          Abstract

          Objectives:

          This study aimed to evaluate the preoperative and postoperative changes in corneal topography, intraocular pressure (IOP), and visual acuity in patients who developed posterior capsule rupture during phacoemulsification surgery and simultaneously underwent ciliary sulcus intraocular lens (IOL) implantation and in those with intact capsular integrity who simultaneously underwent intracapsular IOL implantation and to compare these changes within and between the two groups.

          Methods:

          Among the 855 patients, 92 eyes of 69 patients whose corneal topography, IOP, and best-corrected visual acuity (BCVA) were successfully measured were included in the study. Preliminary chamber parameters [horizontal visible iris diameter (HVID), iridocorneal angle, anterior chamber volume (ACV), and anterior chamber depth (ACD)] were measured before and after surgery using a Sirius corneal topography device.

          Results:

          The IOL was implanted in the capsular bag in 58 patients and in the ciliary sulcus between the posterior iris and the capsule in 34 patients. In the sulcus IOL group, both BCVA and IOP measurements statistically significantly increased in the postoperative period compared with the preoperative values (p<0.001). As regards postoperative changes between the intracapsular and sulcus IOL groups, no significant difference was found in the changes in HVID (p=0.584), iridocorneal angle (p=0.282), and ACD (p=0.382), whereas the changes in ACV, IOP, and BCVA were statistically significantly different (p=0.020, p<0.001, and p<0.001, respectively).

          Conclusion:

          While the IOP of the sulcus IOL group significantly increased, that of the intracapsular group significantly decreased. Visual acuity increased in both lens implants, but patients with intracapsular lenses had greater improvement in visual acuity; thus, intracapsular IOL implantation was more advantageous than sulcus IOL implantation.

          Related collections

          Most cited references17

          • Record: found
          • Abstract: not found
          • Article: not found

          Age-related cataract

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Manual small incision cataract surgery (MSICS) with posterior chamber intraocular lens versus phacoemulsification with posterior chamber intraocular lens for age-related cataract.

            Age-related cataract is a major cause of blindness and visual morbidity worldwide. It is therefore important to establish the optimal technique of lens removal in cataract surgery.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Ultrasound biomicroscopic study of anterior segment changes after phacoemulsification and foldable intraocular lens implantation.

              To report quantitative changes in the anterior segment configuration after clear corneal incision phacoemulsification and foldable intraocular lens (IOL) implantation by means of ultrasound biomicroscopy (UBM). Prospective, nonrandomized, comparative (self-controlled) trial. Twenty-one eyes of 19 patients with senile or presenile cataracts and no other ocular illness. Patients were examined with UBM before and 1 and 3 months after surgery. At each UBM examination, axial images of the anterior chamber and radial sections of the angle at the superior, lateral, inferior, and medial quadrants were obtained. Central anterior chamber depth (ACD), iris-lens contact distance, iris-lens angle (ILA), angle opening distance at points 250 (AOD250) and 500 microm (AOD500) from the scleral spur, trabecular-iris angle (TIA), iris thickness 500 microm from the scleral spur (IT), trabecular-ciliary process distance (TCPD), iris-ciliary process distance (ICPD), iris-zonule distance, iris-sclera angle (ISA), and ciliary process-sclera angle (CPSA). After surgery, central anterior chamber depth was also measured from the cornea to the IOL (ACD) and from the cornea to the pupillary plane (ACD2). Each variable was measured twice in different days by the same observer. The variables IT, TCPD, ICPD, IZD, and CPSA did not significantly change after surgery (P > 0.01). Central anterior chamber depth increased approximately 30% after surgery (approximately 850 microm; P < 0.001), by both measurement methods used (ACD x ACD and ACD x ACD2). Anterior chamber angle significantly increased, by approximately 50% of the initial value, by the three measurement methods used: AOD250 (P
                Bookmark

                Author and article information

                Journal
                Beyoglu Eye J
                Beyoglu Eye J
                Beyoglu Eye Journal
                Kare Publishing (Turkey )
                2459-1777
                2587-0394
                2020
                28 December 2020
                : 5
                : 3
                : 188-193
                Affiliations
                [1 ]Department of Ophthalmology, University of Health Sciences, Antalya Training and Research Hospital, Antalya, Turkey
                [2 ]Department of Ophthalmology, University of Health Sciences, Beyoglu Eye Training and Research Hospital, Istanbul, Turkey
                [3 ]Department of Ophthalmology, Serik State Hospital, Antalya, Turkey
                [4 ]Department of Ophthalmology, Bolu State Hospital, Bolu, Turkey
                [5 ]Department of Ophthalmology, University of Health Sciences, Sancaktepe Training and Research Hospital, Istanbul, Turkey
                Author notes
                Address for correspondence: Mustafa Kalaycı, MD. Saglik Bilimleri Universitesi, Antalya Egitim ve Arastirma Hastanesi, Goz Hastaliklari Klinigi, Antalya, Turkey Phone: +90 532 728 09 63 E-mail: drkalayci07@ 123456hotmail.com
                Article
                BEJ-5-188
                10.14744/bej.2020.30301
                8784468
                35098086
                1198efd9-23a5-4ea4-b5bc-5998c2e2c9a0
                Copyright: © 2020 by Beyoglu Eye Training and Research Hospital

                This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License

                History
                : 22 September 2020
                : 24 October 2020
                Categories
                Original Article

                corneal tomography,intraocular lens,intraocular pressure,phacoemulsification surgery,visual acuity

                Comments

                Comment on this article