      Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state.

      1 , ,
      Magnetic resonance in medicine
      Wiley

      Read this article at

      ScienceOpenPublisherPubMed
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A novel, fully 3D, high-resolution T(1) and T(2) relaxation time mapping method is presented. The method is based on steady-state imaging with T(1) and T(2) information derived from either spoiling or fully refocusing the transverse magnetization following each excitation pulse. T(1) is extracted from a pair of spoiled gradient recalled echo (SPGR) images acquired at optimized flip angles. This T(1) information is combined with two refocused steady-state free precession (SSFP) images to determine T(2). T(1) and T(2) accuracy was evaluated against inversion recovery (IR) and spin-echo (SE) results, respectively. Error within the T(1) and T(2) maps, determined from both phantom and in vivo measurements, is approximately 7% for T(1) between 300 and 2000 ms and 7% for T(2) between 30 and 150 ms. The efficiency of the method, defined as the signal-to-noise ratio (SNR) of the final map per voxel volume per square root scan time, was evaluated against alternative mapping methods. With an efficiency of three times that of multipoint IR and three times that of multiecho SE, our combined approach represents the most efficient of those examined. Acquisition time for a whole brain T(1) map (25 x 25 x 10 cm) is less than 8 min with 1 mm(3) isotropic voxels. An additional 7 min is required for an identically sized T(2) map and postprocessing time is less than 1 min on a 1 GHz PIII PC. The method therefore permits real-time clinical acquisition and display of whole brain T(1) and T(2) maps for the first time.

          Related collections

          Author and article information

          Journal
          Magn Reson Med
          Magnetic resonance in medicine
          Wiley
          0740-3194
          0740-3194
          Mar 2003
          : 49
          : 3
          Affiliations
          [1 ] Imaging Research Laboratories, Robarts Research Institute, London, Ontario, Canada.
          Article
          10.1002/mrm.10407
          12594755
          e9e8516e-7a69-4404-becd-7e4d777e779c
          Copyright 2003 Wiley-Liss, Inc.
          History

          Comments

          Comment on this article