Inviting an author to review:
Find an author and click ‘Invite to review selected article’ near their name.
Search for authorsSearch for similar articles
107
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Intimal plus medial thickness of the arterial wall: a direct measurement with ultrasound imaging.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A study in vitro of specimens of human aortic and common carotid arteries was carried out to determine the feasibility of direct measurement (i.e., not from residual lumen) of arterial wall thickness with B mode real-time imaging. Measurements in vivo by the same technique were also obtained from common carotid arteries of 10 young normal male subjects. Aortic samples were classified as class A (relatively normal) or class B (with one or more atherosclerotic plaques). In all class A and 85% of class B arterial samples a characteristic B mode image composed of two parallel echogenic lines separated by a hypoechoic space was found. The distance between the two lines (B mode image of intimal + medial thickness) was measured and correlated with the thickness of different combinations of tunicae evaluated by gross and microscopic examination. On the basis of these findings and the results of dissection experiments on the intima and adventitia we concluded that results of B mode imaging of intimal + medial thickness did not differ significantly from the intimal + medial thickness measured on pathologic examination. With respect to the accuracy of measurements obtained by B mode imaging as compared with pathologic findings, we found an error of less than 20% for measurements in 77% of normal and pathologic aortic walls. In addition, no significant difference was found between B mode-determined intimal + medial thickness in the common carotid arteries evaluated in vitro and that determined by this method in vivo in young subjects, indicating that B mode imaging represents a useful approach for the measurement of intimal + medial thickness of human arteries in vivo.

          Related collections

          Author and article information

          Journal
          Circulation
          Circulation
          Ovid Technologies (Wolters Kluwer Health)
          0009-7322
          0009-7322
          Dec 1986
          : 74
          : 6
          Article
          10.1161/01.cir.74.6.1399
          3536154
          f1c2dac7-48d0-46ee-9216-a85d6f345506
          History

          Comments

          Comment on this article

          scite_
          0
          0
          0
          0
          Smart Citations
          0
          0
          0
          0
          Citing PublicationsSupportingMentioningContrasting
          View Citations

          See how this article has been cited at scite.ai

          scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

          Similar content28

          Cited by305