7
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Feasibility and analysis of bipolar concentric recording of electrohysterogram with flexible active electrode.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The conduction velocity and propagation patterns of the electrohysterogram (EHG) provide fundamental information on the electrophysiological condition of the uterus. However, the accuracy of these measurements can be impaired by both the poor spatial selectivity and sensitivity to the relative direction of the contraction propagation associated with conventional disc electrodes. Concentric ring electrodes could overcome these limitations. The aim of this study was to examine the feasibility of picking up surface EHG signals using a new flexible tripolar concentric ring electrode (TCRE), and to compare these signals with conventional bipolar recordings. Simultaneous recording of conventional bipolar signals and bipolar concentric EHG (BC-EHG) were carried out on 22 pregnant women. Signal bursts were characterized and compared. No significant differences were found between the channels in either duration or dominant frequency in the Fast Wave High frequency range. Nonetheless, the high pass filtering effect of the BC-EHG recordings gave lower frequency content between 0.1 and 0.2 Hz. Although the BC-EHG signal amplitude was about 5-7 times smaller than that of bipolar recordings, a similar signal-to-noise ratio was obtained. These results suggest that the flexible TCRE is able to pick up uterine electrical activity and could provide additional information for deducing the uterine electrophysiological condition.

          Related collections

          Author and article information

          Journal
          Ann Biomed Eng
          Annals of biomedical engineering
          1573-9686
          0090-6964
          Apr 2015
          : 43
          : 4
          Affiliations
          [1 ] Institute of Research and Innovation in Bioengineering, Universidad Politécnica de Valencia, Camino de Vera s/n Ed.7F, 46022, Valencia, Spain, yiye@gbio.i3bh.es.
          Article
          10.1007/s10439-014-1130-5
          25274161
          0578b379-28e4-42e7-bfe4-b6cedcb503f6
          History

          Comments