      Respiration rate and volume measurements using wearable strain sensors

      Read this article at

          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Current methods for continuous respiration monitoring such as respiratory inductive or optoelectronic plethysmography are limited to clinical or research settings; most wearable systems reported only measures respiration rate. Here we introduce a wearable sensor capable of simultaneously measuring both respiration rate and volume with high fidelity. Our disposable respiration sensor with a Band-Aid© like formfactor can measure both respiration rate and volume by simply measuring the local strain of the ribcage and abdomen during breathing. We demonstrate that both metrics are highly correlated to measurements from a medical grade continuous spirometer on participants at rest. Additionally, we also show that the system is capable of detecting respiration under various ambulatory conditions. Because these low-powered piezo-resistive sensors can be integrated with wireless Bluetooth units, they can be useful in monitoring patients with chronic respiratory diseases in everyday settings.

          Related collections

          Most cited references21

          • Record: found
          • Abstract: found
          • Article: not found

          A concordance correlation coefficient to evaluate reproducibility.

          L Lin (1989)
          A new reproducibility index is developed and studied. This index is the correlation between the two readings that fall on the 45 degree line through the origin. It is simple to use and possesses desirable properties. The statistical properties of this estimate can be satisfactorily evaluated using an inverse hyperbolic tangent transformation. A Monte Carlo experiment with 5,000 runs was performed to confirm the estimate's validity. An application using actual data is given.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnea in adult patients. Portable Monitoring Task Force of the American Academy of Sleep Medicine.

              Based on a review of literature and consensus, the Portable Monitoring Task Force of the American Academy of Sleep Medicine (AASM) makes the following recommendations: unattended portable monitoring (PM) for the diagnosis of obstructive sleep apnea (OSA) should be performed only in conjunction with a comprehensive sleep evaluation. Clinical sleep evaluations using PM must be supervised by a practitioner with board certification in sleep medicine or an individual who fulfills the eligibility criteria for the sleep medicine certification examination. PM may be used as an alternative to polysomnography (PSG) for the diagnosis of OSA in patients with a high pretest probability of moderate to severe OSA. PM is not appropriate for the diagnosis of OSA in patients with significant comorbid medical conditions that may degrade the accuracy of PM. PM is not appropriate for the diagnostic evaluation of patients suspected of having comorbid sleep disorders. PM is not appropriate for general screening of asymptomatic populations. PM may be indicated for the diagnosis of OSA in patients for whom in-laboratory PSG is not possible by virtue of immobility, safety, or critical illness. PM may also be indicated to monitor the response to non-CPAP treatments for sleep apnea. At a minimum, PM must record airflow, respiratory effort, and blood oxygenation. The airflow, effort, and oximetric biosensors conventionally used for in-laboratory PSG should be used in PM. The Task Force recommends that PM testing be performed under the auspices of an AASM-accredited comprehensive sleep medicine program with written policies and procedures. An experienced sleep technologist/technician must apply the sensors or directly educate patients in sensor application. The PM device must allow for display of raw data with the capability of manual scoring or editing of automated scoring by a qualified sleep technician/technologist. A board certified sleep specialist, or an individual who fulfills the eligibility criteria for the sleep medicine certification examination, must review the raw data from PM using scoring criteria consistent with current published AASM standards. Under the conditions specified above, PM may be used for unattended studies in the patient's home. Afollow-up visit to review test results should be performed for all patients undergoing PM. Negative or technically inadequate PM tests in patients with a high pretest probability of moderate to severe OSA should prompt in-laboratory polysomnography.
                Bookmark

                Author and article information

                Journal
                npj Digital Medicine
                npj Digital Med
                Springer Science and Business Media LLC
                2398-6352
                December 2019
                February 13 2019
                December 2019
                : 2
                : 1
                Article
                10.1038/s41746-019-0083-3
                45565070-c5b4-480b-81ed-21c4ac5a14ce
                © 2019

                http://creativecommons.org/licenses/by/4.0

                History

                Comments

                Comment on this article