      Products for Monitoring Glucose Levels in the Human Body With Noninvasive Optical, Noninvasive Fluid Sampling, or Minimally Invasive Technologies.

      Read this article at

          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Conventional home blood glucose measurements require a sample of blood that is obtained by puncturing the skin at the fingertip. To avoid the pain associated with this procedure, there is high demand for medical products that allow glucose monitoring without blood sampling. In this review article, all such products are presented.

          Related collections

          Most cited references177

          • Record: found
          • Abstract: found
          • Article: not found

          2. Classification and Diagnosis of Diabetes: Standards of Medical Care in Diabetes—2021

          (2020)
          The American Diabetes Association (ADA) "Standards of Medical Care in Diabetes" includes the ADA's current clinical practice recommendations and is intended to provide the components of diabetes care, general treatment goals and guidelines, and tools to evaluate quality of care. Members of the ADA Professional Practice Committee, a multidisciplinary expert committee (https://doi.org/10.2337/dc21-SPPC), are responsible for updating the Standards of Care annually, or more frequently as warranted. For a detailed description of ADA standards, statements, and reports, as well as the evidence-grading system for ADA's clinical practice recommendations, please refer to the Standards of Care Introduction (https://doi.org/10.2337/dc21-SINT). Readers who wish to comment on the Standards of Care are invited to do so at professional.diabetes.org/SOC.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Photoplethysmography and its application in clinical physiological measurement

            John Allen (2007)
            Physiological Measurement, 28(3), R1-R39
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Flash Glucose-Sensing Technology as a Replacement for Blood Glucose Monitoring for the Management of Insulin-Treated Type 2 Diabetes: a Multicenter, Open-Label Randomized Controlled Trial

              Introduction Glycemic control in participants with insulin-treated diabetes remains challenging. We assessed safety and efficacy of new flash glucose-sensing technology to replace self-monitoring of blood glucose (SMBG). Methods This open-label randomized controlled study (ClinicalTrials.gov, NCT02082184) enrolled adults with type 2 diabetes on intensive insulin therapy from 26 European diabetes centers. Following 2 weeks of blinded sensor wear, 2:1 (intervention/control) randomization (centrally, using biased-coin minimization dependant on study center and insulin administration) was to control (SMBG) or intervention (glucose-sensing technology). Participants and investigators were not masked to group allocation. Primary outcome was difference in HbA1c at 6 months in the full analysis set. Prespecified secondary outcomes included time in hypoglycemia, effect of age, and patient satisfaction. Results Participants (n = 224) were randomized (149 intervention, 75 controls). At 6 months, there was no difference in the change in HbA1c between intervention and controls: −3.1 ± 0.75 mmol/mol, [−0.29 ± 0.07% (mean ± SE)] and −3.4 ± 1.04 mmol/mol (−0.31 ± 0.09%) respectively; p = 0.8222. A difference was detected in participants aged <65 years [−5.7 ± 0.96 mmol/mol (−0.53 ± 0.09%) and −2.2 ± 1.31 mmol/mol (−0.20 ± 0.12%), respectively; p = 0.0301]. Time in hypoglycemia <3.9 mmol/L (70 mg/dL) reduced by 0.47 ± 0.13 h/day [mean ± SE (p = 0.0006)], and <3.1 mmol/L (55 mg/dL) reduced by 0.22 ± 0.07 h/day (p = 0.0014) for intervention participants compared with controls; reductions of 43% and 53%, respectively. SMBG frequency, similar at baseline, decreased in intervention participants from 3.8 ± 1.4 tests/day (mean ± SD) to 0.3 ± 0.7, remaining unchanged in controls. Treatment satisfaction was higher in intervention compared with controls (DTSQ 13.1 ± 0.50 (mean ± SE) and 9.0 ± 0.72, respectively; p < 0.0001). No serious adverse events or severe hypoglycemic events were reported related to sensor data use. Forty-two serious events [16 (10.7%) intervention participants, 12 (16.0%) controls] were not device-related. Six intervention participants reported nine adverse events for sensor-wear reactions (two severe, six moderate, one mild). Conclusion Flash glucose-sensing technology use in type 2 diabetes with intensive insulin therapy results in no difference in HbA1c change and reduced hypoglycemia, thus offering a safe, effective replacement for SMBG. Trial registration ClinicalTrials.gov identifier: NCT02082184. Funding Abbott Diabetes Care. Electronic supplementary material The online version of this article (doi:10.1007/s13300-016-0223-6) contains supplementary material, which is available to authorized users.
                Bookmark

                Author and article information

                Journal
                J Diabetes Sci Technol
                Journal of diabetes science and technology
                SAGE Publications
                1932-2968
                1932-2968
                Jan 2022
                : 16
                : 1
                Affiliations
                [1 ] Diabetes Technology Society, Burlingame, California, USA.
                [2 ] AGDT (Working group of Diabetes Technology), Germany, Ulm, Germany.
                [3 ] University of Iowa, Department of Chemistry, Iowa City, Iowa, USA.
                [4 ] Foundation for Innovative New Diagnostics, Geneva, Switzerland.
                [5 ] Science Consulting in Diabetes GmbH, Neuss, Germany.
                [6 ] Mills-Peninsula Medical Center, San Mateo, California, USA.
                Article
                10.1177/19322968211007212
                8721558
                34120487
                8966ae95-9918-4a8b-8758-f1a5623cb33a
                History

                fluid sampling,glucose,invasive,minimally invasive,noninvasive,optical

                Comments

                Comment on this article