      Theory and application of array coils in MR spectroscopy

      ,
      NMR in Biomedicine
      Wiley

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The theory and application of array coils are reviewed in the context of phased array spectroscopy. The optimization of the signal-to-noise ratio from an array of coils is developed by considering the efficiency of a phased array transmit coil. This approach avoids the need to consider noise correlation, and should be useful in future considerations of transmit phased array coils for MR spectroscopy. Methods to characterize array coil performance, including fields and coupling are briefly summarized, along with methods to minimize the effects of mutual inductance. The signal-to-noise advantages of array coils over single coils are examined for both planar and cylindrical arrays. Numerical simulations of planar arrays of 2 x 2, 4 x 4 and 8 x 8 elements and constant overall dimension are compared to a single coil of the same size. The results demonstrate a significant improvement in sensitivity near the array coil. Although the benefits of the array decrease as a function of distance from the array, the array sensitivity never drops below that of a single coil with the same overall dimensions, or that of a single element of the array. Similar results are obtained for a sixteen element cylindrical array, which is compared to a standard quadrature birdcage coil using both computational methods and phantom measurements. The phased array techniques reviewed are demonstrated with proton spectroscopic images of the brain.

          Related collections

          Most cited references57

          • Record: found
          • Abstract: found
          • Article: not found

          The intrinsic signal-to-noise ratio in NMR imaging.

          The fundamental limit for NMR imaging is set by an intrinsic signal-to-noise ratio (SNR) for a particular combination of rf antenna and imaging subjects. The intrinsic SNR is the signal from a small volume of material in the sample competing with electrical noise from thermally generated, random noise currents in the sample. The intrinsic SNR has been measured for a number of antenna-body section combinations at several different values of the static magnetic field and is proportional to B0. We have applied the intrinsic and system SNR to predict image SNR and have found satisfactory agreement with measurements on images. The relationship between SNR and pixel size is quite different in NMR than it is with imaging modalities using ionizing radiation, and indicates that the initial choice of pixel size is crucial in NMR. The analog of "contrast-detail-dose" plots for ionizing radiation imaging modalities is the "contrast-detail-time" plot in NMR, which should prove useful in choosing a suitable pixel array to visualize a particular anatomical detail for a given NMR receiving antenna.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Optimization of directivity and signal-to-noise ratio of an arbitrary antenna array

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              High frequency volume coils for clinical NMR imaging and spectroscopy.

              A tuned transmission line resonator has been developed in theory and in practical design for the clinical NMR volume coil application at 4.1 tesla. The distributed circuit transmission line resonator was designed for high frequency, large conductive volume applications where conventional lumped element coil designs perform less efficiently. The resonator design has made use of a resonant coaxial cavity, which could be variably tuned to the Larmor frequency of interest by tunable transmission line elements. Large head- and body-sized volumes, high efficiencies, and broad tuning ranges have been shown to be characteristic of the transmission line resonator to frequencies of 500 MHz. The B1 homogeneity of the resonator has been demonstrated to be a function of the electromagnetic properties of the load itself. By numerically solving Maxwell's equations for the fully time-dependent B1 field, coil homogeneity was predicted with finite-element models of anatomic structure, and inhomogeneities corrected for. A how-to exposition of coil design and construction has been included. Simple methods of quadrature driving and double tuning the transmission line resonator have also been presented. Human head images obtained with a tuned transmission line resonator at 175 MHz have clearly demonstrated uncompromised high field advantages of signal-to-noise and spatial resolution.
                Bookmark

                Author and article information

                Journal
                NMR in Biomedicine
                NMR Biomed.
                Wiley
                0952-3480
                1099-1492
                December 1997
                December 1997
                : 10
                : 8
                : 394-410
                Article
                10.1002/(SICI)1099-1492(199712)10:8<394::AID-NBM494>3.0.CO;2-0
                9542737
                e84eb8f7-1903-432e-b23f-1ed44642f84c
                © 1997

                http://doi.wiley.com/10.1002/tdm_license_1.1

                History

                Comments

                Comment on this article