4
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Microaneurysm detection in color eye fundus images for diabetic retinopathy screening.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Diabetic retinopathy (DR) is a diabetes complication, which in extreme situations may lead to blindness. Since the first stages are often asymptomatic, regular eye examinations are required for an early diagnosis. As microaneurysms (MAs) are one of the first signs of DR, several automated methods have been proposed for their detection in order to reduce the ophthalmologists' workload. Although local convergence filters (LCFs) have already been applied for feature extraction, their potential as MA enhancement operators was not explored yet. In this work, we propose a sliding band filter for MA enhancement aiming at obtaining a set of initial MA candidates. Then, a combination of the filter responses with color, contrast and shape information is used by an ensemble of classifiers for final candidate classification. Finally, for each eye fundus image, a score is computed from the confidence values assigned to the MAs detected in the image. The performance of the proposed methodology was evaluated in four datasets. At the lesion level, sensitivities of 64% and 81% were achieved for an average of 8 false positives per image (FPIs) in e-ophtha MA and SCREEN-DR, respectively. In the last dataset, an AUC of 0.83 was also obtained for DR detection.

          Related collections

          Author and article information

          Journal
          Comput Biol Med
          Computers in biology and medicine
          Elsevier BV
          1879-0534
          0010-4825
          November 2020
          : 126
          Affiliations
          [1 ] Institute for Systems and Computer Engineering, Technology and Science, Campus da Faculdade de Engenharia da Universidade Do Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal; Faculty of Engineering of the University of Porto, Rua Dr. Roberto Frias, S/n 4200-465, Porto, Portugal. Electronic address: tania.f.melo@inesctec.pt.
          [2 ] Institute for Systems and Computer Engineering, Technology and Science, Campus da Faculdade de Engenharia da Universidade Do Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal; Faculty of Engineering of the University of Porto, Rua Dr. Roberto Frias, S/n 4200-465, Porto, Portugal.
          Article
          S0010-4825(20)30326-7
          10.1016/j.compbiomed.2020.103995
          33007620
          cc863fb8-795e-4b5c-80f9-f08a3d9a486b
          Copyright © 2020 Elsevier Ltd. All rights reserved.
          History

          Sliding band filter,Diabetic retinopathy screening,Fundus image analysis,Microaneurysm detection

          Comments

          Comment on this article