      Case report of worsening of preexisting pericardial effusion after ASD device closure: is it calamitous?

      case-report

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          Secundum-type atrial septal defects (ASD) constitute 8% to 10% of congenital heart defect. Secundum ASDs can be closed either percutaneously or surgically. However, ASD device closure has proven to be technically safe and feasible; it is not free of complications. These complications include device embolization/malposition which have been reported in 3.5% of cases, arrhythmia, and pericardial effusion in 2.6% and 0.5–1.5% respectively, device thrombus, residual shunting, and impingement of the device on the adjacent structures.

          Case presentation

          We introduce three patients with secundum ASD who had preexisting pericardial effusion, device closure was performed for them, and after the procedure, the effusion size progressed significantly. We used multimodality imaging to diagnose the cause of pericardial effusion (PE). Cardiac erosion was diagnosed in one of the patients that managed surgically. We did not found any specific procedure-related cause for worsening the pericardial effusion in the other two patients.

          Conclusion

          Several reasons include procedure-related complication and other systemic causes should be considered in patients who develop pericardial effusion after trans catheter closure of ASDs.

          Related collections

          Most cited references9

          • Record: found
          • Abstract: found
          • Article: not found

          Transcatheter device closure of atrial septal defects: a safety review.

          This review discusses the current safety issues related to U.S. Food and Drug Administration approved atrial septal defect devices and proposes a potential avenue to gather additional safety data including factors, which may be involved in device erosion.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Complications of transcatheter closure of atrial septal defects.

            Transcatheter device closure of atrial septal defects has proved to be remarkably successful, and is usually preferred by both patients and parents. But how does it compare with the gold standard of surgical closure?
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              Late complications of transcatheter atrial septal defect closure requiring urgent surgery

              Introduction Transcatheter atrial septal defect (ASD) closure has become a widely applied procedure – the recommended method of therapy in eligible patients due to the improved learning curve, cosmetic benefits and shorter recovery time [1]. Although the performance and safety of these devices appear to be reliable, certain risks and complications remain. Case reports Case 1 A 21-year-old female patient was transferred to our hospital after being diagnosed with massive pulmonary thromboembolism (PTE). Three years prior to admission, she underwent transcatheter closure of the secundum ASD with a 33 mm CardioSEAL-StarFLEX occluder (NMT Medical, Boston, MA, USA). A year ago, she was involved in a car accident and sustained significant blunt chest trauma. Transthoracic echocardiography confirmed the presence of thrombi in the right atrium and the pulmonary artery, with massive dilatation of the right ventricle and the pulmonary artery, along with severe pulmonary hypertension. Also, protrusion or dislodgement of the occluder was suspected. Her deteriorated clinical conditions warranted immediate surgery. The patient was put on a cardiopulmonary bypass (CPB) and the right atrium and the pulmonary artery were opened. Several thrombi were removed, the largest being 2 × 3 cm. The ASD occluder was identified with a thrombus attached to it and evident device-arm fracture (Figure 1). The occluder underwent almost complete healing with full endocardium covering except in the rim area. The device was removed and the ASD was repaired with a patch. Unfortunately, due to right heart failure, the patient could not be successfully weaned from the CPB, not even after an artificially created interatrial shunt, and she expired. Figure 1 A, B – Trans-esophageal echocardiography demonstrating a mass in the right atrium and detached device, C, D – intraoperative finding Although one cannot say with absolute certainty that massive PTE developed because of device-related thrombosis, it seems intuitive that blood turbulence around the protruded umbrella and device-arm fracture could have acted as a nidus for repeated thrombus formation with subsequent embolization. The occluder malfunction (fracture) was most likely the result of sustained blunt chest trauma a year prior to admission. We hypothesize that the sudden increase in intrathoracic pressure during trauma as well as direct compression on the heart generated a point of high wall stress around the occluder’s septal insertion, which may have led to device fracture and dislodgment. Case 2 A 32-year-old female patient was referred to our hospital with the diagnosis of acute aortic dissection. She complained of a sharp tearing pain in the chest and back with a loss of consciousness. A year prior to admission, she underwent ASD closure with a 26 mm Amplatzer occluder (St. Jude Medical, Minneapolis, MN, USA) in another hospital. Chest computed tomography was performed showing massive pericardial effusion and no clear origin of contrast extravasation, and no signs of intimal flap throughout the aorta. Due to a cardiac tamponade and deteriorated clinical conditions, the patient was rushed to surgery where she arrested during anesthesia induction and recovered upon pericardial incision and evacuation of 400 ml of blood. She was put on a CPB and the aortic root erosion in the region of non-coronary cusp was identified (Figure 2). No signs of other aortic pathology (dissection) were evident. The tear was sutured with two pledgeted sutures. The right atrium was opened with no signs of thrombi. The Amplatzer occluder was in close relation to the roof of the atria, and consequently the aortic root, and was undoubtedly the cause of the aortic perforation. It was extracted and the ASD was repaired with a patch. She made an uneventful recovery and was discharged home on the 8th postoperative day. Figure 2 A, B – Computerized tomography showing the position of the device and pericardial effusion, C – extraction of Amplatzer device, D – aortic root erosion, E – extracted device Discussion Transcatheter closure of ASD is the recommended method of treatment in patients with suitable defect anatomy (class I) [2, 3]. Due to inherent design properties (size, shape, material, and construction), every device is associated with a specific type of complications, which are potentially life threatening. Complications commonly associated with ASD closure device include residual shunts, embolization, device-related thrombosis, erosion and perforation of the heart, infective endocarditis, and sudden death. Perforation is the most feared complication described in the literature with the incidence of device erosion in the United States around 0.1% [4]. Perforation is most likely to happen during the first 48 h after the procedure and it is rarely manifested as a late complication. Perforation usually develops on the atrial dome and the adjacent aorta. Patients can present with haemopericardium, pericardial effusion, cardiovascular collapse, and sudden cardiac death. The U.S. Food and Drug Administration issued a warning about safety issues encountered with Amplatzer septal occluder devices stating that these devices may cause life-threatening tissue erosion inside the heart requiring immediate surgery. Several mechanisms on how the device may lead to perforation were proposed [4]. Deficient rims in vulnerable areas could increase the chance of contact between the device and the atrial wall in the same manner as the oversizing of a device. Device-related thrombosis has been reported in many series with the incidence of thrombus formation of 1.2% in ASD patients [5]. The incidence of thrombus formation is highest during the first 4 weeks after device implantation and is extremely rare after 8–12 months. The specific design of the CardioSEAL-StarFLEX device (a metallic framework with Dacron fabric) rendered them prone to thrombosis as well as stress-mediated device arm fractures. The case of late thrombus formation demonstrated in our patient occurred following major blunt chest trauma that might have led to device-arm fracture that, in turn, could have acted as a nidus for repeated thrombus formation. Specifically, the majority of thrombi were found around the rim area of the occluder (fractured wires) – an area with no complete healing and endothelialization. Usually, thrombi resolve spontaneously after anticoagulation therapy with heparin or warfarin, although some thrombi require surgical intervention, as demonstrated in our case. A longer period of surveillance after device ASD closure might be warranted in order to capture late occurrence of device malfunction, which may be associated with thromboembolic events. Conflict of interest The authors declare no conflict of interest.
                Bookmark

                Author and article information

                Contributors
                fajorfi@gmail.com
                Journal
                Egypt Heart J
                Egypt Heart J
                The Egyptian Heart Journal
                Springer Berlin Heidelberg (Berlin/Heidelberg )
                1110-2608
                2090-911X
                5 June 2021
                5 June 2021
                December 2021
                : 73
                : 50
                Affiliations
                [1 ]GRID grid.469341.d, ISNI 0000 0004 0415 3725, Shaheed Rajaei Cardiovascular Medical and Research Center, ; Tehran, Iran
                [2 ]GRID grid.411230.5, ISNI 0000 0000 9296 6873, Atherosclerosis Research Center, , Ahvaz Jundishapur University of Medical Sciences, ; Ahvaz, Iran
                Author information
                http://orcid.org/0000-0002-2085-2767
                Article
                171
                10.1186/s43044-021-00171-8
                8179864
                34089387
                683ce824-dc55-4b25-b8fc-f9ea9167c1f0
                © The Author(s) 2021

                Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

                History
                : 18 December 2020
                : 7 May 2021
                Categories
                Case Report
                Custom metadata
                © The Author(s) 2021

                atrial septal defects,congenital heart defect,septal occluder device,pericardial effusion,echocardiography

                Comments

                Comment on this article