Inviting an author to review:
Find an author and click ‘Invite to review selected article’ near their name.
Search for authorsSearch for similar articles
106
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Re-examination and further development of a precise and rapid dye method for measuring cell growth/cell kill

      , ,
      Journal of Immunological Methods
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The tetrazolium salt (MTT) method involving conversion of MTT to coloured formazan by cells serving as indirect measurements of cell growth/cell kill has been reported by several groups, although technical problems have been encountered. The present investigation was undertaken in order to delineate what laboratory variables have direct influence on the sensitivity and reproducibility of the method. The pH of the extraction buffer was of the utmost importance, since it was demonstrated that a pH greater than 5 would give rise to false signals. Furthermore, modifying the composition of the extraction buffer, all formazan dye grains were solubilised, totally. A direct comparison with published methods demonstrated that only the modified method would yield 100% higher signals without increasing the background. In contrast to previous reports, it was shown that phenol red does not interfere with the measurements and no washing steps are required since all ingredients can be added subsequently. Serum proteins at concentrations up to 25% have no influence on the result. All samples can be measured in an ELISA scanner at 570 nm with little intra-assay variation.

          Related collections

          Author and article information

          Journal
          Journal of Immunological Methods
          Journal of Immunological Methods
          Elsevier BV
          00221759
          May 1989
          May 1989
          : 119
          : 2
          : 203-210
          Article
          10.1016/0022-1759(89)90397-9
          2470825
          91de910c-9ab0-45e6-94ae-d6b2108c717d
          © 1989

          https://www.elsevier.com/tdm/userlicense/1.0/

          History

          Comments

          Comment on this article

          scite_
          0
          0
          0
          0
          Smart Citations
          0
          0
          0
          0
          Citing PublicationsSupportingMentioningContrasting
          View Citations

          See how this article has been cited at scite.ai

          scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

          Similar content883

          Cited by353