11
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Automated Tilt Series Alignment and Tomographic Reconstruction in IMOD

      research-article

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Automated tomographic reconstruction is now possible in the IMOD software package, including the merging of tomograms taken around two orthogonal axes. Several developments enable the production of high-quality tomograms. When using fiducial markers for alignment, the markers to be tracked through the series are chosen automatically; if there is an excess of markers available, a well-distributed subset is selected that is most likely to track well. Marker positions are refined by applying an edge-enhancing Sobel filter, which results in a 20% improvement in alignment error for plastic-embedded samples and 10% for frozen-hydrated samples. Robust fitting, in which outlying points are given less or no weight in computing the fitting error, is used to obtain an alignment solution, so that aberrant points from the automated tracking can have little effect on the alignment. When merging two dual-axis tomograms, the alignment between them is refined from correlations between local patches; a measure of structure was developed so that patches with insufficient structure to give accurate correlations can now be excluded automatically. We have also developed a script for running all steps in the reconstruction process with a flexible mechanism for setting parameters, and we have added a user interface for batch processing of tilt series to the Etomo program in IMOD. Batch processing is fully compatible with interactive processing and can increase efficiency even when the automation is not fully successful, because users can focus their effort on the steps that require manual intervention.

          Related collections

          Author and article information

          Journal
          9011206
          1746
          J Struct Biol
          J. Struct. Biol.
          Journal of structural biology
          1047-8477
          1095-8657
          26 July 2016
          19 July 2016
          February 2017
          01 February 2018
          : 197
          : 2
          : 102-113
          Affiliations
          Department of Molecular, Cellular, and Developmental Biology, University of Colorado, Boulder, CO, 80309
          Author notes
          Correspondence to: David N. Mastronarde, Dept. of MCD Biology, University of Colorado, 347 UCB, Boulder, CO 80309, mast@ 123456colorado.edu , Phone: (303) 492-4350, Fax: (303) 492-7744
          Article
          PMC5247408 PMC5247408 5247408 nihpa805559
          10.1016/j.jsb.2016.07.011
          5247408
          27444392
          6cafc0d4-f8ff-46f9-a9ff-ab7cb3fbb647
          History
          Categories
          Article

          Automated processing,Electron tomography,Tilt series alignment,Tomographic reconstruction

          Comments

          Comment on this article