16
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Grado de fiabilidad de la evaluación del análisis de Bolton en modelos virtuales tridimensionales versus modelos de yeso. una revisión Translated title: Degree of reliability of the assessment of the Bolton analysis in three-dimensional virtual models versus plaster models. a review

      review-article
      1 , * , , 1
      Revista Científica Odontológica
      Universidad Científica del Sur
      modelos virtuales, modelos de yeso, Bolton, fiabilidad, virtual models, plaster models, Bolton, reliability

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          RESUMEN

          Introducción:

          El análisis de Bolton se emplea para determinar anomalías con respecto a la masa dentaria, con fines de diagnóstico y planificación del tratamiento, la posibilidad de utilizar un método digital, que fue introducido y probado para medir el tamaño del diente mesiodistal, es una alternativa atractiva; además, la creciente aceptación de la tecnología dental digital, generó que los modelos de estudio digitales se vuelvan populares en entorno a la ortodoncia.

          Objetivo:

          evaluar el grado de fiabilidad de la evaluación del análisis de Bolton en modelos virtuales tridimensionales versus modelos de yeso por medio de una revisión de la literatura.

          Materiales y métodos:

          Se realizó una búsqueda en las principales bases de datos de la literatura científica internacional sobre ciencias de la salud: Medline, a través de PubMed, SciELO, Lilacs, Embase. Se incluyeron artículos de revisión publicados entre el año 2000 hasta octubre 2021.

          Resultados:

          El escáner de sobremesa fue la mejor opción para la digitalización de modelos dentales, pero esto no quita mérito alguno al CBCT y al escáner láser intraoral, que siguen siendo una opción asequible válida para la digitalización de modelos 3D con resultados que se encuentran dentro del rango “clínicamente aceptable”.

          Conclusiones:

          Los modelos digitales 3D generados con escáneres intraorales y escáneres extraorales son confiables y precisos en comparación con las impresiones convencionales y ahorran tiempo. En la mayoría de los casos, se hallaron diferencias estadísticamente significativas, pero de poca relevancia clínica.

          ABSTRACT

          Introduction:

          Bolton analysis is used to determine anomalies with respect to the dental mass, for diagnosis and treatment planning purposes, the possibility of using a digital method was introduced and tested to measure the size of the mesiodistal tooth. In this way, digital dental technology has made digital study models become popular in orthodontics.

          Objective:

          to evaluate the degree of reliability of the evaluation of the Bolton analysis in three-dimensional virtual models versus plaster models through a review of the literature.

          Materials and methods:

          A search was carried out in the primary databases of the international scientific literature on health sciences: Medline, through PubMed, SciELO, Lilacs, and Embase. Review articles published between the year 2000 and October 2021 were included.

          Results:

          The desktop scanner was the best option for digitizing dental models, but this does not detract from CBCT and intraoral laser scanners, which are still an option. Reasonable validity for digitizing 3D models with results within the "clinically acceptable" range was found.

          Conclusions:

          3D digital models generated with intraoral and extraoral scanners are reliable and accurate compared to conventional impressions and save time, in most cases statistically significant differences were found, but of little clinical relevance.

          Related collections

          Most cited references42

          • Record: found
          • Abstract: found
          • Article: not found

          Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner.

          Digital impression devices are used alternatively to conventional impression techniques and materials. The aims of this study were to evaluate the precision of digital intraoral scanning under clinical conditions (iTero; Align Technologies, San Jose, Calif) and to compare it with the precision of extraoral digitization.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Evaluation of the accuracy of 7 digital scanners: An in vitro analysis based on 3-dimensional comparisons.

            As digital impressions become more common and more digital impression systems are released onto the market, it is essential to systematically and objectively evaluate their accuracy.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions.

              Digital 3-dimensional models are widely used for orthodontic diagnosis. The aim of this study was to assess the validity, reliability, and reproducibility of digital models obtained from the Lava Chairside Oral scanner (3M ESPE, Seefeld, Germany) and cone-beam computed tomography scans of alginate impressions for tooth-width measurements and the Bolton analysis.
                Bookmark

                Author and article information

                Contributors
                Role: Role: Role:
                Role: Role: Role:
                Journal
                Rev Cient Odontol (Lima)
                Rev Cient Odontol (Lima)
                odontologica
                Revista Científica Odontológica
                Universidad Científica del Sur
                2310-2594
                2523-2754
                29 June 2023
                Apr-Jun 2023
                : 11
                : 2
                : e155
                Affiliations
                [1] original División de Ortodoncia, Universidad Científica del Sur. Lima, Perú. humbertoloma.s@hotmail.com , lozanoh77@hotmail.com normalizedUniversidad Científica del Sur orgdiv1División de Ortodoncia orgnameUniversidad Científica del Sur Lima, Peru humbertoloma.s@ 123456hotmail.com lozanoh77@ 123456hotmail.com
                Author notes
                * Autor corresponsal: Humberto Loma Salcedo humbertoloma.s@ 123456hotmail.com

                Contribución de autoría: Los autores han participado en la elaboración, la recolección de la información y la aprobación de la versión final del artículo

                Potenciales conflictos de intereses: El autor declara no tener ningún conflicto de intereses

                Author information
                https://orcid.org/0000-0002-0075-9143
                https://orcid.org/0000-0003-2382-681X
                Article
                10.21142/2523-2754-1102-2023-155
                10809974
                38288455
                ecd6ad01-2383-44e9-b2bc-f0d257f78890

                Este es un artículo publicado en acceso abierto bajo una licencia Creative Commons

                History
                : 08 April 2023
                : 31 May 2023
                Page count
                Figures: 1, Tables: 1, Equations: 0, References: 50, Pages: 0
                Categories
                Artículo De Revisión

                modelos virtuales,modelos de yeso,bolton,fiabilidad,virtual models,plaster models,reliability

                Comments

                Comment on this article