Search for authorsSearch for similar articles
9
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Invasive acute hemodynamic response to guide left ventricular lead implantation predicts chronic remodeling in patients undergoing cardiac resynchronization therapy.

      Journal of the American College of Cardiology
      Aged, Cardiac Resynchronization Therapy, Cardiac Resynchronization Therapy Devices, Cardiomyopathy, Dilated, surgery, Female, Heart Failure, Humans, Male, Middle Aged, Prosthesis Implantation, methods, Treatment Outcome, Ventricular Pressure, Ventricular Remodeling

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          We evaluated the relationship between acute hemodynamic response (AHR) and reverse remodeling (RR) in cardiac resynchronization therapy (CRT). CRT reduces mortality and morbidity in heart failure patients; however, up to 30% of patients do not derive symptomatic benefit. Higher proportions do not remodel. Multicenter trials have shown echocardiographic techniques are poor at improving response rates. We hypothesized the degree of AHR at implant can predict which patients remodel. Thirty-three patients undergoing CRT (21 dilated and 12 ischemic cardiomyopathy) were studied. Left ventricular (LV) volumes were assessed before and after CRT. The AHR (maximum rate of left ventricular pressure [LV-dP/dt(max)]) was assessed at implant with a pressure wire in the LV cavity. Largest percentage rise in LV-dP/dt(max) from baseline (atrial antibradycardia pacing or right ventricular pacing with atrial fibrillation) to dual-chamber pacing (DDD)-LV was used to determine optimal coronary sinus LV lead position. Reverse remodeling was defined as reduction in LV end systolic volume ≥15% at 6 months. The LV-dP/dt(max) increased significantly from baseline (801 ± 194 mm Hg/s to 924 ± 203 mm Hg/s, p < 0.001) with DDD-LV pacing for the optimal LV lead position. The LV end systolic volume decreased from 186 ± 68 ml to 157 ± 68 ml (p < 0.001). Eighteen (56%) patients exhibited RR. There was a significant relationship between percentage rise in LV-dP/dt(max) and RR for DDD-LV pacing (p < 0.001). A similar relationship for AHR and RR in dilated cardiomyopathy and ischemic cardiomyopathy (p = 0.01 and p = 0.006) was seen. Acute hemodynamic response to LV pacing is useful for predicting which patients are likely to remodel in response to CRT both for dilated cardiomyopathy and ischemic cardiomyopathy. Using AHR has the potential to guide LV lead positioning and improve response rates. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

          Related collections

          Author and article information

          Comments

          Comment on this article

          scite_
          0
          0
          0
          0
          Smart Citations
          0
          0
          0
          0
          Citing PublicationsSupportingMentioningContrasting
          View Citations

          See how this article has been cited at scite.ai

          scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

          Similar content176

          Cited by39