recording of patient symptoms and clinically apparent recurrences is performed, including duration and frequency of episodes over a specific period of time, then these could be used to estimate AF burden pre- and postablation. 1391 Total AF detected on intermittent continuous monitoring (like intermittent 7 day Holters) could be used, although the accuracy is somewhat limited depending on the duration and frequency of monitoring. 378 Intermittent, but frequent, transtelephonic or other portable monitors can provide brief strips of rhythm status. Time in sinus rhythm could be estimated by the number of weeks (for example), with sinus transmissions divided by the total number of weeks of the monitoring period, akin to a time in therapeutic range for OAC with VKA. 245 A combination of symptom reporting and ECG status at various time points can also be used to calculate estimated time in sinus rhythm, as was employed in a substudy of the Atrial Fibrillation and Congestive Heart Failure study. 1392 Endpoint Differences for Paroxysmal vs Nonparoxysmal AF Ablation Studies Important consideration should be given to differences in AF recurrence endpoint reporting in trials of paroxysmal versus persistent AF. For patients with PAF, the burden might not be well suited for determining the outcome of ablation. Because the preablation burden can be relatively low in the months preceding ablation, with a large range in the burden, it might be hard to realize a statistically significant change postablation or between treatment arms. This was demonstrated in the MANTRA-PAF trial, in which total AF burden (measured on 7-day Holters) did not differ between drug and ablation therapy, but the total number of patients free from any AF recurrence was significantly higher in the ablation arm. 378 For these patients, a time to recurrence or proportion free from arrhythmia endpoint might be a better option. Other statistical concerns that need to be considered for AF burden as an outcome measure for ablation in PAF patients include regression to the mean and the clustered, nonrandom pattern of PAF episodes. For persistent AF, reduction in burden can be much more relevant because the preablation burden will be high (close to 100%), with little standard deviation, making a statistical reduction postablation easier to define. On the other hand, the use of freedom from 30-second endpoints could underestimate the true clinical effect of ablation in the persistent population. The consensus group still maintains that the 30-second endpoint should be reported, but secondary endpoints such as changes in AF burden and/or AF progression or regression should also be described. Both CABANA and EAST, with more extensive monitoring, should both shed additional light on these issues. The writing group members encourage reporting of other secondary endpoints that might better represent clinically relevant outcomes of the ablation procedure. Improvements in patient QOL are very important to assessing the clinical success of AF ablation, but as with any intervention, the magnitude of the improvements might be confounded by expectancy bias (“placebo effect”). A detailed discussion of QOL measurements and potential benefits and limitations appears later in this section. Symptomatic vs Asymptomatic Recurrence Even in patients with highly symptomatic AF, as many as half of all episodes can occur without associated symptoms. 56 The ratio of asymptomatic to symptomatic episodes increases up to 4-fold postablation, perhaps due to shorter durations, slower rates, or autonomic modulation after the procedure. 58 In highly symptomatic AF patients, asymptomatic episodes often coexist with the symptomatic; thus, patient reporting of symptoms can still serve as a rough surrogate for procedural success. For clinical trial purposes, however, reporting of only symptomatic AF recurrences could overestimate procedural success by 20% or more by missing asymptomatic recurrences. The importance of asymptomatic AF detection depends in part on the purpose of the clinical trial. If patient QOL and symptom abatement is the primary goal of therapy in the study, then underdetection of asymptomatic AF could be of little relevance. However, if the study goal is to reduce the associated risks of AF (stroke, HF) and to change potential therapy, including OAC, then the detection of asymptomatic AF is much more critical. Typically, the detection of asymptomatic AF recurrence is accomplished by longer-term, frequent, or implantable monitoring approaches. AF Monitoring Postablation Arrhythmia monitoring can be performed with the use of noncontinuous or continuous ECG monitoring tools. The choice of either method depends on individual need and consequence of arrhythmia detection. Basically, more intensive monitoring is associated with a greater likelihood of detecting both symptomatic and asymptomatic AF. 56,58,937 identification of patients with AF and assessment of AF burden with intermittent monitoring have been shown to depend on a patient’s actual AF burden, and improve with an increasing frequency or duration of intermittent monitoring. Conversely, the more complex and longer the method of monitoring that is used, the lower the patient compliance. Available noncontinuous detection tools include scheduled or symptom-initiated standard ECGs, Holter (24 hours to 7 days), transtelephonic recordings, patient- and automatically activated devices, and external loop recorders (Table 6). Scheduled 7-day Holter ECG recordings or daily plus symptom-activated event recordings are estimated to document approximately 70% of AF recurrences, with an estimated negative predictive value for absence of AF between 25% and 40%. 947,1393 Continuous ECG monitoring is permanent monitoring for a long time period (1, 2, or more years). Continuous ECG monitoring can be facilitated with the use of implantable devices. Implantable pacemakers or defibrillators with atrial leads allow the burden of AF to be assessed by tracking the number and duration of mode switch episodes, particularly when an arrhythmia duration of ≥5 minutes is used as the cutoff value. 1394 More recently, a long-term subcutaneous implantable loop monitor has become available to facilitate continuous AF monitoring based on R-R interval analysis over a period of 2 years. 58,952 These types of continuous ECG monitoring devices can be used to evaluate the results of AF ablation. Although implantable subcutaneous monitors hold promise for determination of AF burden long term, important limitations include less than 100% specificity due to myopotentials, atrial and ventricular premature beats, as well as limited memory resulting in electrograms not being retrievable to verify the correct rhythm diagnosis. Another major limitation for the performance of clinical trials is cost. If the consensus mandated ILR monitoring for all clinical trials, the cost of performing such trials would likely become prohibitive. There are also a number of patients who might refuse long-term devices. Again, the purpose of the trial should be married to the type of monitoring performed. If the ultimate goal is to improve patients’ QOL, then excessive monitoring for asymptomatic AF might not be worth the effort. However, if the goal is to reduce AF burden, or change prognosis, particularly from a stroke point of view, then continuous monitoring should be required. In the past, the consensus statement has provided minimum clinical requirements for postablation monitoring for clinical trials. Initially, these were quite stringent, and in the last consensus statement, the requirements were made more flexible. The current consensus recommends the following minimum monitoring requirements: For PAF, follow-up screening should include a minimum of three visits (e.g., at 3, 6, and 12 months), with a 12-lead ECG at each visit, a 24-hour Holter at the end of the follow-up period (e.g., 12 months), and more limited event recording from the end of the 3-month blanking period to the end of follow-up (e.g., 12 months), both at regular periods and with patient activated recordings obtained at the time of symptoms (or equivalent). Follow-up beyond 1 year is encouraged and might occur every 6 months with Holter and ECG (or equivalent). For persistent and long-standing persistent AF, follow-up screening should include a minimum of three visits (e.g., at 3, 6, and 12 months), with a 12-lead ECG at each visit, a 24-hour Holter every 6 months, and event recording from the end of the 3-month blanking period to the end of follow-up (e.g., 12 months), as well as at the time of symptoms (or equivalent). Follow-up beyond 1 year is encouraged and might occur every 6 months with Holter and ECG (or equivalent) (Table 10). In making these recommendations, it is important to recognize that the writing group views these as minimal monitoring recommendations. More intensive follow-up with more frequent Holters and/or extended ECG monitoring is encouraged. Similarly, follow-up beyond 1 year is encouraged and might occur every 6 months with Holter and ECG (or equivalent). It is acknowledged that this recommendation falls short of continuous monitoring and will largely detect symptomatic recurrences with only a limited ability to detect asymptomatic recurrences. However, this minimum standard will at least provide some consistency in trial reporting, and trials are encouraged to exceed this standard where possible. Details are specified in Table 10. QOL Measurement QOL should remain an important endpoint for AF ablation studies, but not necessarily the primary endpoint. QOL is limited by treatment expectancy bias. Although sham procedures have not been performed to assess the true magnitude of this bias, it is unlikely that such studies will be performed because they would be extremely challenging. QOL can be measured both using well-established scales like the SF-36 and EQ5D, but also using more specific scales like the Atrial Fibrillation Effect on QualiTy-of-Life (AFEQT), University of Toronto Atrial Fibrillation Severity Scale, Mayo AF-Specific Symptom Inventory, or Symptom Severity Score. The advantages of the generalized scales is their wide usage in medicine, the ability to compare improvements in QOL with other medical interventions, and in the case of the EQ5D, converts QOL changes to cost-effectiveness measures through the use of QALYs; however, these scales can lack sensitivity to changes with reductions in AF burden. AF-specific scales, on the other hand, might improve sensitivity and discriminate more effectively between patients with successful and failed ablation. At present, the true value of AF-specific scales requires validation through randomized studies using standard of care therapy as a control arm, given the comorbidity associated with AF can impact the same symptoms that affect the EHRA score and the Canadian Cardiovascular Society Severity in Atrial Fibrillation scale. Finally, we still need to know how these changes compare with other medical interventions and if the changes would result in substantial reductions in health care cost or patient morbidity. The consensus group recommends that all clinical trials incorporate some measure of patient-reported outcomes and preferably measure them using both a general and an AF-specific measurement scale. A summary of QOL scales is provided in Table 11. Other Endpoint Reporting There are important subgroups of patients and clinical outcomes that need to be studied, but are unlikely to be addressed by any one study alone. To facilitate pooled data analysis, the consensus recommends routine reporting of additional subgroup analyses, particularly around modifiable lifestyle risk factors. BMI and OSA should be reported in the baseline characteristics and subgroup analysis, comparing high vs average BMI and those with and without sleep apnea, which should be ideally reported in recognition that modifiable risk factors are an important contributor to AF progression and ablation outcome. The need for a better understanding of the most appropriate postablation anticoagulation strategy is particularly recognized by the consensus group. Due to the rarity of stroke, TIA, and peripheral thromboembolism, it is unlikely that sufficiently powered studies will ever be conducted to conclusively resolve this relevant aspect of clinical practice. In the absence of a clear strategy, it is possible that postablation patients are exposed to an excess stroke risk if untreated, or to an excess bleeding risk if treated with no real need. As a reasonable surrogate to an evidence-based demonstration, the consensus group recognizes the value of careful reporting of secondary outcomes in which individual data are made available for (1) baseline risk factors; (2) postablation anticoagulation strategy (e.g., if continued, and if so, which drug, or discontinued); and (3) postablation thromboembolic and/or bleeding events. An effort of this type would not only enhance the quality of the single studies, but it would also allow for pooled analyses in the future. Examples of specific secondary outcomes that could be reported are summarized in Tables 10 and 12. Unanswered Questions in AF Ablation There is still much to be learned about the mechanisms of AF, techniques of AF ablation, and long-term outcomes. The following are unanswered questions for future investigation: AF ablation and modification of stroke risk and need for ongoing OAC: The CHA2DS2-VASc score was developed for patients with clinical AF. If a patient has received a successful ablation such that he/she no longer has clinical AF (subclinical, or no AF), then what is the need for ongoing OAC? Are there any patients in whom successful ablation could lead to discontinuation of OAC? Substrate modification in catheter-based management of AF—particularly for persistent AF: What is the proper lesion set required beyond PVI? Do lines and CFAE have any remaining role? Are these approaches ill-advised or simply discouraged? What is the role of targeting localized rotational activations? How do we ablate a localized rotational activation? How can scar be characterized and targeted for ablation? Do we need to replicate the MAZE procedure? Does the RA need to be targeted as well as the LA? Autonomic influence in AF: Is clinical AF really an autonomic mediated arrhythmia? Is elimination of GP required? Is there a role for autonomic modulation, for example, spinal cord or vagal stimulation? Contribution and modulation of risk factors on outcomes of AF ablation: Obesity reduction has been shown to reduce AF burden and recurrence in patients undergoing ablation. What is the role of bariatric surgery? Does the modulation of other risk factors influence outcome such as hypertension, sleep apnea, and diabetes? Outcomes in ablation of high-risk populations: Do high-risk populations benefit from AF ablation? Congestive HF has been assessed in smaller trials, but larger trials are required. Outcome data are needed in patients with very enlarged LAs, HCM, patients with renal failure on dialysis, and the very elderly. Surgical vs catheter-based vs hybrid ablation: There should be more comparative work between percutaneous and minimally invasive surgical approaches. Both report similar outcomes, but there is a dearth of comparative data. Is there any patient benefitany patient benefitny patient benefit to hybrid procedures? How do we characterize patients who are optimal candidates for ablation? Preablation LGE-MRI might identify patients with heavy burdens of scar who are unlikely to respond to ablation. These techniques must become reproducible and reliable and must be assessed in multicenter trials. Other markers need to be investigated, including genetic markers, biochemical markers, and clinical markers based on aggregated risk scores. The incremental role of new technologies: As newer and often more expensive technologies are produced for AF ablation, their definitive incremental value must be determined in order to justify change in practice or case cost. These technologies include global (basket) mapping techniques, newer ablation indices for assessing lesion durability, advanced imaging for viewing lesions in the myocardium, etc. New energy sources, including laser, low-intensity ultrasound, photonic particle therapy, external beam ablation, and MRI-guided ablation, must be assessed in comparative fashion. Outcomes of AF ablation: We need to better understand the clinical relevance of ablation outcomes. What is the significance of time to recurrence of 30 seconds of arrhythmia? How do we best quantify AF burden? How do these outcomes relate to QOL and stroke risk? What is the role of surgical LA reduction? Does LAA occlusion or obliteration improve outcome of persistent AF ablation with an accompanying reduction in stroke? Does ablation work through atrial size reduction? What is the incidence of “stiff atrial” syndrome and does this mitigate the clinical impact of ablation? Working in teams: What is the role of the entire heart team in AF ablation? Does a team approach achieve better outcomes than a “silo” approach? Improving the safety of catheter ablation: As ablation extends to more operators and less experienced operators, the statistical occurrence of complications will increase. We need newer techniques to minimize complications and institute standards for operators to improve the reproducibility of ablation results and safety profiles at a variety of centers worldwide. How does catheter ablation affect mortality, stroke, and hospitalization in broad and selected patient populations receiving catheter ablation for AF? Management of patients who fail initial attempts at catheter ablation: Should there be specific criteria for repeat ablations (e.g., atrial size, BMI)? Should patients be referred for surgery for repeat ablation? In order to address these and other important questions in the field of catheter and surgical AF ablation, we urge investigators to create and participate in multisite collaborations and electrophysiology research networks with involvement of senior and junior investigators on the steering committees to push forward the next phase of AF research. We also urge funding bodies to support these important initiatives. Section 14: Conclusion Catheter ablation of AF is a very commonly performed procedure in hospitals throughout the world. Surgical ablation of AF, although less widely available than catheter-based AF ablation, is also an important therapeutic option for patients with AF at many major medical centers. This document provides an up-to-date review of the indications, techniques, and outcomes of catheter and surgical ablation of AF. Areas for which a consensus can be reached concerning AF ablation are identified, and a series of consensus definitions have been developed for use in future clinical trials of AF ablation. Also included within this document are recommendations concerning indications for AF ablation, technical performance of this procedure, and training. It is our hope to improve patient care by providing a foundation for those involved with care of patients with AF as well as those who perform AF ablation. It is recognized that this field continues to evolve rapidly and that this document will need to be updated. Successful AF ablation programs optimally should consist of a cooperative team of cardiologists, electrophysiologists, and surgeons to ensure appropriate indications, procedure selection, and follow-up.