      Graphene quantum dots/gold electrode and its application in living cell H2O2 detection.

      Read this article at

      ScienceOpenPublisherPubMed
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Due to the high peroxidase-like activity and small lateral size of graphene quantum dots (GQDs), the covalently assembled GQDs/Au electrode exhibits great performance and stability in H(2)O(2) detection. It is better or comparable to some enzyme-immobilized electrodes, and thus could be useful in sensing H(2)O(2) changes in biological systems.