4
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Translated title: Critical aortic stenosis in the neonate. Clinical assessment and surgical outcome in 18 patients

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          OBJECTIVE - To assess neonates with aortic stenosis with early decompensation operated upon. (LCO) (CHF). METHODS - A and retrospective study analyzing 6 neonates with LCO, group I (GI), and 12 neonates with CHF, group II (GII). Clinical radiographic, electrocardiographic and echocardiographic findings also provided comparative bases for the study, as did surgical and evolutional findings. RESULTS - The mean ages at hospitalization and surgery (p = 0.0031) were 14.3 and 14.8 days in GI and 35.4 and 42.8 days in GII, respectively. Cardiac murmurs were more intense in GII (p = 0.0220). The aortic ring was smaller in GI (8.0 ± 2.5mm) as compared to GII (11.4±1.4mm) (p = 0.2882). Ventricular function was reduced to 18±5.5% and 33.3±7.6% in GI and GII, respectively (p = 0.0162). Aortic atresia, however, was present only in 2 neonates in GI. Five of 6 patients in GI died but all patients in GII survived (p=0.0007). In the latter group, 84.6% of the patients were in functional class I (FC-I) in the long-term follow-up, with moderate residual lesions in 6 neonates, discrete residual lesions in 4, and reoperation in 2. CONCLUSION - Aortic stenosis is a severe anomaly of the neonate, whose immediate evolution depends on the pre-operative anatomic and functional findings, and the late evolution essentially depends on the anatomic features of the valve.

          Related collections

          Most cited references14

          • Record: found
          • Abstract: found
          • Article: not found

          Percutaneous balloon aortic valvuloplasty: results in 23 patients.

          Percutaneous balloon aortic valvuloplasty (BAV) was performed in 23 consecutive patients with valvular aortic stenosis with no associated cardiac defects. The patients were 2 to 17 years old and were referred from 12 hospitals in 4 states. The balloon was positioned across the aortic valve and inflated to pressures of 80, 100, then 120 psi. Each inflation lasted 5 to 10 seconds. The arterial and venous catheters were connected together outside the groin to avoid excessive increase in left ventricular pressure during total aortic valve occlusion with the inflated balloon. Peak systolic aortic valve pressure gradient and cardiac output were measured before and 15 minutes after BAV. There was no significant change in cardiac output, but all patients had a lessened gradient. The gradient before BAV was 113 +/- 48 mm Hg, decreasing to 32 +/- 15 mm Hg after BAV (p less than 0.01). The left ventricular peak systolic pressure decreased from 221 +/- 54 to 149 +/- 21 mm Hg (p less than 0.01). No aortic regurgitation was noted in 13 patients and very mild aortic regurgitation was noted in 10 patients after BAV. The balloons were 10 to 20 mm in diameter, chosen at least 1 mm smaller than the diameter of the aortic valve anulus. Pressures of 100 to 120 psi were required to achieve full inflation of the balloons. Six patients had repeat cardiac catheterization studies 3 to 9 months after BAV. In none was there a significant change in peak systolic aortic valve pressure gradient or cardiac output compared with the study immediately after valvuloplasty.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Predictors of survival in neonates with critical aortic stenosis.

            Failure of infants with critical aortic stenosis to survive after adequate valvotomy despite a left ventricular size that appears to be adequate indicates that additional preoperative anatomic features may contribute to mortality.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Contemporary results of balloon valvuloplasty and surgical valvotomy for congenital aortic stenosis.

              The purpose of this study was to compare contemporary results of balloon dilatation and surgery for valvar aortic stenosis in infants and children in the five years between August 1988 and October 1993. Thirty four children underwent attempted balloon valvuloplasty (age 1 day-16 years, weight 1720 g-68 kg) (group 1), eight of whom were neonates with critical aortic stenosis. During the same period, 17 children underwent direct surgical valvotomy (group 2) (seven neonates). Successful balloon valvuloplasty was achieved in 33 (97%) with immediate reduction in the instantaneous systolic pressure gradient from 82 to 34 mm Hg (mean). There were two deaths in this group (both neonates), the second in a preterm neonate from necrotising enterocolitis. Complications requiring intervention in group 1 were aortic regurgitation in one and femoral artery injury in two. Follow up from four months to five years showed sustained results in most cases. There were two neonatal deaths in the surgical group. When the two groups were compared there was no significant difference in mortality, morbidity, or need for reintervention within 12 months. Deaths from both groups were attributed to small left ventricles. Hospital stay was significantly shorter in group 1. It is concluded that balloon dilatation for valvar aortic stenosis is effective and safe for the entire paediatric population. The results compare favourably with those of surgery.
                Bookmark

                Author and article information

                Journal
                abc
                Arquivos Brasileiros de Cardiologia
                Arq. Bras. Cardiol.
                Sociedade Brasileira de Cardiologia - SBC (São Paulo, SP, Brazil )
                0066-782X
                1678-4170
                October 1999
                : 73
                : 4
                : 354-358
                Affiliations
                [01] São Paulo SP orgnameUniversidade de São Paulo orgdiv1Faculdade de Medicina orgdiv2Hospital das Clínicas
                Article
                S0066-782X1999001000003 S0066-782X(99)07300403
                04b5ac0d-f1f6-4f74-86a3-64e016a871c0

                This work is licensed under a Creative Commons Attribution 4.0 International License.

                History
                Page count
                Figures: 0, Tables: 0, Equations: 0, References: 14, Pages: 5
                Product

                SciELO Brazil

                Categories
                Original Articles

                aortic stenosis,surgery,congenital heart disease,neonate

                Comments

                Comment on this article