20
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Visual improvement and regeneration of retinal layers in eyes with small, medium, and large idiopathic full-thickness macular holes treated with the inverted internal limiting membrane flap technique over a period of 12 months

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose

          This study aims to compare the improvement of best-corrected visual acuity (BCVA) and the reduction in defect length of external limiting membrane (ELM) and ellipsoid zone (EZ) in small ( \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$<$$\end{document} 250 μm), medium ( \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\ge$$\end{document} 250 μm), and large ( \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\ge$$\end{document} 400 μm) full-thickness macular holes (FTMH) treated with inverted internal limiting membrane (I-ILM) flap technique over a follow-up period of 12 months.

          Methods

          Ninety-one eyes of 87 patients were enrolled in this retrospective study. BCVA and spectral-domain optical coherence tomography (SD-OCT) were conducted preoperatively as well as after 1, 3, 6, 9, and 12 months postoperatively. The defect length of the ELM and the EZ was measured using the caliper tool at each follow-up time point.

          Results

          BCVA improved significantly in the group of small, medium, and large FTMH over the time of 12 months, whereby the improvement did not depend on FTMH size over 9 months. Only after 12 months, large FTMH showed significantly higher BCVA improvement compared to small and medium FTMH. The closure rate was 100% (91/91). The defect length of ELM and EZ reduced continuously over the period of 12 months. There was a significant correlation between defect length of ELM and EZ with postoperative BCVA.

          Conclusion

          The I-ILM flap technique has very good morphological and functional outcomes in small, medium, and large FTMH over a long-time period, indicating that it can be considered as a treatment option in small and medium FTMH. The defect length of ELM and EZ is directly connected to postoperative BCVA.

          Related collections

          Most cited references47

          • Record: found
          • Abstract: found
          • Article: not found

          The International Vitreomacular Traction Study Group classification of vitreomacular adhesion, traction, and macular hole.

          The International Vitreomacular Traction Study (IVTS) Group was convened to develop an optical coherence tomography (OCT)-based anatomic classification system for diseases of the vitreomacular interface (VMI).
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Inverted internal limiting membrane flap technique for large macular holes.

            Large macular holes usually have an increased risk of surgical failure. Up to 44% of large macular holes remain open after 1 surgery. Another 19% to 39% of macular holes are flat-open after surgery. Flat-open macular holes are associated with limited visual acuity. This article presents a modification of the standard macular hole surgery to improve functional and anatomic outcomes in patients with large macular holes. A prospective, randomized clinical trial. Patients with macular holes larger than 400 μm were included. In group 1, 51 eyes of 40 patients underwent standard 3-port pars plana vitrectomy with air. In group 2, 50 eyes of 46 patients underwent a modification of the standard technique, called the inverted internal limiting membrane (ILM) flap technique. In the inverted ILM flap technique, instead of completely removing the ILM after trypan blue staining, a remnant attached to the margins of the macular hole was left in place. This ILM remnant was then inverted upside-down to cover the macular hole. Fluid-air exchange was then performed. Spectral optical coherence tomography and clinical examination were performed before surgery and postoperatively at 1 week and 1, 3, 6, and 12 months. Visual acuity and postoperative macular hole closure. Preoperative mean visual acuity was 0.12 in group 1 and 0.078 in group 2. Macular hole closure was observed in 88% of patients in group 1 and in 98% of patients in group 2. A flat-hole roof with bare retinal pigment epithelium (flat-open) was observed in 19% of patients in group 1 and 2% of patients in group 2. Mean (or median) postoperative visual acuity 12 months after surgery was 0.17 (range, 0.1-0.6) in group 1 and 0.28 (range, 0.02-0.8) in group 2 (P = 0.001). The inverted ILM flap technique prevents the postoperative flat-open appearance of a macular hole and improves both the functional and anatomic outcomes of vitrectomy for macular holes with a diameter greater than 400 μm. Spectral optical coherence tomography after vitrectomy with the inverted ILM flap technique suggests improved foveal anatomy compared with the standard surgery. Copyright © 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Macular hole size as a prognostic factor in macular hole surgery.

              In 1991 there was a series of successful closures of a macular hole after vitrectomy and membrane peeling. Today this technique has become a standard procedure. The aim of this study was to evaluate the role of optical coherence tomography in diagnosing and staging, as well as in predicting, the functional and anatomical outcome after macular hole surgery. In a prospective study 94 consecutive patients (20 male, 74 female) with a mean age of 67.6 (SD 6.0) years and a macular hole stage II (n = 8), III (n = 72), and IV (n = 14) according to the classification by Gass were examined with optical coherence tomography (OCT) before pars plana vitrectomy. Macular hole diameters were determined at the level of the retinal pigment epithelium (base diameter) and at the minimal extent of the hole (minimum diameter). Calculated hole form factor (HFF) was correlated with the postoperative anatomical success rate and best corrected visual acuity. The duration of symptoms was correlated with base and minimum diameter of the macular hole. In eyes without anatomical closure of the macular hole after one surgical approach (13/94) the base diameter (p1) and the minimum diameter (p2) were significantly larger than in cases with immediate postsurgical closure (p1 = 0.003; p2 = 0.028). There was a significant negative correlation between both the base and the minimum diameter of the hole and the postoperative visual function (p1 = 0.016; p2 = 0.002). In all patients with HFF >0.9 the macular hole was closed following one surgical procedure, whereas in eyes with HFF <0.5 anatomical success rate was 67%. Better postoperative visual outcome correlated with higher HFF (p = 0.050). There was no significant correlation between the duration of symptoms and base or minimum diameters (p1 = 0.053; p2 = 0.164), respectively. Preoperative measurement of macular hole size with OCT can provide a prognostic factor for postoperative visual outcome and anatomical success rate of macular hole surgery. The duration of symptoms did not correlate with the diameters measured. Base and minimum diameters especially seem to be of predictive value in macular hole surgery.
                Bookmark

                Author and article information

                Contributors
                nathalie.bleidissel@mri.tum.de
                Journal
                Graefes Arch Clin Exp Ophthalmol
                Graefes Arch Clin Exp Ophthalmol
                Graefe's Archive for Clinical and Experimental Ophthalmology
                Springer Berlin Heidelberg (Berlin/Heidelberg )
                0721-832X
                1435-702X
                27 April 2022
                27 April 2022
                2022
                : 260
                : 10
                : 3161-3171
                Affiliations
                [1 ]GRID grid.6936.a, ISNI 0000000123222966, Department of Ophthalmology, Klinikum rechts der Isar, , Technical University Munich (TUM), ; Ismaningerstraße 22, 81675 Munich, Germany
                [2 ]Smile Eyes Augenklinik Airport, Terminalstraße Mitte 18, 85356 Munich, Germany
                [3 ]GRID grid.411095.8, ISNI 0000 0004 0477 2585, Department of Ophthalmology, , University Hospital Munich (LMU), ; Mathildenstraße 8, 80336 Munich, Germany
                Author information
                http://orcid.org/0000-0002-0848-0630
                Article
                5676
                10.1007/s00417-022-05676-9
                9477954
                35475915
                c5f931ef-52b6-4990-8f44-ad2b5f92e35f
                © The Author(s) 2022

                Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

                History
                : 2 January 2022
                : 18 March 2022
                : 14 April 2022
                Funding
                Funded by: Technische Universität München (1025)
                Categories
                Retinal Disorders
                Custom metadata
                © Springer-Verlag GmbH Germany, part of Springer Nature 2022

                Ophthalmology & Optometry
                inverted internal limiting membrane flap technique,macular hole size,spectral‐domain optical coherence tomography,external limiting membrane,ellipsoid zone,defect length

                Comments

                Comment on this article