      Comparison of Anterior Chamber Depth Measurements from the Galilei Dual Scheimpflug Analyzer with IOLMaster

      other
      1 , 1, 2 , *
      Journal of Ophthalmology
      Hindawi Publishing Corporation

      Read this article at

          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose. To compare anterior chamber depth (ACD), representing the distance between the anterior corneal surface and anterior lens surface measurements between the Galilei Dual Scheimpflug Analyzer and the IOLMaster. Methods. A retrospective review of 65 individual patient eyes with normal anterior segments, and no prior ocular surgery was performed. Patients underwent ACD measurements with both devices during the same session by a trained examiner. Interdevice agreement was evaluated using paired two-tailed t-tests, Pearson correlation coefficient, and Bland-Altman analysis. Results. The mean ± standard deviation (SD) ACD for the Galilei and IOLMaster was 3.37 ± 0.36 mm (range from 2.62 to 4.13) and 3.25 ± 0.38 mm (range from 2.34 to 3.92), respectively (Pearson correlation coefficient = 0.96). ACD mean difference was 0.12 mm ( P < 0.0001); 95% limits of agreement was from −0.09 to 0.34. The Galilei measured slightly longer ACD values than the IOLMaster. There was no relationship between axial length and interdevice difference. Conclusion. ACD measurements correlate well between the Galilei and IOLMaster, with Galilei values on average 0.12 mm longer than the IOLMaster.

          Related collections

          Most cited references19

          • Record: found
          • Abstract: not found
          • Article: not found

          A three-part system for refining intraocular lens power calculations

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            A three-part system for refining intraocular lens power calculations.

            A three-part system that determines the correct power for an intraocular lens (IOL) to achieve a desired postoperative refraction is presented. The three components are (1) data screening criteria to identify improbable axial length and keratometry measurements, (2) a new IOL calculation formula that exceeds the current accuracy of other formulas for short, medium, and long eyes, and (3) a personalized "surgeon factor" that adjusts for any consistent bias in the surgeon's results, from any source, based on a reverse solution of the new formula; the reverse solution uses the postoperative stabilized refraction, the dioptric power of the implanted IOL, and the preoperative corneal and axial length measurements to calculate the personalized surgeon factor. The improved accuracy of the new formula was proven by performing IOL power calculations on 2,000 eyes from 12 surgeons and comparing the results to seven other currently used formulas.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Prediction of the effective postoperative (intraocular lens) anterior chamber depth.

              To investigate methods to predict the effective postoperative anterior chamber depth (ACD) based on a large patient sample. University Eye Clinic, Aarhus Kommunehospital, Aarhus, Denmark. Based on 6698 consecutive cataract operations with recorded postoperative refractive results, the postoperative effective ACD was calculated in each case and studied by multiple linear regression for covariance with a number of preoperatively defined variables including the axial length by ultrasonography, preoperative ACD, lens thickness, corneal radius by keratometry, subjective refraction, patient age, and corneal white-to-white diameter, the latter of which was available in a subgroup of 900 cases. The postoperative effective ACD was significantly correlated with 6 preoperative variables (in decreasing order): axial length, preoperative ACD, keratometry reading, lens thickness, refraction, and patient age (R = 0.49, P < .000001). Age showed the weakest correlation (P = .02) and could be omitted with no significant decrease in the total correlation coefficient. Using the 5 most significant variables, the ACD could be predicted according to a regression formula with an accuracy of 82.1% of the predictions within 0.5 mm. When this ACD algorithm was used in retrospect in the intraocular lens (IOL) power calculation, the refractive prediction error decreased by 10% from the error associated with a previously published 4-variable algorithm and decreased 28% from the error using no individual ACD method other than the average ACD (P < .00001). The postoperative ACD was significantly correlated with and hence predictable by a 5-variable regression method incorporating the preoperative axial length, ACD, keratometry reading, lens thickness, and refraction as the most significant variables. The statistical relationship can be used to create a new ACD prediction algorithm to incorporate in a modern "thick lens" IOL power calculation formula with significant improvement in the accuracy of the refractive predictions as a result.
                Bookmark

                Author and article information

                Journal
                J Ophthalmol
                JOP
                Journal of Ophthalmology
                Hindawi Publishing Corporation
                2090-004X
                2090-0058
                2012
                19 January 2012
                : 2012
                : 430249
                Affiliations
                1Methodist Eye Associates, The Methodist Hospital, Houston, TX 77030, USA
                2Department of Ophthalmology, Weill Cornell Medical College, New York, NY 10065, USA
                Author notes
                *Rahul T. Pandit: rtpandit@ 123456tmhs.org

                Academic Editor: Edward Manche

                Article
                10.1155/2012/430249
                3270446
                22315660
                ff5a5a3e-eeb5-4976-afb7-9b00c9b2f292
                Copyright © 2012 R. P. Patel and R. T. Pandit.

                This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 23 June 2011
                : 13 October 2011
                Categories
                Clinical Study

                Ophthalmology & Optometry
                Ophthalmology & Optometry

                Comments

                Comment on this article