Patellar tendon rupture after bone–patellar tendon–bone (BTB) anterior cruciate ligament
(ACL) reconstruction is a rare but known complication. Other complications that are
more
common include anterior knee pain, pain with kneeling, and peri-incisional numbness.
When the extensor mechanism fails after a BTB harvest, it is more commonly in the
form
of a patellar fracture. The rate of patellar tendon rupture has been reported to be
about 0.25%, while patellar fractures are seen at a rate of 1.3%.
1,7,18
Patellar tendon rupture can occur either in the early postoperative period,
usually attributed to slip and fall–type injuries, or as a late manifestation by forced
eccentric contraction in a flexed knee.
4,6,8,9
A variety of reconstruction options have been reported in the literature.
2,7,10
Much of the traditionally described patellar tendon repair techniques are
difficult to apply to a harvested tendon because of the defect within the patella
and
tendon as well as the different patterns of rupture encountered in harvested tendons.
Combined with the risk of patellar fracture after BTB ACL reconstruction, the decision
to make additional drill holes through the bone before the defect has filled is met
with hesitation.
11
Hamstring tendon autografts have recently become more common as reinforcements for
patellar tendon reconstruction in native tissue.
5,16,18
The concept of preserving the distal attachment of the hamstring when
reconstructing the extensor mechanism has also shown promising results. Takazawa et
al
17
reported a technique using a transosseous tunnel at the tibial tubercle to
preserve the distal attachment of the hamstring tendons while augmenting the patellar
tendon repair in a figure-of-8 fashion.
Other secondary procedures, such as meniscal root repair during the index ACL
reconstruction, may further complicate surgical planning after patellar tendon rupture
as well as rehabilitative protocols. To date, there has not been a case report of
patellar tendon reconstruction after BTB ACL reconstruction and meniscal root repair.
This is a case example of a rupture of the patellar tendon in the early postoperative
period after BTB ACL reconstruction and meniscal root repair with use of a
semitendinosus autograft with preserved distal attachment.
Case Report
The patient was an 18-year-old male college freshman who injured his knee after a
player tackled him during his high school senior season. His examination was
significant for a grade 2B Lachman classification and a positive medial McMurray
test result. A magnetic resonance imaging (MRI) scan revealed complete tear of his
ACL as well as a complex tear of the medial meniscus involving the meniscal root.
Because of his desire to continue playing football competitively, he decided on a
BTB autograft reconstruction with meniscal repair.
The patient was brought to the operating room, and the BTB autograft was harvested
using an oscillating saw, with care taken to obtain a triangular bone block from the
patella to minimize bone loss.
14
During diagnostic knee arthroscopy, it was noted that there was complete
rupture of the medial meniscal root as well as a displaced flap tear of the medial
meniscus. The flap tear was debrided, and the meniscal root repair was completed
using a transtibial pull-out technique.
3
A second medial incision was made for the ACL reconstruction to ensure that
the tibial tunnel for the ACL would remain separate from the tibial harvest site and
the anchor from the meniscal root repair. The graft was fixed to the tibia and femur
with biocomposite interference screws. The patient had full flexion and extension,
with no impingement. The paratenon was closed with interrupted Vicryl sutures. He
was made 50% partial weightbearing with crutches in a hinged knee brace locked in
extension, and he began continuous passive motion on postoperative day 1.
At 2 weeks postoperative, his wounds had healed and he began physical therapy
focusing on range of motion; per protocol, he was to remain in a hinged brace with
crutches for weightbearing. Around 6 weeks postoperatively, he slipped on ice
without his brace or crutches and came in for evaluation because of increased pain
and ecchymosis at the operative knee. On examination, he was unable to perform a
straight leg raise. His wound remained intact but was ecchymotic. Radiographs of the
knee showed patella alta. MRI showed an intact ACL reconstruction and meniscal root
repair with complete tear of the mid- to distal portion of his patellar tendon
(Figure 1). He was
indicated for surgery to repair the ruptured patellar tendon.
Figure 1.
(A) Lateral radiograph showing the patella alta. Magnetic resonance imaging
illustrates (B) rupture of the patellar tendon with an intact anterior
cruciate ligament graft and a small medial stump attached to the tibia (C,
D) as well as the lateral tendon still attached to the patella and an intact
meniscal root repair.
The patient was taken to the operating room, where an examination under anesthesia
showed an intact ACL (Lachman test) and full range of motion. These findings,
combined with the lack of additional injury seen on MRI, led to the decision to
forgo arthroscopic examination. A midline incision was made over the patella down
to
the tibial tubercle, incorporating the incision from the initial BTB graft harvest.
The patellar tendon had ruptured in the distal substance, leaving a 23-mm stump
attached to the tibia on the medial side. The lateral side had a substantial amount
of tendon still attached to the patella. Once the scar tissue was cleared and the
patellar tendon was clearly identified, a separate medial incision was made to
harvest the semitendinosus tendon with an open-ended tendon stripper, preserving the
distal attachment to the tibia. The harvested tendon was delivered into the central
wound under soft tissue. Once the harvested tendon was stripped of muscle tissue,
a
4.0-mm drill hole was placed through the tibial tubercle below the attachment of the
patellar tendon. The harvested tendon was then brought through the drill hole from
medial to lateral and was incorporated into the proximal tendon stump in a
Pulvertaft weave fashion along the inferior border of the patella.
13
Based on preinjury MRI, it was determined that the patellar tendon length was
50 mm. Once the semitendinosus was weaved through the proximal tendon stump, it was
placed in tension until the preinjury length of 50 mm was reestablished. The
semitendinosus graft was then secured to the medial aspect of the tibia with a
4.75-mm biocomposite anchor (Figure 2). Two interrupted No. 2 FiberWire sutures were
then placed to
reinforce the Pulvertaft weave at the proximal tendon stump.
Figure 2.
(A) Intraoperative photo and (B) illustration demonstrating the described
operative technique.
At this point, to further augment the repair and directly connect the
proximal-to-distal stump, 2 double-loaded 2.3-mm all-suture anchors were placed in
the inferior pole of the patella on the medial and lateral patellar bone adjacent
to
the prior BTB harvest site. A set of sutures from each anchor was used to directly
repair the 2 stumps together in a running Krakow fashion, independent of the
autograft. The remaining sutures were used to reinforce the weave at the inferior
portion of the patella in a simple interrupted fashion. The knee was flexed from 0°
to 40° intraoperatively, and the repair held together nicely.
The patient was placed in a brace locked in extension for 3 weeks until the wound
had
fully healed. At that point, he progressed to range of motion starting at 0° to 30°.
At 6 weeks postoperatively, he advanced to 0° to 60°, then range of motion as
tolerated at 10 weeks. At the 3-month follow-up, he was no longer using a brace and
was able to actively flex to 110°. There was no extension lag. Radiographs at that
time showed maintenance of patellar tendon length that was comparable to the
uninjured side (Figure 3).
At 1-year follow-up, he continued to progress with knee flexion of 135° with no
extensor lag. MRI scans were taken to evaluate the integrity of the repair before
allowing return to sport and showed healing of the patellar tendon–augment complex
(Figure 4). He was
allowed a gradual return to sport.
Figure 3.
Three-month postoperative lateral radiographs of bilateral knees.
Figure 4.
T2 magnetic resonance images 1 year postoperatively show a healed patellar
tendon repair.
Discussion
With patellar tendon rupture after BTB autograft ACL reconstruction, goals of
operative intervention are to restore function of the extensor mechanism with little
or no extensor lag, to allow early range of motion to prevent stiffness, and to
avoid wound complications. Techniques with metal implants, such as Dall-Miles
cables, have been used to reinforce the repair to allow range of motion more quickly.
15
However, these techniques require a secondary procedure to remove the cables,
and additional drill holes are made through the patella before the central defect
has filled in. The use of hamstring autograft has been utilized previously in
patellar tendon reconstructions, given the low morbidity of the harvest and
preference of autograft over allograft tissue. Typically, this has been used in the
setting of failed patellar tendon repairs, chronic patellar tendon ruptures, or
salvage techniques where quality of the residual patellar tendon tissue is of concern.
12,18,19
Van der Bracht et al
18
showed autograft hamstring to be a strong graft that allows early
rehabilitation. The idea of using hamstring autograft when tissue augmentation is
required was applied in this case, where a surgical void in the patellar tendon
existed after BTB harvest.
The combination of hamstring autograft with all-suture anchors based in the inferior
pole of the patella created a strong reconstructed patellar tendon that allowed
early range of motion. This strength persisted, and by 3 months, the patient had
regained almost full range of motion of the operative knee with no evidence of
recurrent patella alta and was able to eventually return to sport. Additionally,
this avoided the placement of large bony tunnels in the patella and the placement
of
hardware, which can make the patient susceptible to wound complications, necessitate
removal of hardware, or increase the risk of patellar fracture.
17
Finally, this fixation method highlights the large amount of tibial bone on
the medial aspect of the tibia, through which anchors may be placed despite the
existence of bone tunnels for ACL reconstruction and/or meniscal root repair.
The fact that this is a rare injury that can present with a variety of tear patterns
makes reconstruction options difficult to study. Fortunately, advances such as
all-suture anchors allow strong bony anchoring while taking up minimal space in the
bone. This proves especially beneficial when anchoring in a patella with a
preexisting bony defect. Furthermore, maintenance of the distal insertion of the
semitendinosus autograft provides a strong biologic point of fixation, which can be
helpful when reconstructing the patellar tendon.
Conclusion
Patellar tendon rupture after ACL reconstruction with BTB can be a devastating
complication. Fortunately, it remains a rare complication. Because of the low
incidence, a gold standard technique for repair has not been established. This case
represents a successful technique of patellar tendon reconstruction with
semitendinosus autograft while maintaining the native attachment of the tendon on
the anteromedial tibia. Additionally, MRI follow-up confirms the success of this
repair technique.